Type II — High-Pressure第 140 / 240 题
A very-high-pressure appliance using R-13 must have its refrigerant recovered before service. Using recovery equipment made after November 15, 1993, what is the required evacuation level?
a.15 inches Hg vacuum
b.10 inches Hg vacuum
c.0 inches Hg (atmospheric pressure)
d.25 mm Hg absolute
解析
For very-high-pressure appliances (such as those using R-13 or R-503), the required recovery evacuation level is 0 inches Hg (atmospheric), for equipment made before or after November 15, 1993. These refrigerants have such high pressures that reaching atmospheric already removes most of the charge. The deeper 10 and 15 inches Hg levels apply to ordinary high-pressure appliances.
法律依据: 40 CFR §82.156免费刷完整 240 道题库 — 无需注册。
同考点相关题目
- A technician plans to retrofit an old R-22 system to an HFC blend that uses polyolester (POE) oil. Which statement about the retrofit is correct?
- A technician handles a high-pressure refrigerant cylinder in a hot truck bed in summer. Which practice is safest for storing and transporting the cylinder?
- A technician sets up push-pull recovery on a system with a large liquid charge. How does the push-pull method work?
- A technician measures 12°F of superheat on a fixed-orifice R-22 system but the manufacturer's chart calls for 20°F at those conditions. What does the low superheat suggest?
- During recovery from a Type II system, a technician sees noncondensable gases (air) collected in the recovery cylinder. What is the correct handling under Section 608?
- A DOT-approved refrigerant recovery cylinder must be periodically retested for safety. What is the standard hydrostatic retest interval for these cylinders?