Chapter 4 of 7

OSHA Construction Safety

The master outline includes federal construction safety rules, because the master is the one responsible for the crew. The citations are to 29 CFR Part 1926: Subpart P for excavations, Subpart L for scaffolds, Subpart J for welding and cutting, and Subparts E and I for protective equipment and tools.

Trenches and excavations

A competent person can identify existing and predictable hazards and has authority to correct them. That person inspects the excavation daily and after every rainstorm. Cave-in protection is required unless the excavation is in stable rock or is less than 5 feet deep with no sign of a potential cave-in.

Egress
Ladder, stairway or ramp in trenches 4 feet or deeper, within 25 feet of lateral travel.
29 CFR 1926.651(c)(2)
Protective systems
Required at 5 feet; designed by a registered professional engineer above 20 feet.
29 CFR 1926.652
Spoil
Kept at least 2 feet from the edge.
29 CFR 1926.651(j)(2)
Atmosphere
Tested where hazards are expected in excavations over 4 feet; oxygen below 19.5 percent is deficient; flammable gas kept to 20 percent of the lower flammable limit.
29 CFR 1926.651(g)
Slopes
Type A 3/4 to 1; Type B 1 to 1; Type C 1-1/2 to 1.
29 CFR 1926 Subpart P, Appendix B
Shields
Excavation no more than 2 feet below the bottom of the shield.
29 CFR 1926.652(g)(2)

Scaffolds

Platforms are at least 18 inches wide and are inspected by a competent person before each shift.

Fall protection
Required more than 10 feet above a lower level.
29 CFR 1926.451(g)(1)
Tipping
Supported scaffolds taller than 4 times the base width are tied, guyed or braced.
29 CFR 1926.451(c)(1)
Access
Required where the platform is more than 2 feet above or below the access point.
29 CFR 1926.451(e)(1)
Power lines
10 feet from uninsulated lines under 50 kV.
29 CFR 1926.451(f)(6)
Toeboards
At least 3-1/2 inches high.
29 CFR 1926.451(h)(4)

Cylinders, torches and tools

Cylinders are capped when moved, stored upright and kept out of confined spaces. Oxygen is kept away from oil and grease.

Storage separation
Oxygen 20 feet from fuel gas, or a 5-foot noncombustible barrier rated one-half hour.
29 CFR 1926.350(a)(10)
Fuel-gas valve
Opened no more than 1-1/2 turns.
29 CFR 1926.350(d)
Compressed air
Cleaning only below 30 psi with chip guarding and protective equipment.
29 CFR 1926.302(b)(4)
Electric tools
Double insulated or grounded.
29 CFR 1926.302(a)
Grinder work rest
Within 1/8 inch of the wheel.
29 CFR 1926.303(c)(2)