A site has a mapped risk-targeted short-period spectral acceleration Ss = 1.50g and a short-period site coefficient Fa = 1. What is the design spectral response acceleration SDS?

  • a.0.750g
  • b.1.000g✓
  • c.1.500g
  • d.2.250g

ASCE 7-16 Section 11.4.4 adjusts the mapped value for site class: SMS = Fa x Ss = 1 x 1.50 = 1.500g. Section 11.4.5 then takes two-thirds of it: SDS = (2/3)(1.500) = 1.000g. Stopping at 1.500g reports the MCER value SMS, not the design value, and multiplying by 1.5 inverts the two-thirds factor.

Seismic Data and Design Criteria

A site has a mapped risk-targeted short-period spectral acceleration Ss = 1.25g and a short-period site coefficient Fa = 1.2. What is the design spectral response acceleration SDS?

  • a.0.667g
  • b.0.833g
  • c.1.000g✓
  • d.1.500g

ASCE 7-16 Section 11.4.4 adjusts the mapped value for site class: SMS = Fa x Ss = 1.2 x 1.25 = 1.500g. Section 11.4.5 then takes two-thirds of it: SDS = (2/3)(1.500) = 1.000g. Stopping at 1.500g reports the MCER value SMS, not the design value, and multiplying by 1.5 inverts the two-thirds factor.

Seismic Data and Design Criteria

A site has a mapped risk-targeted short-period spectral acceleration Ss = 0.90g and a short-period site coefficient Fa = 1.14. What is the design spectral response acceleration SDS?

  • a.0.274g
  • b.0.480g
  • c.0.600g
  • d.0.684g✓

ASCE 7-16 Section 11.4.4 adjusts the mapped value for site class: SMS = Fa x Ss = 1.14 x 0.90 = 1.026g. Section 11.4.5 then takes two-thirds of it: SDS = (2/3)(1.026) = 0.684g. Stopping at 1.026g reports the MCER value SMS, not the design value, and multiplying by 1.5 inverts the two-thirds factor.

Seismic Data and Design Criteria

A site has a mapped risk-targeted short-period spectral acceleration Ss = 2.00g and a short-period site coefficient Fa = 1.2. What is the design spectral response acceleration SDS?

  • a.1.333g
  • b.1.600g✓
  • c.2.400g
  • d.3.600g

ASCE 7-16 Section 11.4.4 adjusts the mapped value for site class: SMS = Fa x Ss = 1.2 x 2.00 = 2.400g. Section 11.4.5 then takes two-thirds of it: SDS = (2/3)(2.400) = 1.600g. Stopping at 2.400g reports the MCER value SMS, not the design value, and multiplying by 1.5 inverts the two-thirds factor.

Seismic Data and Design Criteria

For a site with mapped 1-second spectral acceleration S1 = 0.60g and long-period site coefficient Fv = 1.7, what is the design 1-second spectral acceleration SD1?

  • a.0.353g
  • b.0.400g
  • c.0.680g✓
  • d.1.020g

SM1 = Fv x S1 = 1.7 x 0.60 = 1.020g (ASCE 7-16 Sec. 11.4.4), and SD1 = (2/3)SM1 = 0.680g (Sec. 11.4.5). 1.020g is the MCER-level value before the two-thirds reduction, and 0.400g ignores the site coefficient altogether.

Seismic Data and Design Criteria

For a site with mapped 1-second spectral acceleration S1 = 0.45g and long-period site coefficient Fv = 1.85, what is the design 1-second spectral acceleration SD1?

  • a.0.243g
  • b.0.300g
  • c.0.555g✓
  • d.0.833g

SM1 = Fv x S1 = 1.85 x 0.45 = 0.833g (ASCE 7-16 Sec. 11.4.4), and SD1 = (2/3)SM1 = 0.555g (Sec. 11.4.5). 0.833g is the MCER-level value before the two-thirds reduction, and 0.300g ignores the site coefficient altogether.

Seismic Data and Design Criteria

For a site with mapped 1-second spectral acceleration S1 = 0.75g and long-period site coefficient Fv = 1.7, what is the design 1-second spectral acceleration SD1?

  • a.0.850g✓
  • b.1.062g
  • c.1.275g
  • d.1.912g

SM1 = Fv x S1 = 1.7 x 0.75 = 1.275g (ASCE 7-16 Sec. 11.4.4), and SD1 = (2/3)SM1 = 0.850g (Sec. 11.4.5). 1.275g is the MCER-level value before the two-thirds reduction, and 0.500g ignores the site coefficient altogether.

Seismic Data and Design Criteria

A design response spectrum is built with SDS = 1.00g and SD1 = 0.60g. At what period Ts does the constant-acceleration plateau end and the 1/T descending branch begin?

  • a.0.60 s✓
  • b.0.75 s
  • c.1.20 s
  • d.1.67 s

ASCE 7-16 Section 11.4.6 defines Ts = SD1/SDS = 0.60/1.00 = 0.60 s. The value 0.12 s is T0 = 0.2Ts, where the plateau starts rather than ends, and 1.67 s inverts the ratio.

Seismic Data and Design Criteria

A design response spectrum is built with SDS = 1.20g and SD1 = 0.54g. At what period Ts does the constant-acceleration plateau end and the 1/T descending branch begin?

  • a.0.09 s
  • b.0.30 s
  • c.0.36 s
  • d.0.45 s✓

ASCE 7-16 Section 11.4.6 defines Ts = SD1/SDS = 0.54/1.20 = 0.45 s. The value 0.09 s is T0 = 0.2Ts, where the plateau starts rather than ends, and 2.22 s inverts the ratio.

Seismic Data and Design Criteria

A design response spectrum is built with SDS = 0.80g and SD1 = 0.50g. At what period Ts does the constant-acceleration plateau end and the 1/T descending branch begin?

  • a.0.12 s
  • b.0.62 s✓
  • c.1.25 s
  • d.1.60 s

ASCE 7-16 Section 11.4.6 defines Ts = SD1/SDS = 0.50/0.80 = 0.62 s. The value 0.12 s is T0 = 0.2Ts, where the plateau starts rather than ends, and 1.60 s inverts the ratio.

Seismic Data and Design Criteria

Soil properties at a building site are not known in enough detail to classify the site. Which site class does ASCE 7-16 direct the engineer to assume unless the building official or geotechnical data indicate softer soil?

  • a.Site Class D✓
  • b.Site Class C
  • c.Site Class B
  • d.Site Class E

ASCE 7-16 Section 11.4.3 makes Site Class D (stiff soil) the default when soil properties are not known in sufficient detail. Site Class B (rock) would be unconservative because rock sites take no amplification, and Site Class E is assumed only when the building official or geotechnical data point to soft clay.

Seismic Data and Design Criteria

Site class is assigned from average soil properties measured over what depth below the site surface?

  • a.The upper 30 ft of the site profile
  • b.The full depth down to bedrock
  • c.The depth of the foundation only
  • d.The upper 100 ft of the site profile✓

ASCE 7-16 Chapter 20 classifies the site from shear wave velocity, penetration resistance or undrained shear strength averaged over the top 100 ft (30 m). Thirty feet confuses 30 m with 30 ft, and the foundation depth alone ignores the deeper soil column that filters and amplifies the motion.

Seismic Data and Design Criteria

Which soil condition generally places a site in Site Class F, calling for a site response analysis rather than tabulated site coefficients?

  • a.Soils vulnerable to failure, such as liquefiable soils✓
  • b.Competent rock with little weathering
  • c.Very dense soil and soft rock with high shear wave velocity
  • d.Stiff soil with moderate blow counts

ASCE 7-16 Section 20.3.1 assigns Site Class F to soils vulnerable to potential failure or collapse under seismic loading (liquefiable soils, quick clays, peats, very thick soft clays), and Section 11.4.8 then requires a site response analysis. Very dense soil is Site Class C and stiff soil is Site Class D, both handled with site coefficients.

Seismic Data and Design Criteria

Under the California Building Code risk category table, which building is assigned to Risk Category IV?

  • a.A three-story office building
  • b.A retail store with 200 occupants
  • c.A barn used only for the storage of harvested field crops
  • d.A fire station that houses emergency vehicles✓

CBC Table 1604.5 places essential facilities such as fire, rescue and police stations and hospitals with emergency treatment in Risk Category IV. An ordinary office or small retail building is Risk Category II, and an agricultural storage building is Risk Category I.

Seismic Data and Design Criteria

What seismic importance factor Ie applies to a Risk Category III building?

  • a.1.00
  • b.1.15
  • c.1.50
  • d.1.25✓

ASCE 7-16 Table 1.5-2 assigns Ie = 1.25 to Risk Category III. Risk Categories I and II use 1.00 and Risk Category IV uses 1.50; 1.15 is a wind/snow-type factor that does not appear in the seismic column.

Seismic Data and Design Criteria

A Risk Category II building has SDS = 0.62g and SD1 = 0.18g, and S1 is less than 0.75g. SDS of 0.50g or more corresponds to SDC D, while SD1 between 0.133g and 0.20g corresponds to SDC C. Which Seismic Design Category applies?

  • a.SDC B, by averaging the two results
  • b.SDC C, because SD1 always governs
  • c.SDC C, the less severe of the two
  • d.SDC D, the more severe of the two✓

ASCE 7-16 Section 11.6 assigns the more severe category from the short-period and 1-second tables, so SDC D governs. Taking the less severe result or averaging has no basis; the limited exception that lets SDS alone govern applies only to short-period buildings meeting specific conditions.

Seismic Data and Design Criteria

A Risk Category IV hospital is located where the mapped S1 is 0.80g. Which Seismic Design Category is assigned?

  • a.SDC F✓
  • b.SDC E
  • c.SDC C
  • d.SDC D

ASCE 7-16 Section 11.6: where S1 is 0.75g or greater, Risk Category I, II and III structures are SDC E and Risk Category IV structures are SDC F. SDC D is the highest category that the SDS/SD1 tables alone can produce, so it understates this near-fault site.

Seismic Data and Design Criteria

The risk-targeted maximum considered earthquake (MCER) ground motions in ASCE 7-16 are defined to produce what target?

  • a.A 5% probability of collapse in 10 years
  • b.A 10% probability of collapse in 50 years
  • c.A 2% probability of damage in 100 years
  • d.A 1% probability of collapse in 50 years✓

ASCE 7-16 Chapter 21 and the Section 11.2 definition describe MCER motions as risk-targeted: a 1% probability of collapse within a 50-year period for an ordinary building. The 10%-in-50-year figure is the older design-basis hazard level for ground motion exceedance, not a collapse risk.

Seismic Data and Design Criteria

Which combination of conditions makes soil most susceptible to liquefaction during strong shaking?

  • a.Dense, dry, well-graded gravel far above the water table
  • b.Stiff, overconsolidated clay at depth
  • c.Loose, saturated, clean sand near the surface✓
  • d.Weathered rock with a thin soil cover

Liquefaction occurs when cyclic shaking raises pore water pressure in loose, saturated, cohesionless soil until effective stress and shear strength are lost. Dense or dry granular soils do not build up that pore pressure, and stiff clays do not liquefy in the classic sense.

Seismic Data and Design Criteria

A site-specific geotechnical report evaluates liquefaction potential for a Seismic Design Category D building. Which ground motion parameter does ASCE 7-16 direct be used for that evaluation?

  • a.The seismic response coefficient Cs
  • b.Peak ground acceleration adjusted for site effects✓
  • c.The mapped long-period transition TL
  • d.The design 1-second spectral acceleration SD1 without adjustment

ASCE 7-16 Section 11.8.3 requires liquefaction evaluation for the MCEG peak ground acceleration adjusted for site class (PGAM = FPGA x PGA) or a site-specific value. Cs is a building base shear coefficient that includes R, and TL is a period, not an acceleration.

Seismic Data and Design Criteria

For periods longer than the long-period transition period TL, how does the design spectral acceleration vary with period T?

  • a.It rises in proportion to T
  • b.It remains constant at SD1
  • c.In proportion to 1/T
  • d.In proportion to 1/T squared✓

ASCE 7-16 Section 11.4.6: beyond TL the spectrum follows Sa = SD1 x TL / T^2, the constant-displacement branch. The 1/T form applies between Ts and TL (constant velocity), and the spectrum is flat only on the short-period plateau at SDS.

Seismic Data and Design Criteria

Compared with a rock site, how does a soft soil site generally change the ground motion that a long-period building experiences?

  • a.It amplifies long-period motion, raising Fv✓
  • b.It has no effect once S1 is determined
  • c.It filters out long-period motion entirely
  • d.It lowers Fv below the value used for rock

Soft soil deposits amplify long-period shaking, which is why the long-period site coefficient Fv in ASCE 7-16 Section 11.4.4 increases from rock toward soft soil. Mexico City (1985) and the San Francisco Marina and Oakland (1989) are the classic examples; the mapped S1 is a rock-site value that must still be adjusted.

Seismic Data and Design Criteria

When the default Site Class D is assumed because soil data are lacking, what additional restriction does ASCE 7-16 place on the short-period site coefficient?

  • a.Fa may not be taken as more than 1.2
  • b.Fa must be taken as exactly 1.0
  • c.Fa is replaced by the coefficient Fv
  • d.Fa may not be taken as less than 1.2✓

ASCE 7-16 Section 11.4.4 sets a floor of Fa = 1.2 when Site Class D is selected as the default, because an unverified site could behave like Site Class C, where short-period amplification can be higher. A value of 1.0 would apply to measured Site Class D at high Ss, not to a default assumption.

Seismic Data and Design Criteria

For periods shorter than T0, how is the design response spectrum defined?

  • a.It ramps linearly from 0.4SDS at T = 0 up to SDS at T0✓
  • b.It falls from SDS at T = 0 down to 0.4SDS at T0
  • c.It stays constant at SDS from T = 0 up to T0
  • d.It ramps linearly from zero at T = 0 up to SDS at T0

ASCE 7-16 Section 11.4.6: for T less than T0, Sa = SDS(0.4 + 0.6T/T0), a linear ramp starting at 0.4SDS (the effective peak ground acceleration) and reaching the plateau at T0 = 0.2Ts. It does not start at zero, because a perfectly rigid object still feels the ground acceleration.

Seismic Characteristics of Engineered Systems

Elastic analysis under the design seismic forces gives a story drift of 0.45 in. for a story 13 ft high. The system has Cd = 5.5 and the building has Ie = 1. What is the design story drift to compare with the allowable drift?

  • a.2.48 in.✓
  • b.3.09 in.
  • c.3.71 in.
  • d.4.95 in.

ASCE 7-16 Eq. 12.8-15 amplifies the elastic displacement: delta = Cd x delta_xe / Ie = 5.5 x 0.45 / 1 = 2.48 in. Reporting 0.45 in. ignores inelastic amplification; multiplying by Ie instead of dividing double-counts importance, which is already in the forces that produced delta_xe.

Seismic Characteristics of Engineered Systems

Elastic analysis under the design seismic forces gives a story drift of 0.30 in. for a story 12 ft high. The system has Cd = 5 and the building has Ie = 1.25. What is the design story drift to compare with the allowable drift?

  • a.0.30 in.
  • b.0.60 in.
  • c.1.20 in.✓
  • d.1.88 in.

ASCE 7-16 Eq. 12.8-15 amplifies the elastic displacement: delta = Cd x delta_xe / Ie = 5 x 0.30 / 1.25 = 1.20 in. Reporting 0.30 in. ignores inelastic amplification; multiplying by Ie instead of dividing double-counts importance, which is already in the forces that produced delta_xe.

Seismic Characteristics of Engineered Systems

Elastic analysis under the design seismic forces gives a story drift of 0.52 in. for a story 10 ft high. The system has Cd = 4 and the building has Ie = 1. What is the design story drift to compare with the allowable drift?

  • a.0.52 in.
  • b.2.08 in.✓
  • c.2.60 in.
  • d.3.12 in.

ASCE 7-16 Eq. 12.8-15 amplifies the elastic displacement: delta = Cd x delta_xe / Ie = 4 x 0.52 / 1 = 2.08 in. Reporting 0.52 in. ignores inelastic amplification; multiplying by Ie instead of dividing double-counts importance, which is already in the forces that produced delta_xe.

Seismic Characteristics of Engineered Systems

Elastic analysis under the design seismic forces gives a story drift of 0.20 in. for a story 14 ft high. The system has Cd = 5 and the building has Ie = 1.5. What is the design story drift to compare with the allowable drift?

  • a.0.20 in.
  • b.0.40 in.
  • c.0.47 in.
  • d.0.67 in.✓

ASCE 7-16 Eq. 12.8-15 amplifies the elastic displacement: delta = Cd x delta_xe / Ie = 5 x 0.20 / 1.5 = 0.67 in. Reporting 0.20 in. ignores inelastic amplification; multiplying by Ie instead of dividing double-counts importance, which is already in the forces that produced delta_xe.

Seismic Characteristics of Engineered Systems

At a story, total unfactored vertical load above is Px = 2,400 kips, design story drift is 1.8 in., story shear is Vx = 310 kips, story height is 144 in., Cd = 5.5 and Ie = 1. What is the stability coefficient theta?

  • a.0.009
  • b.0.012
  • c.0.014
  • d.0.018✓

ASCE 7-16 Eq. 12.8-16: theta = Px x Delta x Ie / (Vx x hsx x Cd) = (2,400 x 1.8 x 1) / (310 x 144 x 5.5) = 0.018. Leaving Cd out of the denominator gives 0.097, which overstates theta. P-delta effects need not be considered when theta is 0.10 or less.

Seismic Characteristics of Engineered Systems

At a story, total unfactored vertical load above is Px = 5,200 kips, design story drift is 2.2 in., story shear is Vx = 420 kips, story height is 156 in., Cd = 5 and Ie = 1. What is the stability coefficient theta?

  • a.0.035✓
  • b.0.087
  • c.0.175
  • d.0.218

ASCE 7-16 Eq. 12.8-16: theta = Px x Delta x Ie / (Vx x hsx x Cd) = (5,200 x 2.2 x 1) / (420 x 156 x 5) = 0.035. Leaving Cd out of the denominator gives 0.175, which overstates theta. P-delta effects need not be considered when theta is 0.10 or less.

Seismic Characteristics of Engineered Systems

At a story, total unfactored vertical load above is Px = 3,600 kips, design story drift is 1.5 in., story shear is Vx = 500 kips, story height is 144 in., Cd = 4 and Ie = 1.25. What is the stability coefficient theta?

  • a.0.012
  • b.0.016
  • c.0.019
  • d.0.023✓

ASCE 7-16 Eq. 12.8-16: theta = Px x Delta x Ie / (Vx x hsx x Cd) = (3,600 x 1.5 x 1.25) / (500 x 144 x 4) = 6,750 / 288,000 = 0.023. Leaving Cd out of the denominator gives 6,750 / 72,000 = 0.094, which overstates theta fourfold. P-delta effects need not be considered when theta is 0.10 or less.

Seismic Characteristics of Engineered Systems

For a story with shear demand-to-capacity ratio beta = 1 in a system with Cd = 5.5, what is the maximum permitted stability coefficient theta_max?

  • a.0.061
  • b.0.073
  • c.0.091✓
  • d.0.250

ASCE 7-16 Eq. 12.8-17: theta_max = 0.5/(beta x Cd) = 0.5/(1 x 5.5) = 0.091, and it may not exceed 0.25. The value 0.10 is only the threshold above which P-delta effects must be included, and 0.25 is the absolute cap, which does not govern here.

Seismic Characteristics of Engineered Systems

For a story with shear demand-to-capacity ratio beta = 0.8 in a system with Cd = 4, what is the maximum permitted stability coefficient theta_max?

  • a.0.156✓
  • b.0.195
  • c.0.250
  • d.0.312

ASCE 7-16 Eq. 12.8-17: theta_max = 0.5/(beta x Cd) = 0.5/(0.8 x 4) = 0.156, and it may not exceed 0.25. The value 0.10 is only the threshold above which P-delta effects must be included, and 0.25 is the absolute cap, which does not govern here.

Seismic Characteristics of Engineered Systems

Two adjacent buildings on the same property (both Ie = 1.0) have maximum elastic displacements at the level of the shorter roof of 0.8 in. (Cd = 5.5) and 0.5 in. (Cd = 5). What minimum separation is required between them?

  • a.0.94 in.
  • b.5.06 in.✓
  • c.6.33 in.
  • d.6.90 in.

ASCE 7-16 Section 12.12.3: each inelastic displacement is delta_M = Cd x delta_max / Ie, giving 4.40 in. and 2.50 in. Buildings on the same property are separated by the SRSS: sqrt(4.40^2 + 2.50^2) = 5.06 in. The absolute sum 6.90 in. is more than the code requires, and combining the elastic values (0.94 in.) ignores Cd.

Seismic Characteristics of Engineered Systems

Two adjacent buildings on the same property (both Ie = 1.0) have maximum elastic displacements at the level of the shorter roof of 1.2 in. (Cd = 4) and 0.9 in. (Cd = 4). What minimum separation is required between them?

  • a.6.00 in.✓
  • b.7.50 in.
  • c.8.40 in.
  • d.9.00 in.

ASCE 7-16 Section 12.12.3: each inelastic displacement is delta_M = Cd x delta_max / Ie, giving 4.80 in. and 3.60 in. Buildings on the same property are separated by the SRSS: sqrt(4.80^2 + 3.60^2) = 6.00 in. The absolute sum 8.40 in. is more than the code requires, and combining the elastic values (1.50 in.) ignores Cd.

Seismic Characteristics of Engineered Systems

Two adjacent buildings on the same property (both Ie = 1.0) have maximum elastic displacements at the level of the shorter roof of 0.6 in. (Cd = 5) and 0.6 in. (Cd = 5.5). What minimum separation is required between them?

  • a.4.46 in.✓
  • b.5.57 in.
  • c.6.30 in.
  • d.6.69 in.

ASCE 7-16 Section 12.12.3: each inelastic displacement is delta_M = Cd x delta_max / Ie, giving 3.00 in. and 3.30 in. Buildings on the same property are separated by the SRSS: sqrt(3.00^2 + 3.30^2) = 4.46 in. The absolute sum 6.30 in. is more than the code requires, and combining the elastic values (0.85 in.) ignores Cd.

Seismic Characteristics of Engineered Systems

What does the response modification coefficient R represent in seismic design?

  • a.The reliability penalty applied to systems with few lateral elements
  • b.The ratio of actual system strength to the design-level strength
  • c.The amplification of elastic drift needed to estimate the true inelastic displacement
  • d.The reduction of elastic force demand allowed for ductility and overstrength✓

R (ASCE 7-16 Table 12.2-1) divides the elastic demand because a well-detailed system dissipates energy inelastically and has reserve strength. Amplifying drift is the job of Cd, the strength ratio is the overstrength factor, and the reliability penalty is the redundancy factor rho.

Seismic Characteristics of Engineered Systems

In a building frame system, how are gravity and lateral loads carried?

  • a.Bearing walls carry gravity and also resist all of the lateral load
  • b.Cantilevered columns carry gravity load and also resist all of the lateral load
  • c.A frame carries gravity; shear walls or braced frames resist lateral load✓
  • d.Moment frames resist both gravity load and all of the lateral load

ASCE 7-16 Section 11.2 defines a building frame system as an essentially complete space frame for gravity with shear walls or braced frames for seismic resistance. If the walls carry significant gravity load, it is a bearing wall system with a lower R; a frame resisting both by flexure is a moment-resisting frame system.

Seismic Characteristics of Engineered Systems

In a dual system, the moment frames must be capable of resisting at least what share of the design seismic forces?

  • a.75%
  • b.25%✓
  • c.50%
  • d.10%

ASCE 7-16 Section 12.2.5.1 requires the moment frames of a dual system to resist at least 25% of the design seismic forces as a backup to the walls or braced frames, with total resistance shared in proportion to rigidity. Lower values would not provide a meaningful second line of defense; higher ones are not required.

Seismic Characteristics of Engineered Systems

A story's lateral stiffness is 65% of the stiffness of the story above. Which vertical irregularity exists?

  • a.Weight (mass) irregularity
  • b.Stiffness-soft story irregularity✓
  • c.Vertical geometric irregularity
  • d.In-plane discontinuity irregularity

ASCE 7-16 Table 12.3-2 defines a soft story where lateral stiffness is less than 70% of the story above (or less than 80% of the average of the three stories above). Mass irregularity compares story weights (more than 150%), and vertical geometric irregularity compares horizontal dimensions of the lateral system (more than 130%).

Seismic Characteristics of Engineered Systems

A story's lateral strength is 75% of the strength of the story above. How is this condition classified?

  • a.Soft story irregularity
  • b.Weak story irregularity✓
  • c.Torsional irregularity
  • d.Mass irregularity

ASCE 7-16 Table 12.3-2: a weak story has lateral strength less than 80% of the story above (extreme if less than 65%). A soft story is a stiffness comparison, not a strength comparison; the two often occur together, as in open-front tuck-under parking, but are checked separately.

Seismic Characteristics of Engineered Systems

With accidental torsion included, the maximum story drift at one end of a rigid-diaphragm building is 1.3 times the average of the drifts at the two ends. What does this indicate?

  • a.Torsional irregularity (ratio above 1.2)✓
  • b.Extreme torsional irregularity (above 1.2)
  • c.No irregularity (ratio is below 1.5)
  • d.Reentrant corner irregularity (above 1.15)

ASCE 7-16 Table 12.3-1: torsional irregularity exists when the maximum drift exceeds 1.2 times the average; extreme torsional irregularity begins at 1.4. A ratio of 1.3 is therefore irregular but not extreme. Reentrant corners are a plan-geometry test (both projections more than 15% of the plan dimension).

Seismic Characteristics of Engineered Systems

A floor diaphragm has an opening equal to 55% of its gross enclosed area. Which horizontal irregularity applies?

  • a.Reentrant corner irregularity
  • b.Nonparallel system irregularity
  • c.Diaphragm discontinuity irregularity✓
  • d.Out-of-plane offset discontinuity irregularity

ASCE 7-16 Table 12.3-1 defines diaphragm discontinuity as a cutout or open area greater than 50% of the gross enclosed diaphragm area (or a stiffness change of more than 50% between stories). Out-of-plane offset refers to vertical elements shifting out of their plane, and nonparallel systems to elements not aligned with the major axes.

Seismic Characteristics of Engineered Systems

For a Seismic Design Category D building, what value of the redundancy factor rho applies when the conditions for the lower value are NOT met?

  • a.2.0
  • b.1.3✓
  • c.1.5
  • d.1.0

ASCE 7-16 Section 12.3.4.2 sets rho = 1.3 for SDC D through F unless the structure qualifies for 1.0 (for example, removal of an individual element does not cut story strength by more than 33% or create extreme torsional irregularity). Rho is always 1.0 in SDC B and C.

Seismic Characteristics of Engineered Systems

For which calculation is the redundancy factor rho permitted to be taken as 1.0 even in Seismic Design Category D?

  • a.Braced frame member design
  • b.Drift and P-delta calculations✓
  • c.Shear wall strength design
  • d.Foundation overturning design

ASCE 7-16 Section 12.3.4.1 lists cases where rho is 1.0, including drift and P-delta calculations, nonstructural component design, and members designed with overstrength load combinations. Strength design of the walls, frames and their foundations is exactly where the 1.3 penalty applies.

Seismic Characteristics of Engineered Systems

What is the allowable story drift for a typical Risk Category II steel office building more than four stories tall?

  • a.0.010 times the story height
  • b.0.015 times the story height
  • c.0.020 times the story height✓
  • d.0.025 times the story height

ASCE 7-16 Table 12.12-1 allows 0.020hsx for 'all other structures' in Risk Category I or II. The 0.025hsx limit is reserved for buildings of four stories or fewer with interior finishes designed to accommodate drift; 0.015hsx and 0.010hsx apply to Risk Categories III and IV.

Seismic Characteristics of Engineered Systems

A new building is set back from an interior property line. What minimum setback from the property line does ASCE 7-16 require for seismic separation?

  • a.The SRSS of both buildings' elastic displacements
  • b.The building's own maximum inelastic displacement✓
  • c.Twice the building's computed elastic displacement
  • d.One percent of the structural height of the building

ASCE 7-16 Section 12.12.3: at a property line not common to a public way, the structure is set back at least its own maximum inelastic response displacement delta_M. The SRSS combination is for two buildings on the same property, and it uses inelastic rather than elastic displacements.

Seismic Characteristics of Engineered Systems

What is the purpose of the deflection amplification factor Cd?

  • a.To estimate inelastic displacement from an elastic analysis under reduced forces✓
  • b.To raise design forces for buildings with a higher risk category
  • c.To estimate the peak force that a yielding system can deliver to its connections
  • d.To convert strength-level forces into allowable stress design forces

Design forces are reduced by R, so the elastic analysis displacement understates what the yielding structure will really do; multiplying by Cd (and dividing by Ie) per ASCE 7-16 Section 12.8.6 recovers the expected inelastic displacement. Peak deliverable force is addressed by the overstrength factor, and risk category by Ie.

Seismic Vulnerability and Improvement of Structural Systems

What is the most characteristic earthquake failure of an unreinforced masonry (URM) bearing wall building?

  • a.Ground-story columns hinge because an open tuck-under parking level is far too flexible
  • b.Steel beam flanges fracture at welded connections to the columns
  • c.Walls and parapets fall outward because they are not tied to the floors and roof✓
  • d.Roof collectors buckle because the diaphragm is too stiff and strong

URM walls have little out-of-plane strength and, in older buildings, joists simply bear in wall pockets with no positive anchorage, so walls and parapets peel away and floors lose support. Weld fracture is a steel moment frame problem, and open-front weak stories are typical of wood apartment buildings.

Seismic Vulnerability and Improvement of Structural Systems

Which retrofit measure most directly addresses the main life-safety hazard of an unreinforced masonry building?

  • a.Replacing roofing with a heavier concrete tile system
  • b.Removing interior wood partitions to reduce the building's seismic weight
  • c.Installing wall-to-diaphragm tension anchors and bracing parapets✓
  • d.Adding ornamental masonry veneer to exterior walls

Tension and shear anchors tie the walls to the floor and roof diaphragms, and braced or shortened parapets stop the most common falling hazard. Heavier roofing adds seismic mass, veneer adds another falling hazard, and wood partitions actually contribute some damping and resistance.