California Civil Engineer: Seismic Principles — All Questions
24 questions
A site has a mapped risk-targeted short-period spectral acceleration Ss = 1.50g and a short-period site coefficient Fa = 1. What is the design spectral response acceleration SDS?
- a.0.750g
- b.1.000g✓
- c.1.500g
- d.2.250g
ASCE 7-16 Section 11.4.4 adjusts the mapped value for site class: SMS = Fa x Ss = 1 x 1.50 = 1.500g. Section 11.4.5 then takes two-thirds of it: SDS = (2/3)(1.500) = 1.000g. Stopping at 1.500g reports the MCER value SMS, not the design value, and multiplying by 1.5 inverts the two-thirds factor.
A site has a mapped risk-targeted short-period spectral acceleration Ss = 1.25g and a short-period site coefficient Fa = 1.2. What is the design spectral response acceleration SDS?
- a.0.667g
- b.0.833g
- c.1.000g✓
- d.1.500g
ASCE 7-16 Section 11.4.4 adjusts the mapped value for site class: SMS = Fa x Ss = 1.2 x 1.25 = 1.500g. Section 11.4.5 then takes two-thirds of it: SDS = (2/3)(1.500) = 1.000g. Stopping at 1.500g reports the MCER value SMS, not the design value, and multiplying by 1.5 inverts the two-thirds factor.
A site has a mapped risk-targeted short-period spectral acceleration Ss = 0.90g and a short-period site coefficient Fa = 1.14. What is the design spectral response acceleration SDS?
- a.0.274g
- b.0.480g
- c.0.600g
- d.0.684g✓
ASCE 7-16 Section 11.4.4 adjusts the mapped value for site class: SMS = Fa x Ss = 1.14 x 0.90 = 1.026g. Section 11.4.5 then takes two-thirds of it: SDS = (2/3)(1.026) = 0.684g. Stopping at 1.026g reports the MCER value SMS, not the design value, and multiplying by 1.5 inverts the two-thirds factor.
A site has a mapped risk-targeted short-period spectral acceleration Ss = 2.00g and a short-period site coefficient Fa = 1.2. What is the design spectral response acceleration SDS?
- a.1.333g
- b.1.600g✓
- c.2.400g
- d.3.600g
ASCE 7-16 Section 11.4.4 adjusts the mapped value for site class: SMS = Fa x Ss = 1.2 x 2.00 = 2.400g. Section 11.4.5 then takes two-thirds of it: SDS = (2/3)(2.400) = 1.600g. Stopping at 2.400g reports the MCER value SMS, not the design value, and multiplying by 1.5 inverts the two-thirds factor.
For a site with mapped 1-second spectral acceleration S1 = 0.60g and long-period site coefficient Fv = 1.7, what is the design 1-second spectral acceleration SD1?
- a.0.353g
- b.0.400g
- c.0.680g✓
- d.1.020g
SM1 = Fv x S1 = 1.7 x 0.60 = 1.020g (ASCE 7-16 Sec. 11.4.4), and SD1 = (2/3)SM1 = 0.680g (Sec. 11.4.5). 1.020g is the MCER-level value before the two-thirds reduction, and 0.400g ignores the site coefficient altogether.
For a site with mapped 1-second spectral acceleration S1 = 0.45g and long-period site coefficient Fv = 1.85, what is the design 1-second spectral acceleration SD1?
- a.0.243g
- b.0.300g
- c.0.555g✓
- d.0.833g
SM1 = Fv x S1 = 1.85 x 0.45 = 0.833g (ASCE 7-16 Sec. 11.4.4), and SD1 = (2/3)SM1 = 0.555g (Sec. 11.4.5). 0.833g is the MCER-level value before the two-thirds reduction, and 0.300g ignores the site coefficient altogether.
For a site with mapped 1-second spectral acceleration S1 = 0.75g and long-period site coefficient Fv = 1.7, what is the design 1-second spectral acceleration SD1?
- a.0.850g✓
- b.1.062g
- c.1.275g
- d.1.912g
SM1 = Fv x S1 = 1.7 x 0.75 = 1.275g (ASCE 7-16 Sec. 11.4.4), and SD1 = (2/3)SM1 = 0.850g (Sec. 11.4.5). 1.275g is the MCER-level value before the two-thirds reduction, and 0.500g ignores the site coefficient altogether.
A design response spectrum is built with SDS = 1.00g and SD1 = 0.60g. At what period Ts does the constant-acceleration plateau end and the 1/T descending branch begin?
- a.0.60 s✓
- b.0.75 s
- c.1.20 s
- d.1.67 s
ASCE 7-16 Section 11.4.6 defines Ts = SD1/SDS = 0.60/1.00 = 0.60 s. The value 0.12 s is T0 = 0.2Ts, where the plateau starts rather than ends, and 1.67 s inverts the ratio.
A design response spectrum is built with SDS = 1.20g and SD1 = 0.54g. At what period Ts does the constant-acceleration plateau end and the 1/T descending branch begin?
- a.0.09 s
- b.0.30 s
- c.0.36 s
- d.0.45 s✓
ASCE 7-16 Section 11.4.6 defines Ts = SD1/SDS = 0.54/1.20 = 0.45 s. The value 0.09 s is T0 = 0.2Ts, where the plateau starts rather than ends, and 2.22 s inverts the ratio.
A design response spectrum is built with SDS = 0.80g and SD1 = 0.50g. At what period Ts does the constant-acceleration plateau end and the 1/T descending branch begin?
- a.0.12 s
- b.0.62 s✓
- c.1.25 s
- d.1.60 s
ASCE 7-16 Section 11.4.6 defines Ts = SD1/SDS = 0.50/0.80 = 0.62 s. The value 0.12 s is T0 = 0.2Ts, where the plateau starts rather than ends, and 1.60 s inverts the ratio.
Soil properties at a building site are not known in enough detail to classify the site. Which site class does ASCE 7-16 direct the engineer to assume unless the building official or geotechnical data indicate softer soil?
- a.Site Class D✓
- b.Site Class C
- c.Site Class B
- d.Site Class E
ASCE 7-16 Section 11.4.3 makes Site Class D (stiff soil) the default when soil properties are not known in sufficient detail. Site Class B (rock) would be unconservative because rock sites take no amplification, and Site Class E is assumed only when the building official or geotechnical data point to soft clay.
Site class is assigned from average soil properties measured over what depth below the site surface?
- a.The upper 30 ft of the site profile
- b.The full depth down to bedrock
- c.The depth of the foundation only
- d.The upper 100 ft of the site profile✓
ASCE 7-16 Chapter 20 classifies the site from shear wave velocity, penetration resistance or undrained shear strength averaged over the top 100 ft (30 m). Thirty feet confuses 30 m with 30 ft, and the foundation depth alone ignores the deeper soil column that filters and amplifies the motion.
Which soil condition generally places a site in Site Class F, calling for a site response analysis rather than tabulated site coefficients?
- a.Soils vulnerable to failure, such as liquefiable soils✓
- b.Competent rock with little weathering
- c.Very dense soil and soft rock with high shear wave velocity
- d.Stiff soil with moderate blow counts
ASCE 7-16 Section 20.3.1 assigns Site Class F to soils vulnerable to potential failure or collapse under seismic loading (liquefiable soils, quick clays, peats, very thick soft clays), and Section 11.4.8 then requires a site response analysis. Very dense soil is Site Class C and stiff soil is Site Class D, both handled with site coefficients.
Under the California Building Code risk category table, which building is assigned to Risk Category IV?
- a.A three-story office building
- b.A retail store with 200 occupants
- c.A barn used only for the storage of harvested field crops
- d.A fire station that houses emergency vehicles✓
CBC Table 1604.5 places essential facilities such as fire, rescue and police stations and hospitals with emergency treatment in Risk Category IV. An ordinary office or small retail building is Risk Category II, and an agricultural storage building is Risk Category I.
What seismic importance factor Ie applies to a Risk Category III building?
- a.1.00
- b.1.15
- c.1.50
- d.1.25✓
ASCE 7-16 Table 1.5-2 assigns Ie = 1.25 to Risk Category III. Risk Categories I and II use 1.00 and Risk Category IV uses 1.50; 1.15 is a wind/snow-type factor that does not appear in the seismic column.
A Risk Category II building has SDS = 0.62g and SD1 = 0.18g, and S1 is less than 0.75g. SDS of 0.50g or more corresponds to SDC D, while SD1 between 0.133g and 0.20g corresponds to SDC C. Which Seismic Design Category applies?
- a.SDC B, by averaging the two results
- b.SDC C, because SD1 always governs
- c.SDC C, the less severe of the two
- d.SDC D, the more severe of the two✓
ASCE 7-16 Section 11.6 assigns the more severe category from the short-period and 1-second tables, so SDC D governs. Taking the less severe result or averaging has no basis; the limited exception that lets SDS alone govern applies only to short-period buildings meeting specific conditions.
A Risk Category IV hospital is located where the mapped S1 is 0.80g. Which Seismic Design Category is assigned?
- a.SDC F✓
- b.SDC E
- c.SDC C
- d.SDC D
ASCE 7-16 Section 11.6: where S1 is 0.75g or greater, Risk Category I, II and III structures are SDC E and Risk Category IV structures are SDC F. SDC D is the highest category that the SDS/SD1 tables alone can produce, so it understates this near-fault site.
The risk-targeted maximum considered earthquake (MCER) ground motions in ASCE 7-16 are defined to produce what target?
- a.A 5% probability of collapse in 10 years
- b.A 10% probability of collapse in 50 years
- c.A 2% probability of damage in 100 years
- d.A 1% probability of collapse in 50 years✓
ASCE 7-16 Chapter 21 and the Section 11.2 definition describe MCER motions as risk-targeted: a 1% probability of collapse within a 50-year period for an ordinary building. The 10%-in-50-year figure is the older design-basis hazard level for ground motion exceedance, not a collapse risk.
Which combination of conditions makes soil most susceptible to liquefaction during strong shaking?
- a.Dense, dry, well-graded gravel far above the water table
- b.Stiff, overconsolidated clay at depth
- c.Loose, saturated, clean sand near the surface✓
- d.Weathered rock with a thin soil cover
Liquefaction occurs when cyclic shaking raises pore water pressure in loose, saturated, cohesionless soil until effective stress and shear strength are lost. Dense or dry granular soils do not build up that pore pressure, and stiff clays do not liquefy in the classic sense.
A site-specific geotechnical report evaluates liquefaction potential for a Seismic Design Category D building. Which ground motion parameter does ASCE 7-16 direct be used for that evaluation?
- a.The seismic response coefficient Cs
- b.Peak ground acceleration adjusted for site effects✓
- c.The mapped long-period transition TL
- d.The design 1-second spectral acceleration SD1 without adjustment
ASCE 7-16 Section 11.8.3 requires liquefaction evaluation for the MCEG peak ground acceleration adjusted for site class (PGAM = FPGA x PGA) or a site-specific value. Cs is a building base shear coefficient that includes R, and TL is a period, not an acceleration.
For periods longer than the long-period transition period TL, how does the design spectral acceleration vary with period T?
- a.It rises in proportion to T
- b.It remains constant at SD1
- c.In proportion to 1/T
- d.In proportion to 1/T squared✓
ASCE 7-16 Section 11.4.6: beyond TL the spectrum follows Sa = SD1 x TL / T^2, the constant-displacement branch. The 1/T form applies between Ts and TL (constant velocity), and the spectrum is flat only on the short-period plateau at SDS.
Compared with a rock site, how does a soft soil site generally change the ground motion that a long-period building experiences?
- a.It amplifies long-period motion, raising Fv✓
- b.It has no effect once S1 is determined
- c.It filters out long-period motion entirely
- d.It lowers Fv below the value used for rock
Soft soil deposits amplify long-period shaking, which is why the long-period site coefficient Fv in ASCE 7-16 Section 11.4.4 increases from rock toward soft soil. Mexico City (1985) and the San Francisco Marina and Oakland (1989) are the classic examples; the mapped S1 is a rock-site value that must still be adjusted.
When the default Site Class D is assumed because soil data are lacking, what additional restriction does ASCE 7-16 place on the short-period site coefficient?
- a.Fa may not be taken as more than 1.2
- b.Fa must be taken as exactly 1.0
- c.Fa is replaced by the coefficient Fv
- d.Fa may not be taken as less than 1.2✓
ASCE 7-16 Section 11.4.4 sets a floor of Fa = 1.2 when Site Class D is selected as the default, because an unverified site could behave like Site Class C, where short-period amplification can be higher. A value of 1.0 would apply to measured Site Class D at high Ss, not to a default assumption.
For periods shorter than T0, how is the design response spectrum defined?
- a.It ramps linearly from 0.4SDS at T = 0 up to SDS at T0✓
- b.It falls from SDS at T = 0 down to 0.4SDS at T0
- c.It stays constant at SDS from T = 0 up to T0
- d.It ramps linearly from zero at T = 0 up to SDS at T0
ASCE 7-16 Section 11.4.6: for T less than T0, Sa = SDS(0.4 + 0.6T/T0), a linear ramp starting at 0.4SDS (the effective peak ground acceleration) and reaching the plateau at T0 = 0.2Ts. It does not start at zero, because a perfectly rigid object still feels the ground acceleration.