Alarm Installation

Installation carries the largest share of the examination. It mixes basic electricity, device selection and placement, wiring practice and the Act's rules on workmanship.

Circuits and supervision

A normally closed loop alarms when the circuit opens; normally closed contacts on a zone are wired in series and normally open devices in parallel. An end-of-line resistor placed at the last device lets the panel tell a normal loop from an open or a short. Ohm's law (current equals voltage divided by resistance) and battery capacity (current multiplied by hours) are the two calculations to know. Larger conductors reduce voltage drop on long runs.

Detectors and where they go

A magnetic contact pairs a switch with a magnet. A passive infrared detector reacts to changes in infrared energy and is most sensitive to movement across its pattern, so it is kept away from heaters and sunny windows. A microwave detector transmits energy that can pass through glass and thin walls, so its range is set to the room. Dual-technology detectors require both technologies to trip. Glass break detectors are mounted within rated range and line of sight of the glass and tested. Tamper switches and wireless check-in signals supervise the equipment itself.

Wiring practice

Alarm field wiring is generally power-limited, low-voltage wiring under the National Electrical Code. It is kept separate from power conductors, uses plenum-rated cable in air-handling spaces, is supported independently above suspended ceilings, and penetrations of fire-rated walls are firestopped. The panel transformer goes on an unswitched receptacle and is secured. Devices are installed according to the manufacturer's instructions and listing; UL 681 covers commercial burglar and holdup systems and UL 1641 residential systems.

Zones, delays and testing

Entry delay gives the user time to disarm after opening a designated door; exit delay gives time to leave, and one that is too short causes false alarms. A 24-hour zone is active whether the system is armed or not. After installation every zone is tested with the account placed on test at the monitoring center, and the purchaser is instructed in proper use.

Workmanship rules in the Act

A licensee may not knowingly install a defective system and must notify the owner of defects and honor warranty service: $1,000 for a first violation and $2,500 to $5,000 for later ones (§7599.58). Abandoning a project (§7599.49), departing from plans without consent (§7599.50), disregarding building, safety or labor laws (§7599.51) and entering premises without consent (§7599.45) are all violations.