Chapter 3 of 76% of exam

Seismic Vulnerability and Improvement of Structural Systems

This small area looks at why buildings have failed in past California earthquakes and what is done about it, including post-earthquake safety evaluation.

Irregularities and known weaknesses

Soft or weak stories, torsional irregularity, re-entrant corners, discontinuous shear walls and short columns concentrate demand and have caused repeated failures. ASCE 7-16 Section 12.3 classifies horizontal and vertical irregularities and attaches penalties or prohibitions in higher Seismic Design Categories. Older unreinforced masonry, non-ductile concrete frames, tilt-up buildings with weak wall anchorage and soft-story wood buildings are the classic vulnerable types.

Retrofit strategies

Strengthening adds or improves elements along the load path: new shear walls or braced frames, plywood sheathing on cripple walls, anchor bolts and hold-downs, wall-to-diaphragm ties, collectors and column jacketing. Other strategies reduce demand, for example base isolation or added damping. The right choice depends on which link in the load path is deficient.

Post-earthquake evaluation

The test plan references ATC-20 and ATC-20-1 for rapid and detailed safety evaluation of buildings after an earthquake. Evaluators post a placard: Inspected (green), Restricted Use (yellow) or Unsafe (red), based on observed damage and the risk from aftershocks. Know what each posting means and that the evaluation concerns safety for occupancy, not repair cost.