Seismic Forces: Building Structures
Together with analysis procedures this is the heart of the exam. You must be able to run the equivalent lateral force procedure quickly and correctly from values given in the stem.
Base shear
The seismic base shear is V = Cs·W (ASCE 7-16 Section 12.8.1). The coefficient starts at Cs = SDS/(R/Ie), is capped by SD1/(T·(R/Ie)) for periods up to TL, and may not be less than 0.044·SDS·Ie or 0.01; where S1 is 0.6 or more a further minimum of 0.5·S1/(R/Ie) applies. W is the effective seismic weight: dead load plus the listed portions of storage live load, partitions, permanent equipment and, where required, snow.
Vertical distribution and story shear
The base shear is distributed to the levels with Fx = Cvx·V, where Cvx = wx·hx^k / Σ(wi·hi^k) (Section 12.8.3). The exponent k is 1 for periods of 0.5 s or less, 2 for 2.5 s or more, and interpolated between. Story shear at any level is the sum of the forces above it, and the overturning moment is the sum of each force times its height above the level considered.
Load combinations and redundancy
The horizontal seismic load effect is Eh = ρ·QE and the vertical effect is Ev = 0.2·SDS·D (Section 12.4). The redundancy factor ρ is 1.0 or 1.3 depending on the Seismic Design Category and the configuration of the lateral system (Section 12.3.4). Where overstrength is required, Emh = Ω0·QE replaces Eh. These feed the strength combinations 1.2D + Ev + Eh + L + 0.2S and 0.9D − Ev + Eh.