California Civil Engineer: Seismic Principles — All Questions
300 questions
In the 1971 San Fernando and 1994 Northridge earthquakes, many tilt-up concrete buildings with wood roofs suffered partial roof collapse. What was the primary cause?
- a.Failure of the wall-to-roof anchorage and lack of continuous crossties✓
- b.Bearing failure of the soil beneath the panel footings
- c.Fracture of the anchor bolts at the steel column bases
- d.Crushing of the concrete wall panels under in-plane shear and overturning forces
Walls pulled away from the roof where ledgers were loaded in cross-grain bending or anchors were too weak, and without continuous ties across the diaphragm the roof framing lost support. These failures produced today's wall anchorage, subdiaphragm and crosstie rules in ASCE 7-16 Section 12.11.2. In-plane panel shear capacity was rarely the problem.
Why are pre-1970s nonductile concrete frame buildings considered a collapse risk?
- a.The frames were designed for wind loads larger than modern seismic loads
- b.Excessive confinement steel makes the columns far too stiff to dissipate seismic energy
- c.Their lightweight floors attract higher forces than modern concrete floors
- d.Widely spaced column ties allow brittle shear failure and loss of gravity support✓
Older concrete columns typically have widely spaced ties with 90-degree hooks and lap splices in hinge zones, so they fail in shear or lose confinement before flexural yielding and can no longer carry gravity load. The problem is too little transverse steel, not too much, as the 1971 Olive View Hospital damage showed.
Which retrofit technique increases the shear strength and confinement of an existing nonductile concrete column?
- a.Cutting the column free from the adjacent masonry infill walls only
- b.Jacketing the column with steel or fiber-reinforced polymer✓
- c.Adding a suspended ceiling around the column capital
- d.Painting the column with an intumescent fire coating
Steel, concrete or FRP jackets add transverse confinement and shear capacity, letting the column deform without brittle failure. Separating a column from partial-height infill can relieve a short-column condition but does not add confinement by itself, and coatings or ceilings have no structural effect.
A multi-story wood apartment building has open parking at the ground level along one side. What seismic deficiency is typical of this configuration?
- a.Excessive redundancy in the ground-story wall lines
- b.An overly stiff ground story that attracts hail damage
- c.A roof diaphragm that is too flexible to span at all
- d.A soft, weak first story prone to sidesway collapse✓
Open-front 'tuck-under' buildings have far less wall at the ground story than above, concentrating drift there; the Northridge Meadows collapse is the well-known example. Retrofits add steel moment frames, cantilever columns or new shear walls at the open line. The deficiency is too little stiffness and strength, not too much.
Welded steel moment frames built before 1994 performed unexpectedly in the Northridge earthquake. What was observed?
- a.Brittle fractures at beam-to-column welded flange connections✓
- b.Shear failure of floor slabs around the column perimeters
- c.Widespread ductile hinging of beams well away from the joints
- d.Global buckling of columns from excessive gravity loading
Inspection after Northridge found brittle fractures starting at the beam bottom flange weld root, with little of the expected ductile hinging. The findings led to the FEMA/SAC studies, tougher weld filler metals and prequalified connections such as the reduced beam section.
An older house has short wood-framed cripple walls between the foundation and the first floor. Which retrofit is standard for this condition?
- a.Replacing the cripple walls with unreinforced brick masonry
- b.Removing the sill plate so that the house can slide freely
- c.Sheathing the cripple walls with plywood and bolting the sill plate✓
- d.Adding a second story to increase the gravity precompression on the walls
Unbraced cripple walls rack and unbolted sills slide off the foundation. Wood structural panel sheathing on the cripple walls plus anchor bolts (or retrofit foundation plates) completes the load path to the foundation. Brick would add a brittle element, and adding a story increases the demand.
After an earthquake, a building is posted with a yellow ATC-20 placard. What does the placard mean?
- a.Unsafe: do not enter or occupy except as authorized by the jurisdiction
- b.Condemned: the building has been ordered demolished by the owner
- c.Restricted Use: entry or occupancy is limited as stated on the placard✓
- d.Inspected: no apparent hazard and lawful occupancy is permitted
ATC-20 uses three postings: green INSPECTED, yellow RESTRICTED USE and red UNSAFE. Yellow means specific restrictions on entry, occupancy or particular areas are written on the placard. No ATC-20 placard is a demolition order; even a red tag only restricts entry pending further evaluation.
Under ATC-20, what does a red UNSAFE placard signify?
- a.The building may be occupied by the owner but not by tenants
- b.The building may not be entered or occupied except as authorized✓
- c.The building has been inspected and may be lawfully occupied without limits
- d.The building must be demolished within thirty calendar days
A red UNSAFE posting means there is an extreme hazard or the building may collapse, so entry is prohibited except as specifically authorized by the jurisdiction. It is not a demolition order: many red-tagged buildings are later repaired. Lawful occupancy corresponds to the green INSPECTED placard.
In the ATC-20 procedure, what is the purpose of the Rapid Evaluation?
- a.To determine insurance settlement amounts for the owners
- b.To prepare repair drawings and a construction cost estimate
- c.To quickly post obviously safe and obviously unsafe buildings✓
- d.To perform a nonlinear analysis of the damaged structure
The Rapid Evaluation is a brief exterior-focused screening that sorts buildings into apparently safe, obviously unsafe, and doubtful cases; doubtful ones are referred to a Detailed Evaluation, and some then to an Engineering Evaluation commissioned by the owner. Repair design and analysis happen after, not during, safety evaluation.
During an ATC-20 Detailed Evaluation, which observation in a concrete frame building most strongly suggests an UNSAFE posting?
- a.Displaced ceiling tiles in one interior corridor
- b.Hairline cracks in the plaster of nonstructural partitions
- c.A toppled bookshelf in a second-floor office
- d.Columns with wide diagonal cracks and visibly buckled bars✓
Severe diagonal (shear) cracking and buckled longitudinal bars mean the columns have lost much of their gravity and lateral capacity, a collapse hazard in aftershocks. Plaster cracks, fallen ceiling tiles and overturned contents are nonstructural damage; they may call for restricting an area but do not threaten the vertical load path.
Several precast concrete parking structures collapsed in the Northridge earthquake. Which deficiency was a principal contributor?
- a.Gravity framing and connections that could not tolerate the lateral drift✓
- b.Foundations that were supported on rock rather than on soil
- c.Shear walls that were far stronger and stiffer than the design forces required
- d.Use of cast-in-place topping slabs with too much reinforcing steel
Gravity columns and precast connections that were not part of the lateral system could not accommodate the drift, and thin toppings with brittle mesh and weak collectors could not deliver forces to the walls. The lesson is the deformation compatibility requirement of ASCE 7-16 Section 12.12.5 and stronger collector and diaphragm provisions.
A concrete column is restrained over part of its height by a partial-height masonry infill wall. Why is this a seismic vulnerability?
- a.The column becomes too flexible to attract any lateral load
- b.The infill prevents the column from carrying the gravity load
- c.The shortened clear height makes the column stiffer and shear-critical✓
- d.The infill wall removes all of the axial load and bending from the column
A 'captive' or short column has a reduced free height, so it is much stiffer, attracts more shear, and reaches its shear capacity before it can yield in flexure. The failure is brittle. Remedies include isolating the infill with a gap or jacketing the column; the infill does not relieve the column's axial load.
Two adjacent buildings with floors at different elevations are built with almost no gap between them. What earthquake hazard does this create?
- a.Resonance that cancels out the motion of both of the buildings
- b.Uplift of both buildings caused by negative pore water pressure in the soil
- c.Liquefaction of the soil that lies between the two foundations
- d.Pounding, with one building's floor slabs striking the other's columns✓
Buildings with different periods move out of phase and collide if the separation is too small; when floor levels do not align, slabs hit columns at mid-height, which can cause column shear failure. ASCE 7-16 Section 12.12.3 addresses this with minimum separations based on inelastic displacements.
Which is the most effective global strategy for retrofitting a flexible, nonductile concrete frame building?
- a.Adding new concrete shear walls to limit drift and take the lateral load✓
- b.Lengthening the period by cutting existing columns at midheight
- c.Removing floor diaphragm topping slabs to reduce the building's lateral stiffness
- d.Replacing interior doors with heavier fire-rated door assemblies
New shear walls (or braced frames) with adequate foundations and collectors stiffen the building, reduce drift on the brittle existing frames, and provide a ductile lateral system. Weakening diaphragms or cutting columns destroys the load path, and architectural changes do nothing for seismic performance.
When a tilt-up building's roof-to-wall connections are retrofitted, why are continuous crossties added across the roof diaphragm?
- a.To reduce the wind uplift demand on the roof sheathing nails at edges
- b.To raise the gravity load capacity of the roof framing for new mechanical equipment
- c.To carry wall anchorage forces across the building so framing does not pull apart✓
- d.To stiffen the wall panels against in-plane shear between panel joints
Out-of-plane wall forces must be developed into the diaphragm; continuous ties between diaphragm chords (ASCE 7-16 Section 12.11.2.2.1) keep purlins, girders and their splices from separating. They are a load path element for anchorage forces, not a gravity, wall in-plane or wind uplift upgrade.
A pre-1933 California school building of unreinforced brick would be regulated differently if rebuilt today mainly because of which historic event?
- a.The 1994 Northridge earthquake and hospital legislation of that year
- b.The 1989 Loma Prieta earthquake and the Seismic Hazards Mapping Act
- c.The 1906 San Francisco earthquake and the Alquist-Priolo Act
- d.The 1933 Long Beach earthquake, which led to the Field Act✓
Severe damage to unreinforced masonry schools in the 1933 Long Beach earthquake led California to enact the Field Act, requiring state-supervised design and construction of public schools, and the Riley Act for other buildings. The Alquist-Priolo Act (fault zoning) followed the 1971 San Fernando earthquake, not 1906.
Estimate the approximate fundamental period Ta of a steel moment-resisting frame with structural height hn = 60 ft. Use Ct = 0.028 and x = 0.8.
- a.0.29 s
- b.0.50 s
- c.0.74 s✓
- d.1.68 s
ASCE 7-16 Eq. 12.8-7: Ta = Ct x hn^x = 0.028 x 60^0.8 = 0.74 s, with hn in feet. Dropping the exponent gives 1.68 s, and multiplying by an upper-limit coefficient Cu belongs to the check on a computed period, not to Ta itself.
Estimate the approximate fundamental period Ta of a concrete moment-resisting frame with structural height hn = 48 ft. Use Ct = 0.016 and x = 0.9.
- a.0.40 s
- b.0.52 s✓
- c.0.73 s
- d.0.77 s
ASCE 7-16 Eq. 12.8-7: Ta = Ct x hn^x = 0.016 x 48^0.9 = 0.52 s, with hn in feet. Dropping the exponent gives 0.77 s, and multiplying by an upper-limit coefficient Cu belongs to the check on a computed period, not to Ta itself.
Estimate the approximate fundamental period Ta of a concrete shear wall building (classified as 'all other structural systems') with structural height hn = 40 ft. Use Ct = 0.02 and x = 0.75.
- a.0.13 s
- b.0.23 s
- c.0.25 s
- d.0.32 s✓
ASCE 7-16 Eq. 12.8-7: Ta = Ct x hn^x = 0.02 x 40^0.75 = 0.32 s, with hn in feet. Dropping the exponent gives 0.80 s, and multiplying by an upper-limit coefficient Cu belongs to the check on a computed period, not to Ta itself.
Estimate the approximate fundamental period Ta of a steel buckling-restrained braced frame with structural height hn = 75 ft. Use Ct = 0.03 and x = 0.75.
- a.0.76 s✓
- b.0.96 s
- c.1.07 s
- d.2.25 s
ASCE 7-16 Eq. 12.8-7: Ta = Ct x hn^x = 0.03 x 75^0.75 = 0.76 s, with hn in feet. Dropping the exponent gives 2.25 s, and multiplying by an upper-limit coefficient Cu belongs to the check on a computed period, not to Ta itself.
A building has approximate period Ta = 0.60 s. A properly substantiated computer analysis gives T = 1.05 s. With Cu = 1.4, what period may be used to compute base shear for strength design?
- a.0.60 s
- b.0.82 s
- c.0.84 s✓
- d.1.05 s
ASCE 7-16 Section 12.8.2 caps the computed period at Cu x Ta = 1.4 x 0.60 = 0.84 s. The analysis value of 1.05 s is longer, so the cap of 0.84 s governs. Using Ta = 0.60 s is permitted but more conservative than required, and averaging the two has no code basis.
A building has approximate period Ta = 0.45 s. A properly substantiated computer analysis gives T = 0.52 s. With Cu = 1.4, what period may be used to compute base shear for strength design?
- a.0.42 s
- b.0.45 s
- c.0.48 s
- d.0.52 s✓
ASCE 7-16 Section 12.8.2 caps the computed period at Cu x Ta = 1.4 x 0.45 = 0.63 s. The analysis value of 0.52 s is below the cap, so it may be used directly. Using Ta = 0.45 s is permitted but more conservative than required, and averaging the two has no code basis.
A building has approximate period Ta = 0.80 s. A properly substantiated computer analysis gives T = 1.40 s. With Cu = 1.5, what period may be used to compute base shear for strength design?
- a.1.20 s✓
- b.1.40 s
- c.1.50 s
- d.2.10 s
ASCE 7-16 Section 12.8.2 caps the computed period at Cu x Ta = 1.5 x 0.80 = 1.20 s. The analysis value of 1.40 s is longer, so the cap of 1.20 s governs. Using Ta = 0.80 s is permitted but more conservative than required, and averaging the two has no code basis.
Given SDS = 1g, SD1 = 0.6g, S1 = 0.6g, R = 8, Ie = 1 and T = 1.2 s (T is less than TL), what seismic response coefficient Cs governs under the equivalent lateral force procedure?
- a.0.0625✓
- b.0.0938
- c.0.1000
- d.0.1250
ASCE 7-16 Section 12.8.1.1: Cs = SDS/(R/Ie) = 0.1250; it need not exceed SD1/[T(R/Ie)] = 0.0625; it may not be less than 0.044 SDS Ie = 0.0440 (nor 0.01); and because S1 is at least 0.6g, not less than 0.5 S1/(R/Ie) = 0.0375. Here the SD1/(T R/Ie) limit governs: Cs = 0.0625. Picking the plateau value without checking the period-dependent cap, or the cap without checking the minimums, are the usual errors.
Given SDS = 1.2g, SD1 = 0.5g, S1 = 0.5g, R = 6, Ie = 1 and T = 0.3 s (T is less than TL), what seismic response coefficient Cs governs under the equivalent lateral force procedure?
- a.0.0528
- b.0.1600
- c.0.2000✓
- d.0.2778
ASCE 7-16 Section 12.8.1.1: Cs = SDS/(R/Ie) = 0.2000; it need not exceed SD1/[T(R/Ie)] = 0.2778; it may not be less than 0.044 SDS Ie = 0.0528 (nor 0.01). Here the basic SDS/(R/Ie) value governs: Cs = 0.2000. Picking the plateau value without checking the period-dependent cap, or the cap without checking the minimums, are the usual errors.
Given SDS = 0.9g, SD1 = 0.45g, S1 = 0.45g, R = 5, Ie = 1.25 and T = 0.9 s (T is less than TL), what seismic response coefficient Cs governs under the equivalent lateral force procedure?
- a.0.0495
- b.0.1250✓
- c.0.2250
- d.0.2812
ASCE 7-16 Section 12.8.1.1: Cs = SDS/(R/Ie) = 0.2250; it need not exceed SD1/[T(R/Ie)] = 0.1250; it may not be less than 0.044 SDS Ie = 0.0495 (nor 0.01). Here the SD1/(T R/Ie) limit governs: Cs = 0.1250. Picking the plateau value without checking the period-dependent cap, or the cap without checking the minimums, are the usual errors.
Given SDS = 1.4g, SD1 = 0.7g, S1 = 0.8g, R = 8, Ie = 1 and T = 2.2 s (T is less than TL), what seismic response coefficient Cs governs under the equivalent lateral force procedure?
- a.0.0398
- b.0.0493
- c.0.0616✓
- d.0.1750
ASCE 7-16 Section 12.8.1.1: Cs = SDS/(R/Ie) = 0.1750; it need not exceed SD1/[T(R/Ie)] = 0.0398; it may not be less than 0.044 SDS Ie = 0.0616 (nor 0.01); and because S1 is at least 0.6g, not less than 0.5 S1/(R/Ie) = 0.0500. Here the minimum governs: Cs = 0.0616. Picking the plateau value without checking the period-dependent cap, or the cap without checking the minimums, are the usual errors.
Given SDS = 1g, SD1 = 0.55g, S1 = 0.55g, R = 6.5, Ie = 1.5 and T = 0.25 s (T is less than TL), what seismic response coefficient Cs governs under the equivalent lateral force procedure?
- a.0.2308✓
- b.0.2885
- c.0.3462
- d.0.5077
ASCE 7-16 Section 12.8.1.1: Cs = SDS/(R/Ie) = 0.2308; it need not exceed SD1/[T(R/Ie)] = 0.5077; it may not be less than 0.044 SDS Ie = 0.0660 (nor 0.01). Here the basic SDS/(R/Ie) value governs: Cs = 0.2308. Picking the plateau value without checking the period-dependent cap, or the cap without checking the minimums, are the usual errors.
A building has an effective seismic weight W = 3,200 kips and a governing seismic response coefficient Cs = 0.125. What is the design seismic base shear?
- a.280 kips
- b.308 kips
- c.320 kips
- d.400 kips✓
ASCE 7-16 Eq. 12.8-1: V = Cs x W = 0.125 x 3,200 = 400 kips. This is a strength-level force; multiplying by 0.7 converts the earthquake effect for allowable stress design load combinations but is not the base shear itself.
A building has an effective seismic weight W = 5,400 kips and a governing seismic response coefficient Cs = 0.0962. What is the design seismic base shear?
- a.364 kips
- b.519 kips✓
- c.649 kips
- d.727 kips
ASCE 7-16 Eq. 12.8-1: V = Cs x W = 0.0962 x 5,400 = 519 kips. This is a strength-level force; multiplying by 0.7 converts the earthquake effect for allowable stress design load combinations but is not the base shear itself.
A building has an effective seismic weight W = 880 kips and a governing seismic response coefficient Cs = 0.185. What is the design seismic base shear?
- a.114 kips
- b.125 kips
- c.163 kips✓
- d.228 kips
ASCE 7-16 Eq. 12.8-1: V = Cs x W = 0.185 x 880 = 163 kips. This is a strength-level force; multiplying by 0.7 converts the earthquake effect for allowable stress design load combinations but is not the base shear itself.
Determine the effective seismic weight contributed by a single-story warehouse (storage occupancy). Area = 40,000 sq ft, dead load = 22 psf, and the design includes a storage live load of 250 psf.
- a.880 kips
- b.3,380 kips✓
- c.5,880 kips
- d.10,880 kips
ASCE 7-16 Section 12.7.2 defines W as dead load plus specific additions: here 25% of the storage live load (0.25 x 250 = 62.5 psf). W = 40,000 x (22 + 62.5) / 1000 = 3,380 kips. Dead load alone (880 kips) leaves out a mass that will really be present during the earthquake.
Determine the effective seismic weight contributed by an office floor where a partition allowance is used in design. Area = 15,000 sq ft, dead load = 85 psf, and the design includes office live load of 50 psf.
- a.1,425 kips✓
- b.1,575 kips
- c.1,781 kips
- d.1,875 kips
ASCE 7-16 Section 12.7.2 defines W as dead load plus specific additions: here the larger of actual partition weight or 10 psf of floor area (10 psf here); ordinary office live load is not included. W = 15,000 x (85 + 10) / 1000 = 1,425 kips. Dead load alone (1,275 kips) leaves out a mass that will really be present during the earthquake.
Determine the effective seismic weight contributed by a roof where the flat roof snow load exceeds 30 psf. Area = 20,000 sq ft, dead load = 30 psf, and the design includes a flat roof snow load of 60 psf.
- a.600 kips
- b.672 kips
- c.720 kips
- d.840 kips✓
ASCE 7-16 Section 12.7.2 defines W as dead load plus specific additions: here 20% of the uniform design snow load (0.20 x 60 = 12 psf) because the flat roof snow load exceeds 30 psf. W = 20,000 x (30 + 12) / 1000 = 840 kips. Dead load alone (600 kips) leaves out a mass that will really be present during the earthquake.
A 2-story building has base shear V = 300 kips. Level data — 2nd floor: w = 400 kips at h = 12 ft; roof: w = 300 kips at h = 24 ft. Using the vertical distribution exponent k = 1, what lateral force is applied at the roof?
- a.129 kips
- b.150 kips
- c.180 kips✓
- d.200 kips
ASCE 7-16 Eqs. 12.8-11 and 12.8-12: Fx = Cvx x V with Cvx = wx hx^k / sum(wi hi^k). The products are 4,800, 7,200 (sum 12,000). Cvx for the roof = 7,200/12,000 = 0.600, so Fx = 0.600 x 300 = 180 kips. Distributing by weight alone ignores height, and an equal split per level ignores both.
A 3-story building has base shear V = 500 kips. Level data — 2nd floor: w = 600 kips at h = 12 ft; 3rd floor: w = 600 kips at h = 24 ft; roof: w = 400 kips at h = 36 ft. Using the vertical distribution exponent k = 1, what lateral force is applied at the roof?
- a.125 kips
- b.167 kips
- c.200 kips✓
- d.250 kips
ASCE 7-16 Eqs. 12.8-11 and 12.8-12: Fx = Cvx x V with Cvx = wx hx^k / sum(wi hi^k). The products are 7,200, 14,400, 14,400 (sum 36,000). Cvx for the roof = 14,400/36,000 = 0.400, so Fx = 0.400 x 500 = 200 kips. Distributing by weight alone ignores height, and an equal split per level ignores both.
A 2-story building has base shear V = 240 kips. Level data — 2nd floor: w = 500 kips at h = 14 ft; roof: w = 350 kips at h = 28 ft. Using the vertical distribution exponent k = 1, what lateral force is applied at the 2nd floor?
- a.67 kips
- b.80 kips
- c.100 kips✓
- d.141 kips
ASCE 7-16 Eqs. 12.8-11 and 12.8-12: Fx = Cvx x V with Cvx = wx hx^k / sum(wi hi^k). The products are 7,000, 9,800 (sum 16,800). Cvx for the 2nd floor = 7,000/16,800 = 0.417, so Fx = 0.417 x 240 = 100 kips. Distributing by weight alone ignores height, and an equal split per level ignores both.
A 3-story building has base shear V = 800 kips. Level data — 2nd floor: w = 900 kips at h = 15 ft; 3rd floor: w = 900 kips at h = 30 ft; roof: w = 700 kips at h = 45 ft. Using the vertical distribution exponent k = 1.25, what lateral force is applied at the roof?
- a.381 kips✓
- b.400 kips
- c.457 kips
- d.476 kips
ASCE 7-16 Eqs. 12.8-11 and 12.8-12: Fx = Cvx x V with Cvx = wx hx^k / sum(wi hi^k). The products are 26,568, 63,189, 81,586 (sum 171,343). Cvx for the roof = 81,586/171,343 = 0.476, so Fx = 0.476 x 800 = 381 kips. Distributing by weight alone ignores height, and an equal split per level ignores both.
A 3-story building has base shear V = 420 kips. Level data — 2nd floor: w = 450 kips at h = 10 ft; 3rd floor: w = 450 kips at h = 20 ft; roof: w = 300 kips at h = 30 ft. Using the vertical distribution exponent k = 1, what lateral force is applied at the 3rd floor?
- a.84 kips
- b.140 kips
- c.158 kips
- d.168 kips✓
ASCE 7-16 Eqs. 12.8-11 and 12.8-12: Fx = Cvx x V with Cvx = wx hx^k / sum(wi hi^k). The products are 4,500, 9,000, 9,000 (sum 22,500). Cvx for the 3rd floor = 9,000/22,500 = 0.400, so Fx = 0.400 x 420 = 168 kips. Distributing by weight alone ignores height, and an equal split per level ignores both.
Lateral seismic forces on a 3-story building are 60 kips at level 2, 110 kips at level 3, 150 kips at roof. What is the seismic story shear in the story immediately below level 3?
- a.110 kips
- b.260 kips✓
- c.320 kips
- d.325 kips
ASCE 7-16 Eq. 12.8-13: the story shear is the sum of the lateral forces at and above that story: 110 + 150 = 260 kips. Using only the force at level 3 (110 kips) omits what is delivered from the levels above, and summing the forces below the story runs the load path backward.
Lateral seismic forces on a 4-story building are 45 kips at level 2, 85 kips at level 3, 120 kips at level 4, 150 kips at roof. What is the seismic story shear in the story immediately below level 4?
- a.120 kips
- b.270 kips✓
- c.338 kips
- d.400 kips
ASCE 7-16 Eq. 12.8-13: the story shear is the sum of the lateral forces at and above that story: 120 + 150 = 270 kips. Using only the force at level 4 (120 kips) omits what is delivered from the levels above, and summing the forces below the story runs the load path backward.
Lateral seismic forces on a 2-story building are 80 kips at level 2, 140 kips at roof. What is the seismic story shear in the story immediately below level 2?
- a.80 kips
- b.150 kips
- c.180 kips
- d.220 kips✓
ASCE 7-16 Eq. 12.8-13: the story shear is the sum of the lateral forces at and above that story: 80 + 140 = 220 kips. Using only the force at level 2 (80 kips) omits what is delivered from the levels above, and summing the forces below the story runs the load path backward.
For a diaphragm at level x: the sum of design lateral forces at and above the level is 180 kips, the sum of seismic weights at and above the level is 900 kips, and the weight tributary to the diaphragm is wpx = 450 kips. SDS = 1g, Ie = 1. What is the diaphragm design force Fpx?
- a.63 kips
- b.90 kips✓
- c.112 kips
- d.180 kips
ASCE 7-16 Eq. 12.10-1: Fpx = (sum Fi / sum wi) x wpx = (180/900) x 450 = 90 kips. Limits (Eqs. 12.10-2 and 12.10-3): minimum 0.2 SDS Ie wpx = 90 kips, maximum 0.4 SDS Ie wpx = 180 kips. Here the calculated value lies between the limits and governs: Fpx = 90 kips. Reporting the unchecked ratio value, or the story force itself, skips the bounds.
For a diaphragm at level x: the sum of design lateral forces at and above the level is 520 kips, the sum of seismic weights at and above the level is 2,400 kips, and the weight tributary to the diaphragm is wpx = 800 kips. SDS = 1.2g, Ie = 1. What is the diaphragm design force Fpx?
- a.192 kips✓
- b.240 kips
- c.384 kips
- d.520 kips
ASCE 7-16 Eq. 12.10-1: Fpx = (sum Fi / sum wi) x wpx = (520/2,400) x 800 = 173 kips. Limits (Eqs. 12.10-2 and 12.10-3): minimum 0.2 SDS Ie wpx = 192 kips, maximum 0.4 SDS Ie wpx = 384 kips. Here the minimum governs: Fpx = 192 kips. Reporting the unchecked ratio value, or the story force itself, skips the bounds.
For a diaphragm at level x: the sum of design lateral forces at and above the level is 95 kips, the sum of seismic weights at and above the level is 1,500 kips, and the weight tributary to the diaphragm is wpx = 500 kips. SDS = 1g, Ie = 1. What is the diaphragm design force Fpx?
- a.32 kips
- b.70 kips
- c.95 kips
- d.100 kips✓
ASCE 7-16 Eq. 12.10-1: Fpx = (sum Fi / sum wi) x wpx = (95/1,500) x 500 = 32 kips. Limits (Eqs. 12.10-2 and 12.10-3): minimum 0.2 SDS Ie wpx = 100 kips, maximum 0.4 SDS Ie wpx = 200 kips. Here the minimum governs: Fpx = 100 kips. Reporting the unchecked ratio value, or the story force itself, skips the bounds.
For a diaphragm at level x: the sum of design lateral forces at and above the level is 150 kips, the sum of seismic weights at and above the level is 400 kips, and the weight tributary to the diaphragm is wpx = 400 kips. SDS = 0.9g, Ie = 1.25. What is the diaphragm design force Fpx?
- a.90 kips
- b.105 kips
- c.120 kips
- d.150 kips✓
ASCE 7-16 Eq. 12.10-1: Fpx = (sum Fi / sum wi) x wpx = (150/400) x 400 = 150 kips. Limits (Eqs. 12.10-2 and 12.10-3): minimum 0.2 SDS Ie wpx = 90 kips, maximum 0.4 SDS Ie wpx = 180 kips. Here the calculated value lies between the limits and governs: Fpx = 150 kips. Reporting the unchecked ratio value, or the story force itself, skips the bounds.
For a diaphragm at level x: the sum of design lateral forces at and above the level is 640 kips, the sum of seismic weights at and above the level is 1,600 kips, and the weight tributary to the diaphragm is wpx = 500 kips. SDS = 1.1g, Ie = 1. What is the diaphragm design force Fpx?
- a.200 kips✓
- b.220 kips
- c.250 kips
- d.640 kips
ASCE 7-16 Eq. 12.10-1: Fpx = (sum Fi / sum wi) x wpx = (640/1,600) x 500 = 200 kips. Limits (Eqs. 12.10-2 and 12.10-3): minimum 0.2 SDS Ie wpx = 110 kips, maximum 0.4 SDS Ie wpx = 220 kips. Here the calculated value lies between the limits and governs: Fpx = 200 kips. Reporting the unchecked ratio value, or the story force itself, skips the bounds.
A structural wall weighing 90 psf must be designed for an out-of-plane seismic force. With SDS = 1g and Ie = 1, what is the minimum design force normal to the wall surface?
- a.18.0 psf
- b.27.0 psf
- c.28.8 psf
- d.36.0 psf✓
ASCE 7-16 Section 12.11.1: Fp = 0.4 SDS Ie x (wall weight) = 0.4 x 1 x 1 x 90 = 36.0 psf, but not less than 10% of the wall weight (9.0 psf). Design force = 36.0 psf. This out-of-plane wall design force is separate from the larger wall anchorage force of Section 12.11.2.
A structural wall weighing 75 psf must be designed for an out-of-plane seismic force. With SDS = 1.2g and Ie = 1.25, what is the minimum design force normal to the wall surface?
- a.22.5 psf
- b.45.0 psf✓
- c.56.2 psf
- d.90.0 psf
ASCE 7-16 Section 12.11.1: Fp = 0.4 SDS Ie x (wall weight) = 0.4 x 1.2 x 1.25 x 75 = 45.0 psf, but not less than 10% of the wall weight (7.5 psf). Design force = 45.0 psf. This out-of-plane wall design force is separate from the larger wall anchorage force of Section 12.11.2.
A structural wall weighing 80 psf must be designed for an out-of-plane seismic force. With SDS = 0.15g and Ie = 1, what is the minimum design force normal to the wall surface?
- a.8.0 psf✓
- b.10.0 psf
- c.12.0 psf
- d.16.0 psf
ASCE 7-16 Section 12.11.1: Fp = 0.4 SDS Ie x (wall weight) = 0.4 x 0.15 x 1 x 80 = 4.8 psf, but not less than 10% of the wall weight (8.0 psf). Design force = 8.0 psf. The 10% floor governs at this low SDS. This out-of-plane wall design force is separate from the larger wall anchorage force of Section 12.11.2.