California Alarm Company Operator Qualified Manager Exam — All Questions
40 questions
The most common cause of false alarms is:
- a.Earthquakes
- b.Power surges
- c.Lightning
- d.User error✓
Industry and police data consistently attribute most false alarms to user mistakes such as wrong codes and unsecured doors.
The most effective false alarm prevention step at turnover is:
- a.Raising the siren volume
- b.Removing the keypad
- c.Hands-on user training✓
- d.Shortening every delay
Users who practice arming, disarming and cancelling make fewer errors.
A customer reports frequent false alarms from one motion detector. The technician should first:
- a.Inspect the detector's location✓
- b.Replace the control panel
- c.Tell the customer to stop arming
- d.Remove the zone permanently
Heat sources, pets, moving objects and insects are common causes that inspection reveals.
A "swinger shutdown" feature:
- a.Stops repeat alarms✓
- b.Locks the keypad
- c.Opens the garage door
- d.Doubles the exit delay
After a set number of trips the zone is shut down until the system is disarmed, limiting repeated dispatches.
An "abort window" is a short period during which:
- a.The battery charges
- b.Disarming stops the signal✓
- c.Codes can be changed
- d.The siren cannot sound
A brief transmission delay lets a user who trips the system enter a code to abort the signal.
Cross-zoning reduces false alarms by requiring:
- a.Two batteries in each panel
- b.Two zones to trip together✓
- c.Two keypads at each door
- d.Two sirens outdoors
A single faulty sensor will not cause a dispatch when a second zone must confirm.
Enhanced call verification means the monitoring center:
- a.Calls two numbers first✓
- b.Calls the police first
- c.Calls only the installer
- d.Never calls the premises
Calling the premises and then a second number, such as a cell phone, resolves many alarms without dispatch.
The ANSI/SIA CP-01 standard concerns:
- a.Electrical service sizing
- b.False alarm reduction✓
- c.Elevator recall
- d.Fire sprinkler spacing
CP-01 sets features and default settings, such as exit delays and abort windows, aimed at reducing user-caused false alarms.
An audible exit warning with a faster tone near the end helps by:
- a.Testing the telephone line
- b.Resetting the clock
- c.Charging the battery
- d.Warning that time is short✓
Progress annunciation tells the user to leave or disarm before the system arms.
A user arms the system and then re-enters within the exit time. A panel with "exit time restart" will:
- a.Disarm permanently
- b.Restart the exit delay✓
- c.Bypass all zones
- d.Send an immediate alarm
Restarting the delay gives the user time to leave again without causing an alarm.
A low battery trouble signal should be handled by:
- a.Disconnecting the trouble sounder
- b.Testing and replacing the battery✓
- c.Unplugging the transformer
- d.Ignoring it until an alarm occurs
A weak battery can cause erratic operation and failure during an outage.
Routine maintenance of an alarm system includes:
- a.Repainting the sensors
- b.Changing the account number
- c.Testing devices and battery✓
- d.Rewiring every year
Periodic testing confirms the system still detects and communicates.
A zone shows a "trouble" condition on a supervised loop with all doors closed. A likely cause is:
- a.A correct passcode
- b.A full battery
- c.A wiring fault✓
- d.A quiet siren
With an end-of-line resistor, a reading outside the normal range indicates a wiring fault.
The instrument used to measure loop resistance and voltage is a:
- a.Torque wrench
- b.Stud finder
- c.Tape measure
- d.Multimeter✓
A multimeter measures voltage, resistance and current for troubleshooting.
A normal reading on a zone with a 2,000-ohm end-of-line resistor is about:
- a.2,000 ohms✓
- b.Infinite ohms
- c.12 volts
- d.0 ohms
The meter should read the resistor's value plus a small wire resistance; zero indicates a short and infinity an open.
To find an intermittent open on a long loop, a technician can:
- a.Test each half of the loop✓
- b.Replace every device at once
- c.Raise the supply voltage
- d.Remove the resistor
Halving the circuit narrows the fault location quickly.
A service technician must leave the system:
- a.Powered down
- b.Operational and tested✓
- c.Bypassed without telling anyone
- d.On test indefinitely
The customer relies on the system; unreported bypasses leave the premises unprotected.
A zone is bypassed at the customer's request. The technician should:
- a.Hide it from the customer
- b.Document and explain it✓
- c.Remove the sensor
- d.Bypass all other zones too
The customer must understand the reduced protection, and records protect both parties.
Under §7599.58 a licensee who discovers a defect in a system it installed must:
- a.Conceal it
- b.Bill for a new system
- c.Cancel the contract
- d.Notify the owner✓
The section requires notice of defects and warranty service.
A customer remodels and adds a wall that blocks a motion detector. The company should:
- a.Re-evaluate the coverage✓
- b.Leave the detector as is
- c.Increase siren volume
- d.Shorten the entry delay
Changes to the premises alter coverage; periodic review keeps the system effective.
Duress codes should be:
- a.Explained carefully to users✓
- b.Printed on the keypad
- c.Given to visitors
- d.Set the same as the master code
A duress code sends a silent emergency signal; accidental use causes a high-priority false dispatch.
A user trips the alarm by mistake. The user should:
- a.Leave the premises quickly
- b.Disarm and call to cancel✓
- c.Wait for police to arrive
- d.Unplug the siren
Prompt cancellation with proper identification can stop or recall a dispatch.
Many local ordinances respond to repeated false alarms with:
- a.Tax credits
- b.Escalating fines✓
- c.Free equipment
- d.Longer permits
§7592.8 recognizes local false alarm ordinances, which commonly use escalating fines and non-response.
A local false alarm fine caused by the company's wiring error is:
- a.The company's responsibility✓
- b.Always the customer's
- c.The manufacturer's in every case
- d.The city's
The §7592.8 protection does not apply to false alarms attributable to operator error, improper installation or defective equipment.
Before working on a monitored system, a technician should:
- a.Call the customer's neighbors
- b.Place the account on test✓
- c.Arm the system
- d.Cut the phone line
Test status prevents dispatches from signals generated during service.
After service, the technician should:
- a.Take the account off test✓
- b.Disable communication
- c.Leave it on test for a week
- d.Change the user codes without notice
An account left on test will not be dispatched on real alarms.
Loose balloons and hanging signs cause false alarms mainly with:
- a.Transformers
- b.Glass contacts
- c.Motion detectors✓
- d.Door contacts
Moving objects in a detection pattern can trip motion detectors.
A door contact gap that is too wide should be corrected by:
- a.Realigning the contact✓
- b.Taping the door shut
- c.Adding a second keypad
- d.Bypassing the zone
The magnet must stay within the switch's operating gap as the door moves in the frame.
A service record should include:
- a.Nothing if no parts were used
- b.The technician's opinion of the customer
- c.The date, problem and work done✓
- d.The customer's passcode
Service records document the system's history and the company's diligence.
A customer changes telephone service to an internet-based line. The company should:
- a.Remove the battery
- b.Assume nothing changed
- c.Cancel monitoring
- d.Test the alarm signals✓
Changes in telephone service can stop a dialer from communicating.
"Alarm verification" by audio or video means:
- a.The police verify the permit
- b.Checking for an actual event✓
- c.The user's code is verified
- d.The siren sounds twice
Verified alarms let operators confirm activity before requesting dispatch.
When a customer cancels service, removing or reprogramming the communicator prevents:
- a.Sensor supervision
- b.Battery charging
- c.Runaway dialing✓
- d.Keypad lighting
Equipment that keeps dialing ties up lines and receivers.
An installer adjusts a microwave detector's range so it:
- a.Passes through the front glass
- b.Covers the neighbor's suite
- c.Reaches the parking lot
- d.Covers only the protected room✓
Microwave energy passes through glass and thin walls, so excess range detects movement outside.
Rodents and insects cause false alarms most often by:
- a.Entering codes
- b.Nesting in detectors✓
- c.Chewing keypads
- d.Opening doors
Sealed detectors and pest control reduce these alarms.
A system keeps reporting AC power loss each evening. The first thing to check is whether the transformer is on:
- a.A grounded receptacle
- b.A surge protector
- c.A switched receptacle✓
- d.A dedicated circuit
A receptacle controlled by a light switch loses power whenever the switch is turned off.
Corrosion on outdoor contact terminals is prevented by:
- a.Spraying them with water
- b.Using indoor devices
- c.Leaving terminals exposed
- d.Weather-rated devices✓
Moisture causes high resistance and intermittent faults.
A user repeatedly forgets the code. The best response is:
- a.Stop service
- b.Remove the entry delay
- c.Disable the siren
- d.Retrain the user✓
Training and aids such as key fobs reduce user-caused false alarms.
A customer asks the company to claim police department approval of its system in a mailer. The company may do so only with:
- a.The customer's approval
- b.No approval at all
- c.A verbal comment from an officer
- d.Written police approval✓
§7599.55 requires written approval for such claims.
A technician who files a knowingly false service report with the employer or customer violates:
- a.The fire code only
- b.§7599.48✓
- c.A manufacturer policy only
- d.No rule
§7599.48 prohibits false reports, with fines of $100 and $500.
Warranty obligations on an installed system are:
- a.Void when the installer leaves the company
- b.To be honored as the agreement provides✓
- c.Optional after payment
- d.Void if the customer moves a chair
§7599.58 requires a licensee to provide the warranty service it agreed to.