California Civil Engineer: Seismic Principles — All Questions
24 questions
Elastic analysis under the design seismic forces gives a story drift of 0.45 in. for a story 13 ft high. The system has Cd = 5.5 and the building has Ie = 1. What is the design story drift to compare with the allowable drift?
- a.2.48 in.✓
- b.3.09 in.
- c.3.71 in.
- d.4.95 in.
ASCE 7-16 Eq. 12.8-15 amplifies the elastic displacement: delta = Cd x delta_xe / Ie = 5.5 x 0.45 / 1 = 2.48 in. Reporting 0.45 in. ignores inelastic amplification; multiplying by Ie instead of dividing double-counts importance, which is already in the forces that produced delta_xe.
Elastic analysis under the design seismic forces gives a story drift of 0.30 in. for a story 12 ft high. The system has Cd = 5 and the building has Ie = 1.25. What is the design story drift to compare with the allowable drift?
- a.0.30 in.
- b.0.60 in.
- c.1.20 in.✓
- d.1.88 in.
ASCE 7-16 Eq. 12.8-15 amplifies the elastic displacement: delta = Cd x delta_xe / Ie = 5 x 0.30 / 1.25 = 1.20 in. Reporting 0.30 in. ignores inelastic amplification; multiplying by Ie instead of dividing double-counts importance, which is already in the forces that produced delta_xe.
Elastic analysis under the design seismic forces gives a story drift of 0.52 in. for a story 10 ft high. The system has Cd = 4 and the building has Ie = 1. What is the design story drift to compare with the allowable drift?
- a.0.52 in.
- b.2.08 in.✓
- c.2.60 in.
- d.3.12 in.
ASCE 7-16 Eq. 12.8-15 amplifies the elastic displacement: delta = Cd x delta_xe / Ie = 4 x 0.52 / 1 = 2.08 in. Reporting 0.52 in. ignores inelastic amplification; multiplying by Ie instead of dividing double-counts importance, which is already in the forces that produced delta_xe.
Elastic analysis under the design seismic forces gives a story drift of 0.20 in. for a story 14 ft high. The system has Cd = 5 and the building has Ie = 1.5. What is the design story drift to compare with the allowable drift?
- a.0.20 in.
- b.0.40 in.
- c.0.47 in.
- d.0.67 in.✓
ASCE 7-16 Eq. 12.8-15 amplifies the elastic displacement: delta = Cd x delta_xe / Ie = 5 x 0.20 / 1.5 = 0.67 in. Reporting 0.20 in. ignores inelastic amplification; multiplying by Ie instead of dividing double-counts importance, which is already in the forces that produced delta_xe.
At a story, total unfactored vertical load above is Px = 2,400 kips, design story drift is 1.8 in., story shear is Vx = 310 kips, story height is 144 in., Cd = 5.5 and Ie = 1. What is the stability coefficient theta?
- a.0.009
- b.0.012
- c.0.014
- d.0.018✓
ASCE 7-16 Eq. 12.8-16: theta = Px x Delta x Ie / (Vx x hsx x Cd) = (2,400 x 1.8 x 1) / (310 x 144 x 5.5) = 0.018. Leaving Cd out of the denominator gives 0.097, which overstates theta. P-delta effects need not be considered when theta is 0.10 or less.
At a story, total unfactored vertical load above is Px = 5,200 kips, design story drift is 2.2 in., story shear is Vx = 420 kips, story height is 156 in., Cd = 5 and Ie = 1. What is the stability coefficient theta?
- a.0.035✓
- b.0.087
- c.0.175
- d.0.218
ASCE 7-16 Eq. 12.8-16: theta = Px x Delta x Ie / (Vx x hsx x Cd) = (5,200 x 2.2 x 1) / (420 x 156 x 5) = 0.035. Leaving Cd out of the denominator gives 0.175, which overstates theta. P-delta effects need not be considered when theta is 0.10 or less.
At a story, total unfactored vertical load above is Px = 3,600 kips, design story drift is 1.5 in., story shear is Vx = 500 kips, story height is 144 in., Cd = 4 and Ie = 1.25. What is the stability coefficient theta?
- a.0.012
- b.0.016
- c.0.019
- d.0.023✓
ASCE 7-16 Eq. 12.8-16: theta = Px x Delta x Ie / (Vx x hsx x Cd) = (3,600 x 1.5 x 1.25) / (500 x 144 x 4) = 6,750 / 288,000 = 0.023. Leaving Cd out of the denominator gives 6,750 / 72,000 = 0.094, which overstates theta fourfold. P-delta effects need not be considered when theta is 0.10 or less.
For a story with shear demand-to-capacity ratio beta = 1 in a system with Cd = 5.5, what is the maximum permitted stability coefficient theta_max?
- a.0.061
- b.0.073
- c.0.091✓
- d.0.250
ASCE 7-16 Eq. 12.8-17: theta_max = 0.5/(beta x Cd) = 0.5/(1 x 5.5) = 0.091, and it may not exceed 0.25. The value 0.10 is only the threshold above which P-delta effects must be included, and 0.25 is the absolute cap, which does not govern here.
For a story with shear demand-to-capacity ratio beta = 0.8 in a system with Cd = 4, what is the maximum permitted stability coefficient theta_max?
- a.0.156✓
- b.0.195
- c.0.250
- d.0.312
ASCE 7-16 Eq. 12.8-17: theta_max = 0.5/(beta x Cd) = 0.5/(0.8 x 4) = 0.156, and it may not exceed 0.25. The value 0.10 is only the threshold above which P-delta effects must be included, and 0.25 is the absolute cap, which does not govern here.
Two adjacent buildings on the same property (both Ie = 1.0) have maximum elastic displacements at the level of the shorter roof of 0.8 in. (Cd = 5.5) and 0.5 in. (Cd = 5). What minimum separation is required between them?
- a.0.94 in.
- b.5.06 in.✓
- c.6.33 in.
- d.6.90 in.
ASCE 7-16 Section 12.12.3: each inelastic displacement is delta_M = Cd x delta_max / Ie, giving 4.40 in. and 2.50 in. Buildings on the same property are separated by the SRSS: sqrt(4.40^2 + 2.50^2) = 5.06 in. The absolute sum 6.90 in. is more than the code requires, and combining the elastic values (0.94 in.) ignores Cd.
Two adjacent buildings on the same property (both Ie = 1.0) have maximum elastic displacements at the level of the shorter roof of 1.2 in. (Cd = 4) and 0.9 in. (Cd = 4). What minimum separation is required between them?
- a.6.00 in.✓
- b.7.50 in.
- c.8.40 in.
- d.9.00 in.
ASCE 7-16 Section 12.12.3: each inelastic displacement is delta_M = Cd x delta_max / Ie, giving 4.80 in. and 3.60 in. Buildings on the same property are separated by the SRSS: sqrt(4.80^2 + 3.60^2) = 6.00 in. The absolute sum 8.40 in. is more than the code requires, and combining the elastic values (1.50 in.) ignores Cd.
Two adjacent buildings on the same property (both Ie = 1.0) have maximum elastic displacements at the level of the shorter roof of 0.6 in. (Cd = 5) and 0.6 in. (Cd = 5.5). What minimum separation is required between them?
- a.4.46 in.✓
- b.5.57 in.
- c.6.30 in.
- d.6.69 in.
ASCE 7-16 Section 12.12.3: each inelastic displacement is delta_M = Cd x delta_max / Ie, giving 3.00 in. and 3.30 in. Buildings on the same property are separated by the SRSS: sqrt(3.00^2 + 3.30^2) = 4.46 in. The absolute sum 6.30 in. is more than the code requires, and combining the elastic values (0.85 in.) ignores Cd.
What does the response modification coefficient R represent in seismic design?
- a.The reliability penalty applied to systems with few lateral elements
- b.The ratio of actual system strength to the design-level strength
- c.The amplification of elastic drift needed to estimate the true inelastic displacement
- d.The reduction of elastic force demand allowed for ductility and overstrength✓
R (ASCE 7-16 Table 12.2-1) divides the elastic demand because a well-detailed system dissipates energy inelastically and has reserve strength. Amplifying drift is the job of Cd, the strength ratio is the overstrength factor, and the reliability penalty is the redundancy factor rho.
In a building frame system, how are gravity and lateral loads carried?
- a.Bearing walls carry gravity and also resist all of the lateral load
- b.Cantilevered columns carry gravity load and also resist all of the lateral load
- c.A frame carries gravity; shear walls or braced frames resist lateral load✓
- d.Moment frames resist both gravity load and all of the lateral load
ASCE 7-16 Section 11.2 defines a building frame system as an essentially complete space frame for gravity with shear walls or braced frames for seismic resistance. If the walls carry significant gravity load, it is a bearing wall system with a lower R; a frame resisting both by flexure is a moment-resisting frame system.
In a dual system, the moment frames must be capable of resisting at least what share of the design seismic forces?
- a.75%
- b.25%✓
- c.50%
- d.10%
ASCE 7-16 Section 12.2.5.1 requires the moment frames of a dual system to resist at least 25% of the design seismic forces as a backup to the walls or braced frames, with total resistance shared in proportion to rigidity. Lower values would not provide a meaningful second line of defense; higher ones are not required.
A story's lateral stiffness is 65% of the stiffness of the story above. Which vertical irregularity exists?
- a.Weight (mass) irregularity
- b.Stiffness-soft story irregularity✓
- c.Vertical geometric irregularity
- d.In-plane discontinuity irregularity
ASCE 7-16 Table 12.3-2 defines a soft story where lateral stiffness is less than 70% of the story above (or less than 80% of the average of the three stories above). Mass irregularity compares story weights (more than 150%), and vertical geometric irregularity compares horizontal dimensions of the lateral system (more than 130%).
A story's lateral strength is 75% of the strength of the story above. How is this condition classified?
- a.Soft story irregularity
- b.Weak story irregularity✓
- c.Torsional irregularity
- d.Mass irregularity
ASCE 7-16 Table 12.3-2: a weak story has lateral strength less than 80% of the story above (extreme if less than 65%). A soft story is a stiffness comparison, not a strength comparison; the two often occur together, as in open-front tuck-under parking, but are checked separately.
With accidental torsion included, the maximum story drift at one end of a rigid-diaphragm building is 1.3 times the average of the drifts at the two ends. What does this indicate?
- a.Torsional irregularity (ratio above 1.2)✓
- b.Extreme torsional irregularity (above 1.2)
- c.No irregularity (ratio is below 1.5)
- d.Reentrant corner irregularity (above 1.15)
ASCE 7-16 Table 12.3-1: torsional irregularity exists when the maximum drift exceeds 1.2 times the average; extreme torsional irregularity begins at 1.4. A ratio of 1.3 is therefore irregular but not extreme. Reentrant corners are a plan-geometry test (both projections more than 15% of the plan dimension).
A floor diaphragm has an opening equal to 55% of its gross enclosed area. Which horizontal irregularity applies?
- a.Reentrant corner irregularity
- b.Nonparallel system irregularity
- c.Diaphragm discontinuity irregularity✓
- d.Out-of-plane offset discontinuity irregularity
ASCE 7-16 Table 12.3-1 defines diaphragm discontinuity as a cutout or open area greater than 50% of the gross enclosed diaphragm area (or a stiffness change of more than 50% between stories). Out-of-plane offset refers to vertical elements shifting out of their plane, and nonparallel systems to elements not aligned with the major axes.
For a Seismic Design Category D building, what value of the redundancy factor rho applies when the conditions for the lower value are NOT met?
- a.2.0
- b.1.3✓
- c.1.5
- d.1.0
ASCE 7-16 Section 12.3.4.2 sets rho = 1.3 for SDC D through F unless the structure qualifies for 1.0 (for example, removal of an individual element does not cut story strength by more than 33% or create extreme torsional irregularity). Rho is always 1.0 in SDC B and C.
For which calculation is the redundancy factor rho permitted to be taken as 1.0 even in Seismic Design Category D?
- a.Braced frame member design
- b.Drift and P-delta calculations✓
- c.Shear wall strength design
- d.Foundation overturning design
ASCE 7-16 Section 12.3.4.1 lists cases where rho is 1.0, including drift and P-delta calculations, nonstructural component design, and members designed with overstrength load combinations. Strength design of the walls, frames and their foundations is exactly where the 1.3 penalty applies.
What is the allowable story drift for a typical Risk Category II steel office building more than four stories tall?
- a.0.010 times the story height
- b.0.015 times the story height
- c.0.020 times the story height✓
- d.0.025 times the story height
ASCE 7-16 Table 12.12-1 allows 0.020hsx for 'all other structures' in Risk Category I or II. The 0.025hsx limit is reserved for buildings of four stories or fewer with interior finishes designed to accommodate drift; 0.015hsx and 0.010hsx apply to Risk Categories III and IV.
A new building is set back from an interior property line. What minimum setback from the property line does ASCE 7-16 require for seismic separation?
- a.The SRSS of both buildings' elastic displacements
- b.The building's own maximum inelastic displacement✓
- c.Twice the building's computed elastic displacement
- d.One percent of the structural height of the building
ASCE 7-16 Section 12.12.3: at a property line not common to a public way, the structure is set back at least its own maximum inelastic response displacement delta_M. The SRSS combination is for two buildings on the same property, and it uses inelastic rather than elastic displacements.
What is the purpose of the deflection amplification factor Cd?
- a.To estimate inelastic displacement from an elastic analysis under reduced forces✓
- b.To raise design forces for buildings with a higher risk category
- c.To estimate the peak force that a yielding system can deliver to its connections
- d.To convert strength-level forces into allowable stress design forces
Design forces are reduced by R, so the elastic analysis displacement understates what the yielding structure will really do; multiplying by Cd (and dividing by Ie) per ASCE 7-16 Section 12.8.6 recovers the expected inelastic displacement. Peak deliverable force is addressed by the overstrength factor, and risk category by Ie.