California Civil Engineer: Seismic Principles — All Questions

78 questions

Seismic Analysis Procedures

A braced-frame column carries axial loads D = 120 kips, L = 60 kips (live load factor of 0.5 permitted) and QE = 45 kips from horizontal seismic forces. SDS = 1g and rho = 1. No snow. What is the maximum strength-level compression from the seismic load combination?

  • a.129 kips
  • b.219 kips
  • c.243 kips✓
  • d.249 kips

ASCE 7-16 Sections 2.3.6 and 12.4.2: 1.2D + Ev + Eh + 0.5L with Ev = 0.2 SDS D and Eh = rho QE. Pu = (1.2 + 0.2 x 1)(120) + 1(45) + 0.5(60) = 243 kips. Leaving out Ev gives 219 kips; the 1.6L factor belongs to the gravity combination, not the seismic one.

Seismic Analysis Procedures

A braced-frame column carries axial loads D = 200 kips, L = 80 kips (live load factor of 0.5 permitted) and QE = 90 kips from horizontal seismic forces. SDS = 1.2g and rho = 1.3. No snow. What is the maximum strength-level compression from the seismic load combination?

  • a.397 kips
  • b.445 kips✓
  • c.533 kips
  • d.556 kips

ASCE 7-16 Sections 2.3.6 and 12.4.2: 1.2D + Ev + Eh + 0.5L with Ev = 0.2 SDS D and Eh = rho QE. Pu = (1.2 + 0.2 x 1.2)(200) + 1.3(90) + 0.5(80) = 445 kips. Leaving out Ev gives 397 kips; the 1.6L factor belongs to the gravity combination, not the seismic one.

Seismic Analysis Procedures

A braced-frame column carries axial loads D = 85 kips, L = 30 kips (live load factor of 0.5 permitted) and QE = 60 kips from horizontal seismic forces. SDS = 0.9g and rho = 1. No snow. What is the maximum strength-level compression from the seismic load combination?

  • a.121 kips
  • b.154 kips
  • c.177 kips
  • d.192 kips✓

ASCE 7-16 Sections 2.3.6 and 12.4.2: 1.2D + Ev + Eh + 0.5L with Ev = 0.2 SDS D and Eh = rho QE. Pu = (1.2 + 0.2 x 0.9)(85) + 1(60) + 0.5(30) = 192 kips. Leaving out Ev gives 177 kips; the 1.6L factor belongs to the gravity combination, not the seismic one.

Seismic Analysis Procedures

A braced-frame column carries axial loads D = 310 kips, L = 150 kips (live load factor of 0.5 permitted) and QE = 110 kips from horizontal seismic forces. SDS = 1.1g and rho = 1.3. No snow. What is the maximum strength-level compression from the seismic load combination?

  • a.354 kips
  • b.590 kips
  • c.625 kips
  • d.658 kips✓

ASCE 7-16 Sections 2.3.6 and 12.4.2: 1.2D + Ev + Eh + 0.5L with Ev = 0.2 SDS D and Eh = rho QE. Pu = (1.2 + 0.2 x 1.1)(310) + 1.3(110) + 0.5(150) = 658 kips. Leaving out Ev gives 590 kips; the 1.6L factor belongs to the gravity combination, not the seismic one.

Seismic Analysis Procedures

A shear-wall boundary column has D = 60 kips of compression and QE = 95 kips of seismic tension. SDS = 1g, rho = 1. Using the strength-level combination that minimizes dead load, what net uplift (tension) must be resisted? (Report the magnitude; a positive value means tension.)

  • a.11.0 kips
  • b.41.0 kips
  • c.53.0 kips✓
  • d.95.0 kips

ASCE 7-16 Sections 2.3.6 and 12.4.2: 0.9D - Ev + Eh, i.e. (0.9 - 0.2 SDS)D with rho QE acting upward. (0.9 - 0.2 x 1)(60) - 1(95) = 42.0 - 95.0 = -53.0 kips, so net uplift (tension) of 53.0 kips. Using 0.9D without the vertical seismic term, or the 1.2D combination, overstates the dead load available to resist overturning.

Seismic Analysis Procedures

A shear-wall boundary column has D = 110 kips of compression and QE = 150 kips of seismic tension. SDS = 1.2g, rho = 1.3. Using the strength-level combination that minimizes dead load, what net uplift (tension) must be resisted? (Report the magnitude; a positive value means tension.)

  • a.96.0 kips
  • b.122.4 kips✓
  • c.153.0 kips
  • d.183.6 kips

ASCE 7-16 Sections 2.3.6 and 12.4.2: 0.9D - Ev + Eh, i.e. (0.9 - 0.2 SDS)D with rho QE acting upward. (0.9 - 0.2 x 1.2)(110) - 1.3(150) = 72.6 - 195.0 = -122.4 kips, so net uplift (tension) of 122.4 kips. Using 0.9D without the vertical seismic term, or the 1.2D combination, overstates the dead load available to resist overturning.

Seismic Analysis Procedures

A shear-wall boundary column has D = 40 kips of compression and QE = 30 kips of seismic tension. SDS = 0.8g, rho = 1. Using the strength-level combination that minimizes dead load, what net uplift (tension) must be resisted? (Report the magnitude; a positive value means tension.)

  • a.0.1 kips
  • b.0.2 kips
  • c.0.3 kips
  • d.0.4 kips✓

ASCE 7-16 Sections 2.3.6 and 12.4.2: 0.9D - Ev + Eh, i.e. (0.9 - 0.2 SDS)D with rho QE acting upward. (0.9 - 0.2 x 0.8)(40) - 1(30) = 29.6 - 30.0 = -0.4 kips, so net uplift (tension) of 0.4 kips. Using 0.9D without the vertical seismic term, or the 1.2D combination, overstates the dead load available to resist overturning.

Seismic Analysis Procedures

A shear-wall boundary column has D = 75 kips of compression and QE = 140 kips of seismic tension. SDS = 1g, rho = 1.3. Using the strength-level combination that minimizes dead load, what net uplift (tension) must be resisted? (Report the magnitude; a positive value means tension.)

  • a.129.5 kips✓
  • b.161.9 kips
  • c.194.2 kips
  • d.259.0 kips

ASCE 7-16 Sections 2.3.6 and 12.4.2: 0.9D - Ev + Eh, i.e. (0.9 - 0.2 SDS)D with rho QE acting upward. (0.9 - 0.2 x 1)(75) - 1.3(140) = 52.5 - 182.0 = -129.5 kips, so net uplift (tension) of 129.5 kips. Using 0.9D without the vertical seismic term, or the 1.2D combination, overstates the dead load available to resist overturning.

Seismic Analysis Procedures

A collector in a Seismic Design Category D building has an axial force QE = 40 kips from the design seismic forces. The seismic force-resisting system has an overstrength factor of 2.5. What seismic axial force must the collector be designed for under the overstrength load combinations?

  • a.40 kips
  • b.100 kips✓
  • c.125 kips
  • d.130 kips

ASCE 7-16 Section 12.10.2.1 requires collectors in SDC C through F to be designed for seismic load effects including overstrength: Emh = Omega_0 x QE = 2.5 x 40 = 100 kips (Section 12.4.3). Redundancy rho is taken as 1.0 with overstrength combinations, so stacking 1.3 on top is wrong, and designing for QE alone lets the collector become the weak link before the walls or frames yield.

Seismic Analysis Procedures

A collector in a Seismic Design Category D building has an axial force QE = 65 kips from the design seismic forces. The seismic force-resisting system has an overstrength factor of 3. What seismic axial force must the collector be designed for under the overstrength load combinations?

  • a.65 kips
  • b.195 kips✓
  • c.244 kips
  • d.254 kips

ASCE 7-16 Section 12.10.2.1 requires collectors in SDC C through F to be designed for seismic load effects including overstrength: Emh = Omega_0 x QE = 3 x 65 = 195 kips (Section 12.4.3). Redundancy rho is taken as 1.0 with overstrength combinations, so stacking 1.3 on top is wrong, and designing for QE alone lets the collector become the weak link before the walls or frames yield.

Seismic Analysis Procedures

A collector in a Seismic Design Category D building has an axial force QE = 28 kips from the design seismic forces. The seismic force-resisting system has an overstrength factor of 2. What seismic axial force must the collector be designed for under the overstrength load combinations?

  • a.28 kips
  • b.56 kips✓
  • c.70 kips
  • d.73 kips

ASCE 7-16 Section 12.10.2.1 requires collectors in SDC C through F to be designed for seismic load effects including overstrength: Emh = Omega_0 x QE = 2 x 28 = 56 kips (Section 12.4.3). Redundancy rho is taken as 1.0 with overstrength combinations, so stacking 1.3 on top is wrong, and designing for QE alone lets the collector become the weak link before the walls or frames yield.

Seismic Analysis Procedures

A flexible wood roof diaphragm spans L = 120 ft between end shear walls and is 60 ft deep. The uniform seismic load on the diaphragm is 400 lb/ft. What is the maximum unit shear in the diaphragm at the end walls?

  • a.200 lb/ft
  • b.268 lb/ft
  • c.320 lb/ft
  • d.400 lb/ft✓

The diaphragm acts as a simple beam: end reaction V = wL/2 = 400 x 120/2 = 24,000 lb. Unit shear v = V/b = 24,000/60 = 400 lb/ft. Using the full load wL in place of the reaction doubles the answer, and dividing by the span instead of the depth mixes up the two plan dimensions.

Seismic Analysis Procedures

A flexible wood roof diaphragm spans L = 80 ft between end shear walls and is 40 ft deep. The uniform seismic load on the diaphragm is 650 lb/ft. What is the maximum unit shear in the diaphragm at the end walls?

  • a.325 lb/ft
  • b.650 lb/ft✓
  • c.812 lb/ft
  • d.1,300 lb/ft

The diaphragm acts as a simple beam: end reaction V = wL/2 = 650 x 80/2 = 26,000 lb. Unit shear v = V/b = 26,000/40 = 650 lb/ft. Using the full load wL in place of the reaction doubles the answer, and dividing by the span instead of the depth mixes up the two plan dimensions.

Seismic Analysis Procedures

A flexible wood roof diaphragm spans L = 200 ft between end shear walls and is 100 ft deep. The uniform seismic load on the diaphragm is 300 lb/ft. What is the maximum unit shear in the diaphragm at the end walls?

  • a.150 lb/ft
  • b.300 lb/ft✓
  • c.375 lb/ft
  • d.600 lb/ft

The diaphragm acts as a simple beam: end reaction V = wL/2 = 300 x 200/2 = 30,000 lb. Unit shear v = V/b = 30,000/100 = 300 lb/ft. Using the full load wL in place of the reaction doubles the answer, and dividing by the span instead of the depth mixes up the two plan dimensions.

Seismic Analysis Procedures

A flexible wood roof diaphragm spans L = 96 ft between end shear walls and is 48 ft deep. The uniform seismic load on the diaphragm is 500 lb/ft. What is the maximum unit shear in the diaphragm at the end walls?

  • a.250 lb/ft
  • b.400 lb/ft
  • c.500 lb/ft✓
  • d.1,000 lb/ft

The diaphragm acts as a simple beam: end reaction V = wL/2 = 500 x 96/2 = 24,000 lb. Unit shear v = V/b = 24,000/48 = 500 lb/ft. Using the full load wL in place of the reaction doubles the answer, and dividing by the span instead of the depth mixes up the two plan dimensions.

Seismic Analysis Procedures

A flexible diaphragm spans 120 ft between shear walls, is 60 ft deep, and carries a uniform seismic load of 400 lb/ft. What is the maximum chord force?

  • a.6,000 lb
  • b.12,000 lb✓
  • c.24,000 lb
  • d.48,000 lb

The chords resist the diaphragm bending moment as a tension-compression couple: M = wL^2/8 = 400 x 120^2/8 = 720,000 lb-ft; T = C = M/b = 720,000/60 = 12,000 lb at midspan. The value 24,000 lb is the end reaction (a shear, not a chord force), and dividing the moment by the span rather than the depth uses the wrong lever arm.

Seismic Analysis Procedures

A flexible diaphragm spans 100 ft between shear walls, is 40 ft deep, and carries a uniform seismic load of 550 lb/ft. What is the maximum chord force?

  • a.6,875 lb
  • b.8,594 lb
  • c.11,458 lb
  • d.17,188 lb✓

The chords resist the diaphragm bending moment as a tension-compression couple: M = wL^2/8 = 550 x 100^2/8 = 687,500 lb-ft; T = C = M/b = 687,500/40 = 17,188 lb at midspan. The value 27,500 lb is the end reaction (a shear, not a chord force), and dividing the moment by the span rather than the depth uses the wrong lever arm.

Seismic Analysis Procedures

A flexible diaphragm spans 150 ft between shear walls, is 75 ft deep, and carries a uniform seismic load of 800 lb/ft. What is the maximum chord force?

  • a.15,000 lb
  • b.20,000 lb
  • c.30,000 lb✓
  • d.60,000 lb

The chords resist the diaphragm bending moment as a tension-compression couple: M = wL^2/8 = 800 x 150^2/8 = 2,250,000 lb-ft; T = C = M/b = 2,250,000/75 = 30,000 lb at midspan. The value 60,000 lb is the end reaction (a shear, not a chord force), and dividing the moment by the span rather than the depth uses the wrong lever arm.

Seismic Analysis Procedures

A flexible diaphragm spans 64 ft between shear walls, is 32 ft deep, and carries a uniform seismic load of 350 lb/ft. What is the maximum chord force?

  • a.2,800 lb
  • b.5,600 lb✓
  • c.11,200 lb
  • d.22,400 lb

The chords resist the diaphragm bending moment as a tension-compression couple: M = wL^2/8 = 350 x 64^2/8 = 179,200 lb-ft; T = C = M/b = 179,200/32 = 5,600 lb at midspan. The value 11,200 lb is the end reaction (a shear, not a chord force), and dividing the moment by the span rather than the depth uses the wrong lever arm.

Seismic Analysis Procedures

A roof diaphragm delivers 24,000 lb to a wall line that is 60 ft long. The only shear wall on that line is 20 ft long and sits at one end; a collector (drag strut) runs along the remaining length. What is the maximum collector force?

  • a.16,000 lb✓
  • b.20,000 lb
  • c.24,000 lb
  • d.32,000 lb

Diaphragm unit shear along the line: 24,000/60 = 400 lb/ft. The collector accumulates this over the length without wall, peaking where it meets the wall: 400 x (60 - 20) = 16,000 lb. Check from the wall side: net shear in the wall (1200 - 400 = 800 lb/ft) x 20 ft gives the same force. The full line load 24,000 lb would apply only if the wall had no length directly loaded by the diaphragm.

Seismic Analysis Procedures

A roof diaphragm delivers 18,000 lb to a wall line that is 40 ft long. The only shear wall on that line is 16 ft long and sits at one end; a collector (drag strut) runs along the remaining length. What is the maximum collector force?

  • a.10,800 lb✓
  • b.13,500 lb
  • c.16,200 lb
  • d.18,000 lb

Diaphragm unit shear along the line: 18,000/40 = 450 lb/ft. The collector accumulates this over the length without wall, peaking where it meets the wall: 450 x (40 - 16) = 10,800 lb. Check from the wall side: net shear in the wall (1125 - 450 = 675 lb/ft) x 16 ft gives the same force. The full line load 18,000 lb would apply only if the wall had no length directly loaded by the diaphragm.

Seismic Analysis Procedures

A roof diaphragm delivers 30,000 lb to a wall line that is 100 ft long. The only shear wall on that line is 40 ft long and sits at one end; a collector (drag strut) runs along the remaining length. What is the maximum collector force?

  • a.12,000 lb
  • b.15,000 lb
  • c.18,000 lb✓
  • d.30,000 lb

Diaphragm unit shear along the line: 30,000/100 = 300 lb/ft. The collector accumulates this over the length without wall, peaking where it meets the wall: 300 x (100 - 40) = 18,000 lb. Check from the wall side: net shear in the wall (750 - 300 = 450 lb/ft) x 40 ft gives the same force. The full line load 30,000 lb would apply only if the wall had no length directly loaded by the diaphragm.

Seismic Analysis Procedures

A roof diaphragm delivers 12,000 lb to a wall line that is 48 ft long. The only shear wall on that line is 12 ft long and sits at one end; a collector (drag strut) runs along the remaining length. What is the maximum collector force?

  • a.9,000 lb✓
  • b.11,250 lb
  • c.12,000 lb
  • d.13,500 lb

Diaphragm unit shear along the line: 12,000/48 = 250 lb/ft. The collector accumulates this over the length without wall, peaking where it meets the wall: 250 x (48 - 12) = 9,000 lb. Check from the wall side: net shear in the wall (1000 - 250 = 750 lb/ft) x 12 ft gives the same force. The full line load 12,000 lb would apply only if the wall had no length directly loaded by the diaphragm.

Seismic Analysis Procedures

A rigid diaphragm with no torsion delivers a story shear of 100 kips to 3 parallel shear walls with relative rigidities A = 2, B = 3, C = 5. What shear does wall C resist?

  • a.30.0 kips
  • b.33.3 kips
  • c.40.0 kips
  • d.50.0 kips✓

With a rigid diaphragm, walls displace equally and share force in proportion to rigidity: V_C = V x R/sum(R) = 100 x 5/10 = 50.0 kips. An equal split (33.3 kips each) or a tributary-width split would be the logic for a flexible diaphragm, not a rigid one.

Seismic Analysis Procedures

A rigid diaphragm with no torsion delivers a story shear of 240 kips to 3 parallel shear walls with relative rigidities A = 1, B = 1, C = 4. What shear does wall A resist?

  • a.30.0 kips
  • b.40.0 kips✓
  • c.80.0 kips
  • d.200.0 kips

With a rigid diaphragm, walls displace equally and share force in proportion to rigidity: V_A = V x R/sum(R) = 240 x 1/6 = 40.0 kips. An equal split (80.0 kips each) or a tributary-width split would be the logic for a flexible diaphragm, not a rigid one.

Seismic Analysis Procedures

A rigid diaphragm with no torsion delivers a story shear of 180 kips to 2 parallel shear walls with relative rigidities A = 3, B = 6. What shear does wall A resist?

  • a.60.0 kips✓
  • b.78.0 kips
  • c.90.0 kips
  • d.120.0 kips

With a rigid diaphragm, walls displace equally and share force in proportion to rigidity: V_A = V x R/sum(R) = 180 x 3/9 = 60.0 kips. An equal split (90.0 kips each) or a tributary-width split would be the logic for a flexible diaphragm, not a rigid one.

Seismic Analysis Procedures

A rigid diaphragm with no torsion delivers a story shear of 150 kips to 3 parallel shear walls with relative rigidities A = 4, B = 2.5, C = 3.5. What shear does wall B resist?

  • a.22.5 kips
  • b.25.1 kips
  • c.30.0 kips
  • d.37.5 kips✓

With a rigid diaphragm, walls displace equally and share force in proportion to rigidity: V_B = V x R/sum(R) = 150 x 2.5/10 = 37.5 kips. An equal split (50.0 kips each) or a tributary-width split would be the logic for a flexible diaphragm, not a rigid one.

Seismic Analysis Procedures

North-south shear walls in a rigid-diaphragm building are located (measured from the west edge) as follows: R = 4 at x = 0 ft; R = 2 at x = 60 ft. Where is the center of rigidity in the x-direction?

  • a.10.0 ft
  • b.15.0 ft
  • c.20.0 ft✓
  • d.30.0 ft

x_cr = sum(R x)/sum(R) = (4 x 0 + 2 x 60)/6 = 20.0 ft from the west edge. The center of rigidity is pulled toward the stiffer walls; the geometric midpoint (30 ft) would be correct only for a symmetric layout, and measuring from the wrong edge gives 40.0 ft.

Seismic Analysis Procedures

North-south shear walls in a rigid-diaphragm building are located (measured from the west edge) as follows: R = 3 at x = 0 ft; R = 3 at x = 40 ft; R = 6 at x = 100 ft. Where is the center of rigidity in the x-direction?

  • a.60.0 ft✓
  • b.75.0 ft
  • c.90.0 ft
  • d.120.0 ft

x_cr = sum(R x)/sum(R) = (3 x 0 + 3 x 40 + 6 x 100)/12 = 60.0 ft from the west edge. The center of rigidity is pulled toward the stiffer walls; the geometric midpoint (50 ft) would be correct only for a symmetric layout, and measuring from the wrong edge gives 40.0 ft.

Seismic Analysis Procedures

North-south shear walls in a rigid-diaphragm building are located (measured from the west edge) as follows: R = 5 at x = 0 ft; R = 1 at x = 80 ft. Where is the center of rigidity in the x-direction?

  • a.6.7 ft
  • b.10.0 ft
  • c.13.3 ft✓
  • d.40.0 ft

x_cr = sum(R x)/sum(R) = (5 x 0 + 1 x 80)/6 = 13.3 ft from the west edge. The center of rigidity is pulled toward the stiffer walls; the geometric midpoint (40 ft) would be correct only for a symmetric layout, and measuring from the wrong edge gives 66.7 ft.

Seismic Analysis Procedures

North-south shear walls in a rigid-diaphragm building are located (measured from the west edge) as follows: R = 2 at x = 0 ft; R = 4 at x = 30 ft; R = 2 at x = 90 ft. Where is the center of rigidity in the x-direction?

  • a.37.5 ft✓
  • b.40.0 ft
  • c.45.0 ft
  • d.52.5 ft

x_cr = sum(R x)/sum(R) = (2 x 0 + 4 x 30 + 2 x 90)/8 = 37.5 ft from the west edge. The center of rigidity is pulled toward the stiffer walls; the geometric midpoint (45 ft) would be correct only for a symmetric layout, and measuring from the wrong edge gives 52.5 ft.

Seismic Analysis Procedures

A story shear of 200 kips acts on a rigid diaphragm. The calculated distance between the center of mass and center of rigidity, perpendicular to the force, is 8 ft, and the building dimension perpendicular to the force is 100 ft. What design torsional moment results when accidental torsion adds to the inherent torsion?

  • a.1,000 kip-ft
  • b.1,300 kip-ft
  • c.1,600 kip-ft
  • d.2,600 kip-ft✓

ASCE 7-16 Sections 12.8.4.1 and 12.8.4.2: inherent torsion Mt = V x e = 200 x 8 = 1,600 kip-ft; accidental torsion Mta = V x 0.05L = 200 x 5 = 1,000 kip-ft. Total = 2,600 kip-ft. The 5% is taken on the dimension perpendicular to the applied force; using 10% or ignoring the accidental part are the usual mistakes.

Seismic Analysis Procedures

A story shear of 150 kips acts on a rigid diaphragm. The calculated distance between the center of mass and center of rigidity, perpendicular to the force, is 0 ft, and the building dimension perpendicular to the force is 80 ft. What design torsional moment results when accidental torsion adds to the inherent torsion?

  • a.300 kip-ft
  • b.600 kip-ft✓
  • c.720 kip-ft
  • d.1,200 kip-ft

ASCE 7-16 Sections 12.8.4.1 and 12.8.4.2: inherent torsion Mt = V x e = 150 x 0 = 0 kip-ft; accidental torsion Mta = V x 0.05L = 150 x 4 = 600 kip-ft. Total = 600 kip-ft. The 5% is taken on the dimension perpendicular to the applied force; using 10% or ignoring the accidental part are the usual mistakes.

Seismic Analysis Procedures

A story shear of 320 kips acts on a rigid diaphragm. The calculated distance between the center of mass and center of rigidity, perpendicular to the force, is 12 ft, and the building dimension perpendicular to the force is 160 ft. What design torsional moment results when accidental torsion adds to the inherent torsion?

  • a.2,560 kip-ft
  • b.3,200 kip-ft
  • c.3,840 kip-ft
  • d.6,400 kip-ft✓

ASCE 7-16 Sections 12.8.4.1 and 12.8.4.2: inherent torsion Mt = V x e = 320 x 12 = 3,840 kip-ft; accidental torsion Mta = V x 0.05L = 320 x 8 = 2,560 kip-ft. Total = 6,400 kip-ft. The 5% is taken on the dimension perpendicular to the applied force; using 10% or ignoring the accidental part are the usual mistakes.

Seismic Analysis Procedures

Two cantilever concrete shear walls of equal thickness and material share load through a rigid diaphragm. Wall A is 10 ft high and 20 ft long; wall B is 10 ft high and 10 ft long. Using deflection proportional to 4(h/d)^3 + 3(h/d), what percentage of the shear goes to wall A?

  • a.22%
  • b.67%
  • c.78%✓
  • d.89%

Relative rigidity R = 1/[4(h/d)^3 + 3(h/d)]. Wall A: h/d = 0.50, R = 0.500. Wall B: h/d = 1.00, R = 0.143. Share to A = 0.500/(0.500 + 0.143) = 78%. A split by length alone (67%) ignores that both flexural and shear deformation depend nonlinearly on the aspect ratio.

Seismic Analysis Procedures

Two cantilever concrete shear walls of equal thickness and material share load through a rigid diaphragm. Wall A is 12 ft high and 24 ft long; wall B is 12 ft high and 8 ft long. Using deflection proportional to 4(h/d)^3 + 3(h/d), what percentage of the shear goes to wall A?

  • a.10%
  • b.75%
  • c.90%✓
  • d.96%

Relative rigidity R = 1/[4(h/d)^3 + 3(h/d)]. Wall A: h/d = 0.50, R = 0.500. Wall B: h/d = 1.50, R = 0.056. Share to A = 0.500/(0.500 + 0.056) = 90%. A split by length alone (75%) ignores that both flexural and shear deformation depend nonlinearly on the aspect ratio.

Seismic Analysis Procedures

Two cantilever concrete shear walls of equal thickness and material share load through a rigid diaphragm. Wall A is 14 ft high and 14 ft long; wall B is 14 ft high and 28 ft long. Using deflection proportional to 4(h/d)^3 + 3(h/d), what percentage of the shear goes to wall A?

  • a.11%
  • b.22%✓
  • c.33%
  • d.78%

Relative rigidity R = 1/[4(h/d)^3 + 3(h/d)]. Wall A: h/d = 1.00, R = 0.143. Wall B: h/d = 0.50, R = 0.500. Share to A = 0.143/(0.143 + 0.500) = 22%. A split by length alone (33%) ignores that both flexural and shear deformation depend nonlinearly on the aspect ratio.

Seismic Analysis Procedures

Two cantilever concrete shear walls of equal thickness and material share load through a rigid diaphragm. Wall A is 10 ft high and 30 ft long; wall B is 10 ft high and 15 ft long. Using deflection proportional to 4(h/d)^3 + 3(h/d), what percentage of the shear goes to wall A?

  • a.74%✓
  • b.89%
  • c.92%
  • d.110%

Relative rigidity R = 1/[4(h/d)^3 + 3(h/d)]. Wall A: h/d = 0.33, R = 0.871. Wall B: h/d = 0.67, R = 0.314. Share to A = 0.871/(0.871 + 0.314) = 74%. A split by length alone (67%) ignores that both flexural and shear deformation depend nonlinearly on the aspect ratio.

Seismic Analysis Procedures

A flexible diaphragm is supported by three parallel shear wall lines: two end walls and one interior wall. The spans are 60 ft and 40 ft, and the uniform seismic load is 500 lb/ft. What load goes to the interior wall line?

  • a.10,000 lb
  • b.15,000 lb
  • c.16,667 lb
  • d.25,000 lb✓

A flexible diaphragm distributes load by tributary width, as two simple spans: the interior line receives half of each adjacent span: 500 x (60/2 + 40/2) = 25,000 lb. An equal three-way split or a continuous-beam (5/8) reaction assumes diaphragm stiffness that a flexible diaphragm does not have.

Seismic Analysis Procedures

A flexible diaphragm is supported by three parallel shear wall lines: two end walls and one interior wall. The spans are 80 ft and 80 ft, and the uniform seismic load is 360 lb/ft. What load goes to the interior wall line?

  • a.14,400 lb
  • b.19,200 lb
  • c.28,800 lb✓
  • d.36,000 lb

A flexible diaphragm distributes load by tributary width, as two simple spans: the interior line receives half of each adjacent span: 360 x (80/2 + 80/2) = 28,800 lb. An equal three-way split (19,200 lb) or a continuous-beam interior reaction of 1.25wL = 36,000 lb (5/8 wL from each span) assumes diaphragm stiffness that a flexible diaphragm does not have.

Seismic Analysis Procedures

A flexible diaphragm is supported by three parallel shear wall lines: two end walls and one interior wall. The spans are 50 ft and 100 ft, and the uniform seismic load is 420 lb/ft. What load goes to the interior wall line?

  • a.31,500 lb✓
  • b.39,375 lb
  • c.47,250 lb
  • d.63,000 lb

A flexible diaphragm distributes load by tributary width, as two simple spans: the interior line receives half of each adjacent span: 420 x (50/2 + 100/2) = 31,500 lb. An equal three-way split or a continuous-beam (5/8) reaction assumes diaphragm stiffness that a flexible diaphragm does not have.

Seismic Analysis Procedures

A flexible diaphragm is supported by three parallel shear wall lines: two end walls and one interior wall. The spans are 30 ft and 70 ft, and the uniform seismic load is 600 lb/ft. What load goes to the interior wall line?

  • a.20,000 lb
  • b.21,000 lb
  • c.30,000 lb✓
  • d.37,500 lb

A flexible diaphragm distributes load by tributary width, as two simple spans: the interior line receives half of each adjacent span: 600 x (30/2 + 70/2) = 30,000 lb. An equal three-way split or a continuous-beam (5/8) reaction assumes diaphragm stiffness that a flexible diaphragm does not have.

Seismic Analysis Procedures

A tilt-up wall panel requires a design anchorage force of 1,200 lb per foot of wall. Wall anchors connect to roof framing members spaced 8 ft on center. What force must each anchor (and the tie it connects to) be designed for?

  • a.9,600 lb✓
  • b.12,000 lb
  • c.14,400 lb
  • d.19,200 lb

Each anchor collects the wall force over its tributary width: 1,200 lb/ft x 8 ft = 9,600 lb. That force must then be carried by continuous ties or struts into the diaphragm (ASCE 7-16 Section 12.11.2.2.1), typically through a subdiaphragm. Halving the tributary width or using the per-foot value understates the connection demand.

Seismic Analysis Procedures

A tilt-up wall panel requires a design anchorage force of 1,500 lb per foot of wall. Wall anchors connect to roof framing members spaced 4 ft on center. What force must each anchor (and the tie it connects to) be designed for?

  • a.1,500 lb
  • b.3,000 lb
  • c.4,800 lb
  • d.6,000 lb✓

Each anchor collects the wall force over its tributary width: 1,500 lb/ft x 4 ft = 6,000 lb. That force must then be carried by continuous ties or struts into the diaphragm (ASCE 7-16 Section 12.11.2.2.1), typically through a subdiaphragm. Halving the tributary width or using the per-foot value understates the connection demand.

Seismic Analysis Procedures

A tilt-up wall panel requires a design anchorage force of 980 lb per foot of wall. Wall anchors connect to roof framing members spaced 6 ft on center. What force must each anchor (and the tie it connects to) be designed for?

  • a.980 lb
  • b.5,880 lb✓
  • c.8,820 lb
  • d.11,760 lb

Each anchor collects the wall force over its tributary width: 980 lb/ft x 6 ft = 5,880 lb. That force must then be carried by continuous ties or struts into the diaphragm (ASCE 7-16 Section 12.11.2.2.1), typically through a subdiaphragm. Halving the tributary width or using the per-foot value understates the connection demand.

Seismic Analysis Procedures

A subdiaphragm transfers wall anchorage forces of 1,200 lb/ft into the main diaphragm. The subdiaphragm is 24 ft long (parallel to the wall, between continuous crossties) and 16 ft deep. What is the maximum unit shear in the subdiaphragm?

  • a.600 lb/ft
  • b.900 lb/ft✓
  • c.1,260 lb/ft
  • d.1,800 lb/ft

The subdiaphragm spans 24 ft between crossties as a simple beam loaded by the anchorage force: reaction = 1,200 x 24/2 = 14,400 lb, resisted over the 16-ft depth: v = 14,400/16 = 900 lb/ft. Its length-to-depth ratio of 1.50 is within the 2.5:1 limit of ASCE 7-16 Section 12.11.2.2.1. Using the total load instead of the reaction doubles the shear.

Seismic Analysis Procedures

A subdiaphragm transfers wall anchorage forces of 1,000 lb/ft into the main diaphragm. The subdiaphragm is 40 ft long (parallel to the wall, between continuous crossties) and 20 ft deep. What is the maximum unit shear in the subdiaphragm?

  • a.1,000 lb/ft✓
  • b.1,250 lb/ft
  • c.1,400 lb/ft
  • d.2,000 lb/ft

The subdiaphragm spans 40 ft between crossties as a simple beam loaded by the anchorage force: reaction = 1,000 x 40/2 = 20,000 lb, resisted over the 20-ft depth: v = 20,000/20 = 1,000 lb/ft. Its length-to-depth ratio of 2.00 is within the 2.5:1 limit of ASCE 7-16 Section 12.11.2.2.1. Using the total load instead of the reaction doubles the shear.

Seismic Analysis Procedures

A subdiaphragm transfers wall anchorage forces of 1,400 lb/ft into the main diaphragm. The subdiaphragm is 30 ft long (parallel to the wall, between continuous crossties) and 15 ft deep. What is the maximum unit shear in the subdiaphragm?

  • a.1,400 lb/ft✓
  • b.1,750 lb/ft
  • c.1,960 lb/ft
  • d.2,800 lb/ft

The subdiaphragm spans 30 ft between crossties as a simple beam loaded by the anchorage force: reaction = 1,400 x 30/2 = 21,000 lb, resisted over the 15-ft depth: v = 21,000/15 = 1,400 lb/ft. Its length-to-depth ratio of 2.00 is within the 2.5:1 limit of ASCE 7-16 Section 12.11.2.2.1. Using the total load instead of the reaction doubles the shear.

Seismic Analysis Procedures

A torsional moment of 2,000 kip-ft acts on a rigid diaphragm. A wall with relative rigidity R = 4 lies 30 ft from the center of rigidity, and the polar term sum(R d^2) for all walls is 9,000. What torsional shear does this wall receive?

  • a.6.7 kips
  • b.26.7 kips✓
  • c.66.7 kips
  • d.80.0 kips

Torsional shear V_t = T x R x d / sum(R d^2) = 2,000 x 4 x 30 / 9,000 = 26.7 kips. This adds to (or, where it would subtract, is not used to reduce) the wall's direct shear. Dividing the moment by the wall's distance alone (66.7 kips) assumes that single wall resists all of the torsion.

Seismic Analysis Procedures

A torsional moment of 3,600 kip-ft acts on a rigid diaphragm. A wall with relative rigidity R = 2 lies 50 ft from the center of rigidity, and the polar term sum(R d^2) for all walls is 14,000. What torsional shear does this wall receive?

  • a.12.9 kips
  • b.25.7 kips✓
  • c.72.0 kips
  • d.128.6 kips

Torsional shear V_t = T x R x d / sum(R d^2) = 3,600 x 2 x 50 / 14,000 = 25.7 kips. This adds to (or, where it would subtract, is not used to reduce) the wall's direct shear. Dividing the moment by the wall's distance alone (72.0 kips) assumes that single wall resists all of the torsion.