A magnetic door contact consists of:
- a.A reed switch and a magnet✓
- b.A lens and a heat-sensing element
- c.A transmitter and a reflector
- d.A microphone and an amplifier
The magnet holds a reed switch in one state while the door is closed; opening the door changes the circuit. Lenses, microphones and reflectors belong to other detectors.
A normally closed alarm loop goes into alarm when:
- a.The circuit opens✓
- b.The circuit stays closed
- c.The siren is silenced
- d.The keypad is lit
In a closed loop, current flows through closed contacts; opening a contact or cutting the wire breaks the circuit and trips the zone.
The purpose of an end-of-line resistor is to let the panel:
- a.Charge the standby battery faster
- b.Raise the voltage on the loop
- c.Supervise the wiring for faults✓
- d.Make the siren louder
With a known resistance at the end of the loop, the panel can tell normal, open and shorted conditions apart.
An end-of-line resistor should be installed:
- a.Inside the control panel cabinet
- b.At the siren
- c.At the last device on the loop✓
- d.At the transformer terminals
A resistor at the panel supervises none of the field wiring; at the last device it supervises the whole run.
A passive infrared (PIR) detector senses:
- a.Reflected microwave energy from any object
- b.Sound at the frequency of breaking glass
- c.Changes in received infrared energy✓
- d.The opening of a magnetic field
A PIR is passive: it emits nothing and reacts to changes in heat energy across its detection pattern.
A PIR detector is most sensitive to movement that is:
- a.Outside the building
- b.Across its field of view✓
- c.Directly toward it
- d.Behind a solid wall
Crossing the detection zones produces the greatest change in received energy, so the detector is placed where an intruder would walk across the pattern.
A PIR detector should not be aimed at:
- a.A heater or window✓
- b.An interior hallway
- c.A carpeted floor
- d.A closed interior door
Rapid changes in infrared energy from heaters or sunlight can cause false alarms.
A microwave motion detector differs from a PIR because it:
- a.Emits its own energy✓
- b.Has no electronic parts
- c.Works only outdoors
- d.Detects only temperature
Microwave detectors are active devices whose energy can penetrate non-metallic materials, so range must be adjusted to the protected room.
A dual-technology detector reduces false alarms by requiring:
- a.Both technologies✓
- b.Two keypads
- c.Two control panels
- d.Two sirens
Combining PIR and microwave so that both must detect makes an alarm from a single environmental cause less likely.
An acoustic glass break detector should be:
- a.Mounted inside a closet away from the glass
- b.Mounted behind heavy drapes
- c.Left untested after mounting
- d.In range and line of sight of the glass✓
Range, obstructions and room acoustics affect performance, so the detector is placed per the manufacturer's instructions and checked with a tester.
A shock or vibration sensor mounted on glass or a wall detects:
- a.Body heat
- b.Open doors
- c.Impact✓
- d.Smoke
Shock sensors respond to vibration from an attack on the surface.
A photoelectric beam detector alarms when:
- a.Its beam is interrupted✓
- b.The battery is full
- c.The telephone rings
- d.The room temperature changes
Beam detectors protect a line; an intruder breaking the beam trips the zone.
A zone that is "supervised" means the panel:
- a.Reports the zone only once a year
- b.Powers the zone from the siren
- c.Ignores the zone when armed
- d.Monitors the zone for trouble✓
Supervision detects faults such as open wiring, tamper or a missing wireless sensor.
A tamper switch on a control cabinet or device is intended to:
- a.Reset the system's clock
- b.Dim the keypad at night
- c.Report an opened cover✓
- d.Silence the siren
Tamper protection reports interference with equipment.
The plug-in transformer for a control panel should be connected to:
- a.An unswitched, secured receptacle✓
- b.A receptacle shared with a space heater
- c.An extension cord run under a rug
- d.A receptacle controlled by a wall switch
A switched outlet can cut power without anyone noticing until the battery is drained; securing the transformer prevents accidental unplugging.
The purpose of the standby battery in a control panel is to:
- a.Supervise the telephone line
- b.Increase the transformer's voltage
- c.Replace the end-of-line resistors
- d.Run the system when power fails✓
The battery supplies the system when utility power fails.
A system draws 0.5 ampere in standby and must run for 4 hours on battery. The minimum capacity, before any safety margin, is:
- a.2 ampere-hours✓
- b.8 ampere-hours
- c.4.5 ampere-hours
- d.0.125 ampere-hours
Capacity equals current multiplied by time: 0.5 A × 4 h = 2 Ah. A margin is then added.
By Ohm's law, a 12-volt circuit with a 24-ohm load draws:
- a.2 amperes
- b.288 amperes
- c.36 amperes
- d.0.5 ampere✓
Current equals voltage divided by resistance: 12 ÷ 24 = 0.5 A.
Voltage drop on a long wire run to a device is reduced by:
- a.Using a larger conductor✓
- b.Adding more devices to the run
- c.Using a smaller conductor
- d.Coiling the excess wire
Larger conductors have lower resistance. Smaller wire and added load increase the drop.
Devices on a power circuit that must each receive full supply voltage are wired in:
- a.Parallel✓
- b.A single open loop
- c.Series
- d.Reverse polarity
In parallel each device sees the supply voltage; in series the voltage divides among devices.
Normally closed contacts on a single zone loop are wired in:
- a.Series✓
- b.A power circuit
- c.Parallel
- d.Reverse polarity
In series, opening any one contact opens the loop. Normally open devices are wired in parallel.
Most burglar alarm field wiring is classified under the National Electrical Code as:
- a.Feeders
- b.Service entrance conductors
- c.Power-limited circuits✓
- d.Branch circuits for appliances
Alarm signaling circuits are power-limited circuits covered by the Code's rules for Class 2 and similar wiring.
Low-voltage alarm cable should not be run:
- a.Inside a listed cable jacket
- b.With power conductors✓
- c.Along a wall cavity
- d.Through an attic
The Code requires separation of power-limited cables from light and power conductors to prevent hazardous voltages on the alarm wiring.
Cable installed in an air-handling (plenum) ceiling space must be:
- a.Plenum-rated✓
- b.Any type if short
- c.Unjacketed
- d.Lamp cord
Plenum-rated cable has low smoke and flame spread characteristics required for air-handling spaces.
When a cable passes through a fire-rated wall, the opening must be:
- a.Enlarged for air flow
- b.Left open for future cables
- c.Firestopped as approved✓
- d.Packed with newspaper
The Code requires penetrations of fire-rated assemblies to be firestopped to maintain the rating.
Alarm cables above a suspended ceiling should be supported by:
- a.Their own structural supports✓
- b.Electrical conduit
- c.Sprinkler pipes
- d.The ceiling grid wires and tiles
The Code does not allow cables to lie on ceiling tiles or be attached to pipes or conduit not intended for that purpose.
Stapling alarm cable so tightly that the insulation is crushed can cause:
- a.Intermittent faults✓
- b.Longer battery life
- c.Faster signal speed
- d.A louder siren
Damaged insulation leads to shorts, grounds and intermittent troubles, a common cause of false alarms.
Splices in alarm wiring should be:
- a.Avoided by leaving wires loose
- b.Tight, secure and insulated✓
- c.Made only with masking tape
- d.Twisted and left bare
Poor connections corrode and loosen, producing troubles and false alarms.
A wireless sensor's "supervisory" or check-in signal lets the panel detect:
- a.The weather outside
- b.A failed transmitter✓
- c.The siren's volume
- d.The customer's passcode
Supervised wireless devices report periodically; a missed check-in creates a trouble condition.
Before final placement of a wireless sensor, the installer should:
- a.Remove its battery
- b.Paint the transmitter
- c.Mount it on a metal door without testing
- d.Test signal strength at that location✓
Radio signals are affected by distance and building materials, so signal strength is verified before mounting.
An entry delay allows the user to:
- a.Bypass every zone
- b.Leave the premises after arming
- c.Change the master code
- d.Enter and disarm before an alarm✓
Entry delay starts when the entry door opens. Exit delay governs leaving.
An exit delay that is too short most often results in:
- a.False alarms on exit✓
- b.A weaker radio signal
- c.Longer entry time
- d.Lower battery voltage
Users who cannot leave and close the door in time trip the system, a common user-caused false alarm.
An interior "follower" zone is one that:
- a.Sounds the chime only
- b.Is always instant
- c.Delayed after entry✓
- d.Is always bypassed
A follower zone along the entry path follows the entry delay; if tripped first it alarms at once.
A 24-hour zone is active:
- a.Only when the system is armed away
- b.Only during a power failure
- c.Only during business hours
- d.Whether the system is armed or disarmed✓
Panic, holdup and tamper zones are typically 24-hour zones.
The exterior siren or bell should be mounted:
- a.At ground level beside the door
- b.Inside the control cabinet
- c.High and tamper protected✓
- d.On a fence post at the street
A sounder within easy reach can be disabled; tamper protection and height reduce that risk.
Which document governs how a specific device is to be installed?
- a.The customer's color scheme
- b.The installer's personal preference
- c.A competitor's brochure
- d.The manufacturer's instructions✓
Listed equipment must be installed according to its instructions and listing.
UL 681 addresses:
- a.Burglar alarm installation✓
- b.Residential plumbing fixtures
- c.Automobile emissions
- d.Elevator maintenance
UL 681 is the standard for installing and classifying commercial burglar and holdup alarm systems.
UL 1641 addresses:
- a.Commercial kitchen hoods
- b.Residential burglar alarms✓
- c.Highway signs
- d.Gas appliance venting
UL 1641 covers residential burglar alarm system installation and classification.
After installation, the installer should:
- a.Ask the customer to test alone later
- b.Test only the keypad
- c.Test every zone and its signals✓
- d.Leave before powering up
A complete functional test, with the monitoring center on test, verifies each device and the communication path.
Before testing signals with a monitored system, the installer should:
- a.Disconnect the battery
- b.Remove the siren
- c.Call the police non-emergency line
- d.Place the account on test✓
Placing the account on test prevents a dispatch on test signals.
§7599.58 prohibits a licensee from:
- a.Testing a system
- b.Offering a warranty
- c.Training the customer
- d.Knowingly defective work✓
The section bars knowingly defective installations and requires warranty service and notice to the owner of defects.
The fine for a first violation of the defective installation rule in §7599.58 is:
- a.$2,500
- b.$1,000✓
- c.$5,000
- d.$100
§7599.58 sets $1,000 for a first violation and $2,500 to $5,000 for later ones.
A licensee who walks away from an unfinished installation without legal excuse:
- a.Is within its rights
- b.May keep the equipment
- c.Violates the Act✓
- d.Owes only a refund
§7599.49 penalizes abandoning a project, with fines of $100 and $500.
An installer needs to enter a locked suite to finish wiring and no one is present. The installer should:
- a.Wait for consent✓
- b.Force the door
- c.Enter through a window
- d.Ask a neighbor for a key
§7599.45 forbids entering premises without consent.
Grounding the control panel as the manufacturer directs helps protect against:
- a.Low signal strength
- b.Forgotten passcodes
- c.Lightning and surges✓
- d.Dead keypad lights
A proper ground gives surge energy a path away from sensitive electronics.
A zone trips at random on a windy day. A likely installation cause is:
- a.A loose door✓
- b.A new keypad
- c.A full battery
- d.A strong signal
Doors that rattle in the frame can separate a contact and magnet beyond the operating gap.
The keypad should be located:
- a.In the attic
- b.In a window facing the street
- c.Outside the front door
- d.Inside, near the entry door✓
Users must reach it within the entry delay, but codes should not be visible to someone watching from outside.
A cellular communicator is often installed because it:
- a.Requires no antenna
- b.Needs no phone line✓
- c.Cannot be supervised
- d.Needs no power
A wireless path avoids the vulnerability of an exposed telephone line.
When the installation is complete, the Act requires the company to:
- a.Train the purchaser in its use✓
- b.Leave written codes on the keypad
- c.Disable user codes
- d.Keep the manual
§7599.54 requires the agreement to state this duty, and user training is the most effective false alarm prevention step.
An installer notices existing wiring that violates the electrical code. The installer should:
- a.Tell the customer✓
- b.Hide it behind a panel
- c.Connect to it anyway
- d.Say nothing
§7599.51 penalizes disregarding building and safety laws, and §7599.58 requires notifying the owner of defects.