California Alarm Company Operator Qualified Manager Exam — All Questions
30 questions
A central monitoring station's basic function is to:
- a.Manufacture control panels
- b.Issue alarm permits
- c.Repair telephone lines
- d.Act on alarm signals✓
Operators receive signals, verify as required and notify responders or contacts.
Which signal generally receives the highest handling priority?
- a.Timer test
- b.Opening report
- c.Holdup or panic✓
- d.Low battery
Signals indicating danger to life are handled before burglary, supervisory and trouble signals.
A "timer test" signal is:
- a.An automatic check✓
- b.A burglary signal
- c.A customer complaint
- d.A holdup signal
Failure to receive a scheduled test tells the monitoring center the communication path may be down.
Opening and closing reports tell the monitoring center:
- a.The price of the system
- b.Arming and disarming times✓
- c.The weather at the site
- d.The installer's schedule
These reports support supervised schedules for commercial accounts.
Before requesting police dispatch on a burglar alarm, operators typically:
- a.Attempt verification✓
- b.Call the newspaper
- c.Call the installer's home
- d.Wait one hour
Call verification screens out user-caused alarms.
A person who answers a verification call must give:
- a.A driver's license number
- b.The correct passcode✓
- c.A credit card number
- d.A date of birth only
The passcode shows the person is authorized; a wrong or duress code results in dispatch.
When requesting dispatch, the operator gives the public safety agency:
- a.The installer's registration number
- b.The customer's passcode
- c.The system's wholesale cost
- d.The address and type of alarm✓
Dispatchers need location and alarm type; many cities require the alarm permit number.
An account's emergency contact list should be:
- a.Limited to one person
- b.Fixed at installation forever
- c.Kept current by the customer✓
- d.Shared with other customers
Outdated contacts delay verification and response.
A monitoring center receives a cancel code shortly after an alarm. The operator should:
- a.Ignore the cancel
- b.Dispatch a second time
- c.Verify, then recall✓
- d.Close the account
A proper cancel means the user disarmed; recalling dispatch saves police resources.
Monitoring records of signals and operator actions are important because they:
- a.Set the license fee
- b.Document what was done✓
- c.Serve as advertising
- d.Replace the written agreement
Accurate logs resolve disputes and show compliance.
Under §7590.2, a company that only monitors alarm systems is:
- a.A private patrol operator
- b.Exempt from the Act
- c.A locksmith
- d.An alarm company operator✓
The definition of operator includes entities that monitor alarm systems.
An employee who monitors alarm signals for a licensee is:
- a.Exempt from registration
- b.A peace officer
- c.A registered alarm agent✓
- d.A private investigator
§7590.1 lists monitoring among alarm agent duties.
A dual-path communicator provides:
- a.Two user codes
- b.A backup path✓
- c.Two transformers
- d.Two sirens
Using two paths, such as internet and cellular, improves reliability.
If the monitoring center loses its primary power, it should have:
- a.A sign on the door
- b.A plan to close until power returns
- c.Standby power for its receivers✓
- d.No need for power
Monitoring is continuous, so backup power and redundancy are essential.
An alarm agent responding to an alarm finds an open door. The safest practice is to:
- a.Stay outside and notify police✓
- b.Call the customer's competitor
- c.Lock the door and leave
- d.Search the building alone
A responder's role is to observe and report; entering risks confrontation with an intruder.
A responding alarm agent's authority to arrest is that of:
- a.A peace officer
- b.A federal agent
- c.A deputy sheriff
- d.A private person✓
Alarm agents have no police powers; Penal Code §837 governs private-person arrests.
A responding alarm agent may investigate:
- a.Any crime in the neighborhood
- b.Only incidental matters✓
- c.Employee backgrounds
- d.Civil disputes for customers
§7590.2 bars operators from investigations except those incidental to their alarm duties.
A responding agent arrives while police are on scene. The agent should:
- a.Leave without speaking
- b.Enter ahead of the officers
- c.Follow officers' directions✓
- d.Take command
Cooperation and clear identification avoid confusion and danger.
The key-holder's role after a verified alarm is to:
- a.Search for the intruder
- b.Stay unreachable
- c.Give responders access✓
- d.Reset the system from home
Key-holders give access and secure the premises after responders clear it.
A violent on-duty incident in which a dangerous weapon causes injury must be reported to the Bureau within:
- a.60 days
- b.Six months
- c.Seven days✓
- d.One year
§7599.42 sets seven days, with fines of $1,000 and $2,000 for licensees and managers and $500 for employees.
A monitoring operator receives a duress code from a keypad. The operator should:
- a.Call the premises and ask if all is well
- b.Treat it as a silent emergency✓
- c.Wait for a second signal
- d.Ignore it as user error
Duress signals indicate a user acting under threat and are handled per procedure as silent emergencies.
A runaway communicator repeatedly sends signals. The monitoring center should:
- a.Delete the account
- b.Notify the customer and service✓
- c.Ignore all signals from the city
- d.Dispatch police each time
Repeated signals indicate a malfunction needing service.
An operator may place an account on test at the request of:
- a.An identified, authorized person✓
- b.A person who knows the address only
- c.A neighbor of the customer
- d.Any caller who asks
Test status suspends dispatch, so the requester's authority must be confirmed.
In many cities, police will not respond to a burglar alarm unless:
- a.The installer is present
- b.The siren is very loud
- c.The user has a permit✓
- d.The system is new
§7592.8 recognizes local permit and verification ordinances.
Account passcodes held by the monitoring center are:
- a.Confidential to authorized persons✓
- b.Printed on invoices
- c.Posted for all staff and visitors
- d.Given to callers who know the address
Passcodes are the means of confirming authority.
When a monitored communication path fails and no test signal arrives, the center should:
- a.Notify the customer✓
- b.Assume the customer cancelled
- c.Dispatch the fire department
- d.Do nothing
A missed test means alarms may not be received.
Signals such as "trouble" or "low battery" are normally handled by:
- a.Police dispatch
- b.Fire dispatch
- c.No action
- d.A service call✓
Trouble signals indicate maintenance needs, not emergencies.
A responding alarm agent's vehicle and uniform must not:
- a.Be clean
- b.Carry a radio
- c.Look like police✓
- d.Display the company name
§7598.53 requires uniforms distinguishable from law enforcement; implying police authority misleads the public.
An operator who is unsure whether an alarm is real after verification attempts fail should:
- a.Follow account instructions✓
- b.Cancel the signal
- c.Wait for the customer to call
- d.Call a different customer
Written procedures and account instructions govern, and unresolved alarms are dispatched.
A monitoring company based outside California that monitors systems in California for California customers:
- a.Is automatically exempt
- b.Needs only a city permit
- c.Needs a patrol license
- d.Should confirm licensing✓
The Act's definition includes monitoring entities; an out-of-state monitor should confirm licensing requirements with the Bureau.