  1. 1. Plumbing License Law and Board Rules

    Under Occupations Code §1301.002, a journeyman plumber with no apprenticeship programme behind them qualifies to sit for the master plumber exam after working as a journeyman for at least:

    • a.Eight years
    • b.Two years
    • c.Six months
    • d.Four years

    Answer: b

    Explanation: The statute defines a master plumber as someone who has worked as a journeyman for at least two years, or for at least one year after completing a training programme approved by the U.S. Department of Labor Office of Apprenticeship or another nationally recognised programme accepted by the Board.

    Source: Tex. Occ. Code §1301.002

  2. 2. Plumbing License Law and Board Rules

    A master license has been expired for two and a half years. Under §1301.403, to be licensed again the plumber must:

    • a.Pay twice the renewal fee for each year that was missed
    • b.Complete 12 hours of continuing education and pay one fee
    • c.Work for one year as a journeyman under another master
    • d.Meet the requirements for a new license, including examination

    Answer: d

    Explanation: A license expired for two years or more may not be renewed; the person must comply with the requirements and procedures, including examination, for an original license.

    Source: Tex. Occ. Code §1301.403

  3. 3. Plumbing Mathematics

    What is the internal cross-sectional area of a pipe with a 6-inch inside diameter? (Use 0.7854 × d².)

    • a.113 square inches
    • b.18.8 square inches
    • c.28.3 square inches
    • d.36.0 square inches

    Answer: c

    Explanation: Area = 0.7854 × 6 × 6 = 28.27 square inches. The figure 18.8 is the circumference, and 113 comes from using the diameter as the radius.

  4. 4. Plumbing Codes: Design and Commercial Systems

    A water distribution system is being sized. The water supply fixture unit is best described as:

    • a.A measure of the probable demand a fixture places on the supply
    • b.The pressure, in psi, required at the outlet of a fixture
    • c.The volume, in gallons, a fixture uses in a single operation
    • d.The actual flow, in gallons per minute, of a fixture's faucet or valve

    Answer: a

    Explanation: A water supply fixture unit expresses the probable hydraulic demand of a fixture, allowing for the chance that not all fixtures run at once. Totals are converted to gpm with a demand curve or table.

    Source: IPC §202; IPC Appendix E

  5. 5. Plumbing Codes: Design and Commercial Systems

    Under IPC §1108.2, a secondary roof drain system must discharge:

    • a.Through separate piping to a point above grade where occupants would normally see it
    • b.Into the vent stack that is nearest to the secondary roof drain
    • c.Into the primary storm conductor just below the level of the roof deck
    • d.Into the sanitary building drain through a trap and a backwater valve

    Answer: a

    Explanation: Secondary drains have separate piping and discharge above grade in a location normally observed by occupants or maintenance staff, so flow from them signals that the primary system is blocked.

    Source: IPC §1108.2

  6. 6. Plumbing Codes: Design and Commercial Systems

    In a multi-story building, vertical cast-iron drainage stacks must be supported, under IPC §308.5, at:

    • a.The base only, with a concrete pier under the lowest hub
    • b.The base and each floor, not exceeding 15 feet
    • c.The roof only, with a riser clamp
    • d.Every third floor, not exceeding 45 feet

    Answer: b

    Explanation: Vertical cast-iron pipe is supported at maximum intervals of 15 feet, which in practice means the base and each story; the base of the stack carries the weight during a water test.

    Source: IPC §308.5; §308.9

  7. 7. Water Heaters

    The terminal of a direct-vent water heater with an input of 60,000 Btu/h must, under IFGC §503.8, be located at least how far from any air opening into the building?

    • a.12 inches
    • b.36 inches
    • c.6 feet
    • d.10 feet

    Answer: a

    Explanation: Direct-vent terminal clearance from air openings is 6 inches for appliances up to 10,000 Btu/h, 9 inches up to 50,000 Btu/h and 12 inches above 50,000 Btu/h.

    Source: IFGC §503.8

  8. 8. OSHA Construction Safety

    A scaffold is erected near an uninsulated 7,200-volt power line. Under 1926.451(f)(6), the scaffold and any conductive material on it must stay at least:

    • a.10 feet from the line
    • b.50 feet from the line
    • c.1 foot from the line
    • d.3 feet from the line

    Answer: a

    Explanation: For uninsulated lines of less than 50 kV the minimum clearance is 10 feet, with more distance added above 50 kV. The 3-foot figure applies only to insulated lines under 300 volts.

    Source: 29 CFR 1926.451(f)(6)

  9. 9. Texas Accessibility Standards

    Under TAS §604.8.1.1, a wheelchair accessible toilet compartment with a wall-hung water closet must be at least:

    • a.72 inches wide and 96 inches deep
    • b.36 inches wide and 48 inches deep
    • c.60 inches wide and 56 inches deep
    • d.48 inches wide and 48 inches deep

    Answer: c

    Explanation: Wheelchair accessible compartments are 60 inches wide minimum and 56 inches deep minimum for wall-hung water closets, or 59 inches deep for floor-mounted water closets.

    Source: 2012 TAS §604.8.1.1

  10. 10. LP Gas

    LP-gas has an odorant added so that leaks can be smelled. The odorant commonly used is:

    • a.Hydrogen peroxide
    • b.Sodium chloride
    • c.Ethyl mercaptan
    • d.Carbon monoxide

    Answer: c

    Explanation: Propane is naturally odourless, so ethyl mercaptan is added to give the characteristic rotten-egg smell at concentrations well below the flammable limit.

    Source: NFPA 58, odorization