ABO Optician — All Questions
← Back to practice100 questions
Compensated power calculations are most critical when the fitted vertex distance differs from what?
- a.The seg height
- b.The frame PD
- c.The refracted vertex distance✓
- d.The base curve
The refraction is done at a specific vertex distance; when the dispensed frame sits at a different vertex distance, the effective power shifts, so compensation restores the intended power at the eye.
A spherical equivalent of the Rx -2.00 -1.00 x 180 is what?
- a.-2.00 D
- b.-3.00 D
- c.-1.50 D
- d.-2.50 D✓
Spherical equivalent = sphere + one-half the cylinder = -2.00 + (-1.00 / 2) = -2.00 + (-0.50) = -2.50 D. It represents the average dioptric power of the lens.
When both eyes require decentration for a smaller PD than the frame, the optical centers are moved which way?
- a.Nasally (inward)✓
- b.Temporally (outward)
- c.Vertically only
- d.Not at all
When the patient's PD is smaller than the frame's distance between lens centers, the optical centers must be decentered inward (nasally) to line up with the pupils and avoid unwanted prism.
Reading an Rx that lists 'BO' after a prism value indicates the base is oriented how?
- a.Base in
- b.Base down
- c.Base out✓
- d.Base up
BO stands for base out, meaning the thick base of the prism points toward the ear (temporal side). BI means base in (toward the nose), BU base up, and BD base down.
To relieve a frame that sits too low on the face, the optician should adjust what?
- a.Increase pantoscopic tilt
- b.Widen the temples
- c.Loosen the temples
- d.Tighten or narrow the nose pads/bridge✓
If the frame slides down, narrowing or tightening the nose pads (or choosing a smaller bridge) raises the frame and improves the fit. Adjusting the bridge controls how high the frame rides.
Pantoscopic tilt refers to what?
- a.The vertical seg placement
- b.The temple bend behind the ear
- c.The bottom of the frame tilting closer to the face than the top✓
- d.The frame wrapping around the head
Pantoscopic tilt is the forward tilt in which the lower rim sits closer to the cheeks than the upper rim. A modest pantoscopic tilt aligns the optical axis with the downward gaze for reading.
If a patient complains a new progressive lens has narrow, distorted side vision, what is the most likely cause of unavoidable blur?
- a.Too much tint
- b.The AR coating
- c.A scratched lens
- d.Peripheral aberrations inherent to progressive design✓
All progressive lenses have zones of peripheral (lateral) blur and swim as a trade-off for the seamless power progression. Proper fitting minimizes but cannot fully eliminate these peripheral aberrations.
Which lens material is required for a child's everyday eyewear for safety reasons?
- a.CR-39
- b.Polycarbonate or Trivex✓
- c.Crown glass
- d.1.74 high-index
Impact-resistant materials such as polycarbonate or Trivex are strongly recommended for children because of their superior shatter resistance, protecting the eyes from injury during active play.
A patient says their bifocal segment is too high and they see the line while walking. The correct fix is to do what?
- a.Add more add power
- b.Raise the segment
- c.Lower the segment height in a remake or raise the frame✓
- d.Increase the tint
If the seg line interferes with distance walking vision, the segment sits too high; lowering the seg height (or adjusting the frame to sit higher) moves the line down out of the primary distance gaze.
MPD (monocular PD) is preferred over binocular PD because it accounts for what?
- a.Lens tint
- b.Segment width
- c.Facial asymmetry between the two eyes✓
- d.Frame color
Monocular PD measures each eye separately from the bridge center, correctly placing each optical center even when the face is asymmetric, which a single binocular PD split in half cannot do.
High-minus lenses can be made cosmetically thinner at the edge by doing what?
- a.Adding pantoscopic tilt
- b.Using a higher-index material and edge treatments like a roll and polish✓
- c.Choosing a larger frame
- d.Increasing the base curve
Higher-index materials reduce edge thickness for minus lenses, and a smaller frame plus proper decentration further reduces thickness. Rolling and polishing the edge improves the cosmetic appearance.
For a high-plus (aphakic-type) lens, choosing a smaller frame does what?
- a.Makes the lens heavier
- b.Adds prism
- c.Reduces center thickness and weight✓
- d.Increases center thickness
A smaller eye size means less lens material, reducing the thick center of a high-plus lens and lowering weight while improving cosmetics. Frame choice is a key tool for plus-lens patients.
When fitting a progressive lens, accurate fitting-cross placement is critical because what?
- a.It changes the base curve only
- b.It changes the frame color
- c.Misplacement forces the wearer to adopt awkward head postures✓
- d.It changes the tint
The fitting cross must align with the pupil in primary gaze; if it is off, the corridor and reading zone are misplaced, forcing the patient to tilt or turn the head to find clear vision.
A patient complains of temple pain behind the ears with new glasses. The best adjustment is to do what?
- a.Adjust the temple bend and length so it rests without pressure✓
- b.Add nose pads
- c.Tighten the temples further
- d.Increase wrap
Pain behind the ear usually means the temple bend starts too early or presses too hard; lengthening or repositioning the bend so it follows the ear contour relieves the pressure point.
Wrap angle (face-form) that is too aggressive on a high-powered Rx can cause what?
- a.No optical effect
- b.Better peripheral vision
- c.Lighter weight
- d.Unwanted prism and blur unless the lens is compensated✓
Excess wrap tilts the lens relative to the line of sight, inducing unwanted cylinder and prism, especially in stronger prescriptions. Compensated (wrap) lens designs correct for this tilt.
Which patient complaint most suggests the PD was measured or set too wide?
- a.Frame slides down
- b.Seg too low
- c.Temples too tight
- d.Eyestrain with a feeling of eyes being pulled outward✓
An overly wide PD places the optical centers outside the pupils, inducing base-out prism that the eyes must overcome, often felt as eyestrain or an outward pulling sensation.
A photochromic lens is a poor choice for a patient who wants dark lenses primarily where?
- a.Outdoors on a sunny day
- b.At the beach
- c.Inside a car (windshield blocks UV)✓
- d.In the snow
Because most photochromics activate with UV, and car windshields block much of the UV, the lenses stay relatively light while driving. A polarized or fixed-tint sunglass better serves in-car darkening.
Anti-reflective coating is especially recommended for which patients?
- a.Night drivers and computer users bothered by glare✓
- b.Those wanting a mirror tint
- c.Only safety-eyewear wearers
- d.Only children
AR coating cuts reflections and glare, benefiting night drivers who see haloes around lights and computer users bothered by screen and overhead reflections, improving both comfort and clarity.
To fit a frame that is too tight and leaves marks on the temples, the optician should do what?
- a.Widen the temple spread or adjust the endpieces outward✓
- b.Shorten the temples
- c.Increase the base curve
- d.Add pantoscopic tilt
When a frame grips the sides of the head too tightly, spreading the temples or adjusting the endpieces outward increases the temple width and relieves the pressure marks on the head.
A patient with a strong Rx wants the thinnest possible lens. Besides high-index material, what frame choice helps most?
- a.A small, well-centered frame matching their PD✓
- b.A thick plastic frame
- c.A large aviator
- d.A rimless mount only
A smaller frame that closely matches the patient's PD minimizes decentration and the amount of lens outside the optical center, reducing both edge thickness (minus) and center thickness (plus).
For a progressive lens, insufficient seg/fitting height (frame too shallow) causes what problem?
- a.Too much add power
- b.Not enough room for the reading zone, cutting off near vision✓
- c.Distance blur
- d.Excess prism
Progressive corridors need adequate vertical depth; if the frame's B measurement is too small, the reading portion at the bottom is cut off, leaving the wearer with inadequate near vision.
When dispensing polycarbonate, which coating is nearly always added and why?
- a.A mirror coat for style
- b.A polarized film
- c.A photochromic dye
- d.A scratch-resistant (hard) coating because polycarbonate is soft✓
Polycarbonate has a soft surface that scratches easily, so manufacturers apply a scratch-resistant hard coating to protect it. AR is also commonly added for its otherwise reflective surface.
A patient reports objects appear tilted or the floor seems to slope with new glasses that have significant cylinder. This is most likely due to what?
- a.Adaptation to new or changed cylinder axis/power✓
- b.Loose temples
- c.Wrong tint
- d.A scratched lens
Changes in cylinder power or axis alter spatial perception, and patients often notice tilting, sloping floors, or a fishbowl effect until they neurologically adapt, usually within a couple of weeks.
The vertical position for a general-wear D-segment bifocal is typically set at what landmark?
- a.The center of the pupil
- b.The eyebrow
- c.The top of the frame
- d.The lower eyelid margin (lower limbus)✓
A conventional flat-top (D) bifocal seg is usually set at the lower eyelid margin or lower limbus so it is out of the distance line of sight but reachable with a slight downward gaze.
Which combination is generally problematic when dispensing?
- a.A very high-plus lens in a large, rimless drill-mount frame✓
- b.Photochromic in a full-rim frame
- c.Polycarbonate in a safety frame
- d.AR coating on a plastic lens
A very high-plus lens has thick, heavy edges poorly suited to a large rimless drill mount, which stresses the lens at drill points and looks bulky; a smaller full-rim frame is more appropriate.
To reduce a patient's eyes appearing magnified in a high-plus lens, the optician can recommend what?
- a.An aspheric high-index lens✓
- b.A larger frame
- c.A thicker lens
- d.More pantoscopic tilt
Aspheric high-index designs flatten the lens and reduce magnification and bulge, minimizing the enlarged-eye appearance typical of high-plus lenses while keeping the lens thinner and lighter.
When adjusting metal nose pads to raise a frame on the face, the pads should be moved how?
- a.Farther apart
- b.Angled outward
- c.Closer together✓
- d.Left unchanged
Bringing the nose pads closer together makes them rest on a narrower part of the nose, which raises the frame higher on the face. Spreading them apart lowers the frame.
A patient's frame keeps sliding down despite tight nose pads. Besides the pads, which adjustment can help retention?
- a.Increase the base curve
- b.Loosen the endpieces
- c.Adjust the temple bend so it grips gently behind the ears✓
- d.Add more add power
Retention comes from both the nose and the ears; adjusting the temple bend so it curves gently behind and around the ear adds holding power. Combined with proper nose-pad fit, this stops a frame from sliding down.
A lensmeter (focimeter) is used to measure what?
- a.Corneal curvature
- b.Pupillary distance
- c.The power, axis, add, and optical center of a lens✓
- d.Frame temple length
The lensmeter reads a lens's sphere and cylinder power, cylinder axis, add power, optical center location, and any prism. It is the primary verification instrument in an optical lab and dispensary.
A pupillometer is designed to measure what?
- a.Base curve
- b.Lens power
- c.Monocular and binocular pupillary distance✓
- d.Segment height
A pupillometer measures the distance between the pupils, providing accurate monocular and binocular PD readings and can be set for distance or near, improving accuracy over a simple PD ruler.
Under FDA regulations, all dress eyewear lenses sold in the United States must be what?
- a.Impact resistant (capable of passing the drop-ball test)✓
- b.Made of glass
- c.Tinted
- d.Polarized
The FDA requires prescription and non-prescription dress lenses to be impact resistant, historically demonstrated by the drop-ball test, to protect wearers from lens shattering into the eye.FDA impact resistance
The FDA drop-ball test for impact resistance drops what onto the lens?
- a.A metal rod
- b.A rubber mallet
- c.A 5/8-inch steel ball from 50 inches✓
- d.A hammer
The drop-ball test drops a 5/8-inch (15.9 mm) steel ball weighing about 16 grams from a height of 50 inches onto the lens; the lens must not fracture to demonstrate impact resistance.FDA impact resistance
ANSI Z80.1 is the American National Standard that specifies what?
- a.Tolerances and requirements for prescription ophthalmic (dress) lenses✓
- b.Frame color standards
- c.Building fire codes
- d.Contact lens solutions
ANSI Z80.1 sets the recommended tolerances and requirements for prescription dress eyewear, including allowable deviations in power, cylinder axis, add, prism, and marking, guiding lens verification.ANSI Z80
Occupational and safety eyewear in the U.S. is governed by which standard?
- a.ANSI Z87.1✓
- b.ANSI Z80.1
- c.HIPAA
- d.FDA drop-ball only
ANSI Z87.1 sets requirements for occupational and educational personal eye protection, specifying high-impact testing and markings. Dress eyewear follows ANSI Z80.1, a different, less stringent impact standard.ANSI Z80
Safety frames and lenses that meet the high-impact standard are marked with what?
- a.Z87+ (the plus indicating high impact)✓
- b.FDA
- c.AR
- d.Z80
Under ANSI Z87.1, high-impact-rated safety eyewear is marked 'Z87+', where the plus sign denotes passing the high-velocity and high-mass impact tests; basic-impact eyewear is marked 'Z87' without the plus.ANSI Z80
Under HIPAA, a patient's prescription and health information must be handled how?
- a.Discarded openly
- b.Posted publicly
- c.Kept private and disclosed only as permitted✓
- d.Shared with any vendor
HIPAA requires that protected health information, including a patient's optical prescription and records, be kept confidential and disclosed only to authorized parties or as the patient permits.HIPAA
A distometer is used to measure what?
- a.Frame width
- b.Vertex distance from the cornea to the back of the lens✓
- c.Pupillary distance
- d.Lens power
A distometer measures the vertex distance between the front of the eye and the back surface of the lens, information needed for accurate power compensation in higher prescriptions.
Professional ethics require an optician who discovers a possible prescription error to do what?
- a.Refuse all service
- b.Fill it as written without comment
- c.Change the Rx independently
- d.Verify with the prescriber before dispensing✓
Ethical and safe practice requires the optician to confirm a questionable or seemingly erroneous prescription with the prescribing doctor rather than guessing or unilaterally altering it, protecting the patient.
A Geneva lens clock (lens measure) reads what?
- a.Pupillary distance
- b.Lens power in the eye
- c.Surface curvature (base curve) of a lens✓
- d.Prism amount
A lens clock, or Geneva lens measure, uses three pins to measure the sag of a lens surface and reports the surface curve in diopters, commonly used to check base curve and detect warpage.
When cleaning and handling patient frames and instruments, an optician maintains professionalism by doing what?
- a.Following sanitation and equipment-calibration routines✓
- b.Ignoring hygiene
- c.Reusing dirty cloths
- d.Skipping calibration
Regular sanitation of tools and frames and periodic calibration of instruments such as the lensmeter and pupillometer ensure accurate measurements and hygienic, professional service to patients.
Using Prentice's rule, how much prism is induced when a +4.00 D lens is decentered 5 mm?
- a.1.0 prism diopter
- b.0.5 prism diopters
- c.2.0 prism diopters✓
- d.20 prism diopters
Prentice's rule: prism (prism diopters) = decentration (cm) x power (D). 5 mm = 0.5 cm; 0.5 x 4.00 = 2.0 prism diopters.
A -6.00 D lens must produce 3 prism diopters. How far must it be decentered (Prentice's rule)?
- a.18 cm
- b.3 cm
- c.0.5 cm (5 mm)✓
- d.6 cm
Decentration = prism / power = 3 / 6.00 = 0.5 cm, which equals 5 mm of decentration from the optical center.
Transpose -1.75 +1.25 x 060 to minus-cylinder form.
- a.-0.50 +1.25 x 150
- b.-1.75 -1.25 x 060
- c.-3.00 -1.25 x 060
- d.-0.50 -1.25 x 150✓
New sphere = -1.75 + 1.25 = -0.50; change cylinder sign to -1.25; rotate axis 90 degrees (060 to 150). Result: -0.50 -1.25 x 150.
A frame has an A measurement of 52 mm, DBL of 18 mm, and the patient's PD is 62 mm. What is the total decentration for both lenses combined?
- a.8 mm total (4 mm per lens)✓
- b.0 mm
- c.16 mm per lens
- d.8 mm per lens
Frame PD (geometric center distance) = A + DBL = 52 + 18 = 70 mm. Total decentration = frame PD - patient PD = 70 - 62 = 8 mm total, split as 4 mm per lens.
With a 34 mm effective diameter and 4 mm per-lens decentration, what is the approximate minimum blank size?
- a.34 mm
- b.About 42 mm✓
- c.30 mm
- d.52 mm
A common working rule for minimum blank size is effective diameter + (2 x per-lens decentration). 34 + (2 x 4) = 42 mm, before adding any small manufacturing tolerance.
A patient is refracted at a 12 mm vertex with -10.00 D, but the frame sits at 16 mm. Which way does the effective power change, requiring compensation?
- a.No change occurs
- b.It becomes plus power
- c.Toward more minus, so less minus is ordered
- d.The lens must gain minus power✓
Moving a minus lens farther from the eye (12 to 16 mm) increases its effective minus power, so a slightly weaker (less minus) lens is ordered to keep the correction accurate at the new vertex distance.
What is the combined horizontal prism when the right lens gives 2 prism diopters base out and the left lens gives 1 prism diopter base out?
- a.3 prism diopters base out total✓
- b.0 prism diopters
- c.1 prism diopter base out total
- d.2 prism diopters base in
Horizontal prisms of the same base direction in the two eyes add together. 2 base out + 1 base out = 3 prism diopters base out total split across the two eyes.
Compute the spherical equivalent of +3.00 -2.00 x 090.
- a.+5.00 D
- b.+2.00 D✓
- c.+4.00 D
- d.+1.00 D
Spherical equivalent = sphere + (cylinder / 2) = +3.00 + (-2.00 / 2) = +3.00 + (-1.00) = +2.00 D.
How much vertical prism imbalance exists if the reading point is 8 mm below the OC in a +2.50 D right lens and a +1.00 D left lens (Prentice's rule)?
- a.0.8 prism diopters
- b.0 prism diopters
- c.1.2 prism diopters✓
- d.3.5 prism diopters
Each eye's prism = 0.8 cm x power. Right = 0.8 x 2.50 = 2.0; left = 0.8 x 1.00 = 0.8. Both are base-down (plus lens, below OC), so the imbalance = 2.0 - 0.8 = 1.2 prism diopters.
A lens has a front curve of +8.00 D and needs +2.00 D total power. What back curve is required (thin-lens approximation)?
- a.+6.00 D
- b.+10.00 D
- c.-6.00 D✓
- d.-2.00 D
Total power = front + back. Back = total - front = +2.00 - (+8.00) = -6.00 D. The back surface must be ground to -6.00 D to achieve the +2.00 D lens.
这门考试有多难?
ABO(American Board of Opticianry,美国验光配镜委员会)认证考试通常约 125 道选择题,2 小时,费用约 225 美元。涵盖眼镜光学、镜片、镜架与配镜。配镜师年薪中位数约 46,560 美元(BLS,2024 年 5 月)。
- 推荐学习时间
- 多数人 40-80 小时,与配镜工作经验同步进行。
- 官方公布的通过率
- 64.0% (来源未说明统计的是哪些考次) —— ABO-NCLE,2024。这是 ABO Basic Exam 的数据。ABO-NCLE 未给出考生人数,也未区分首考与重考;Advanced 考试为 52.0%,ABO Practical 为 65.0%。来源: ABO-NCLE — ABO/NCLE Basic Exam, “Eligibility & Pass Rates”
- 重点学习方向
- 眼镜光学——镜片类型、材料、处方,以及它们如何转化为一副成品眼镜。
费用与薪资为近似值,会随时间变动。上方的通过率引自旁边链接的来源,并限于该来源覆盖的期间——凡是我们尚未核实来源的,都会直接说明并且不给数字。