Safety
Cal/OSHA's Title 8 governs the program, electrical work practices, ladders, lifts, confined spaces, dust and heat on every C-7 job. CSLB weights this section at 15%. For worked examples, named traps and a full practice exam at CSLB's weights, see the PrepPass C-7 Low Voltage Systems study guide.
Programs and electrical work
Written IIPP; qualified persons; lockout and tagout.
IIPP
Written program with inspections, investigation, correction and training.
Cal. Code Regs. tit. 8 §§1509, 3203Under 50 volts
Gloves may be omitted only after a qualified person's determination.
Cal. Code Regs. tit. 8 §2320.2Locks
Removed only by the person who placed them.
Cal. Code Regs. tit. 8 §2320.5Access and hazards
Ladders, lifts, manholes, silica, asbestos and heat.
Ladders
Foot out 1/4 of working length; 36 inches above the landing.
Cal. Code Regs. tit. 8 §3276Fall protection
Over 7½ feet in construction; free fall no more than 6 feet.
Cal. Code Regs. tit. 8 §1670Heat
Outdoors: shade above 80°F, high-heat procedures at 95°F. Indoors: the indoor heat standard applies at 82°F.
Cal. Code Regs. tit. 8 §§3395, 3396