Chapter 6 of 726% of exam

Seismic Analysis Procedures

This area tests how forces are shared among elements once the story shear is known: diaphragms, rigidity, torsion, drift and overturning.

Diaphragms: flexible and rigid

A flexible diaphragm, typical of wood sheathing, distributes load to the vertical elements by tributary area and behaves like a simply supported beam: the unit shear is the reaction divided by the diaphragm depth, and the chord force is the moment divided by the depth. A rigid diaphragm, typical of concrete slabs, distributes load in proportion to the relative rigidity of the vertical elements and must be checked for torsion (ASCE 7-16 Section 12.3.1).

Torsion

Where the centre of mass and centre of rigidity do not coincide, the story shear produces an inherent torsional moment. An accidental torsion is added by displacing the mass 5 percent of the building dimension perpendicular to the force (Section 12.8.4.2). Direct shear goes to each wall as V·Ri/ΣR, torsional shear as M·Ri·di/Σ(R·d²), and torsional shear that reduces the direct shear is ignored.

Drift, P-delta and separation

Design story drift is the difference of the amplified deflections δx = Cd·δxe/Ie at the top and bottom of the story (Section 12.8.6) and is compared with the allowable drift, a fraction of story height that depends on the system and risk category (Table 12.12-1). The stability coefficient θ checks P-delta effects, and adjacent structures must be separated enough to avoid pounding (Section 12.12.3).