Texas Master Plumber Exam Practice Test
Sample practice questions
A few real questions from this free bank, with full explanations. Use the practice tool above for the whole set.
- 1. Plumbing License Law and Board Rules
Under Occupations Code §1301.002, a journeyman plumber with no apprenticeship programme behind them qualifies to sit for the master plumber exam after working as a journeyman for at least:
- a.Eight years
- b.Two years
- c.Six months
- d.Four years
Answer: b
Explanation: The statute defines a master plumber as someone who has worked as a journeyman for at least two years, or for at least one year after completing a training programme approved by the U.S. Department of Labor Office of Apprenticeship or another nationally recognised programme accepted by the Board.
Source: Tex. Occ. Code §1301.002
- 2. Plumbing License Law and Board Rules
A master license has been expired for two and a half years. Under §1301.403, to be licensed again the plumber must:
- a.Pay twice the renewal fee for each year that was missed
- b.Complete 12 hours of continuing education and pay one fee
- c.Work for one year as a journeyman under another master
- d.Meet the requirements for a new license, including examination
Answer: d
Explanation: A license expired for two years or more may not be renewed; the person must comply with the requirements and procedures, including examination, for an original license.
Source: Tex. Occ. Code §1301.403
- 3. Plumbing Mathematics
What is the internal cross-sectional area of a pipe with a 6-inch inside diameter? (Use 0.7854 × d².)
- a.113 square inches
- b.18.8 square inches
- c.28.3 square inches
- d.36.0 square inches
Answer: c
Explanation: Area = 0.7854 × 6 × 6 = 28.27 square inches. The figure 18.8 is the circumference, and 113 comes from using the diameter as the radius.
- 4. Plumbing Codes: Design and Commercial Systems
A water distribution system is being sized. The water supply fixture unit is best described as:
- a.A measure of the probable demand a fixture places on the supply
- b.The pressure, in psi, required at the outlet of a fixture
- c.The volume, in gallons, a fixture uses in a single operation
- d.The actual flow, in gallons per minute, of a fixture's faucet or valve
Answer: a
Explanation: A water supply fixture unit expresses the probable hydraulic demand of a fixture, allowing for the chance that not all fixtures run at once. Totals are converted to gpm with a demand curve or table.
Source: IPC §202; IPC Appendix E
- 5. Plumbing Codes: Design and Commercial Systems
Under IPC §1108.2, a secondary roof drain system must discharge:
- a.Through separate piping to a point above grade where occupants would normally see it
- b.Into the vent stack that is nearest to the secondary roof drain
- c.Into the primary storm conductor just below the level of the roof deck
- d.Into the sanitary building drain through a trap and a backwater valve
Answer: a
Explanation: Secondary drains have separate piping and discharge above grade in a location normally observed by occupants or maintenance staff, so flow from them signals that the primary system is blocked.
Source: IPC §1108.2
- 6. Plumbing Codes: Design and Commercial Systems
In a multi-story building, vertical cast-iron drainage stacks must be supported, under IPC §308.5, at:
- a.The base only, with a concrete pier under the lowest hub
- b.The base and each floor, not exceeding 15 feet
- c.The roof only, with a riser clamp
- d.Every third floor, not exceeding 45 feet
Answer: b
Explanation: Vertical cast-iron pipe is supported at maximum intervals of 15 feet, which in practice means the base and each story; the base of the stack carries the weight during a water test.
Source: IPC §308.5; §308.9
- 7. Water Heaters
The terminal of a direct-vent water heater with an input of 60,000 Btu/h must, under IFGC §503.8, be located at least how far from any air opening into the building?
- a.12 inches
- b.36 inches
- c.6 feet
- d.10 feet
Answer: a
Explanation: Direct-vent terminal clearance from air openings is 6 inches for appliances up to 10,000 Btu/h, 9 inches up to 50,000 Btu/h and 12 inches above 50,000 Btu/h.
Source: IFGC §503.8
- 8. OSHA Construction Safety
A scaffold is erected near an uninsulated 7,200-volt power line. Under 1926.451(f)(6), the scaffold and any conductive material on it must stay at least:
- a.10 feet from the line
- b.50 feet from the line
- c.1 foot from the line
- d.3 feet from the line
Answer: a
Explanation: For uninsulated lines of less than 50 kV the minimum clearance is 10 feet, with more distance added above 50 kV. The 3-foot figure applies only to insulated lines under 300 volts.
Source: 29 CFR 1926.451(f)(6)
- 9. Texas Accessibility Standards
Under TAS §604.8.1.1, a wheelchair accessible toilet compartment with a wall-hung water closet must be at least:
- a.72 inches wide and 96 inches deep
- b.36 inches wide and 48 inches deep
- c.60 inches wide and 56 inches deep
- d.48 inches wide and 48 inches deep
Answer: c
Explanation: Wheelchair accessible compartments are 60 inches wide minimum and 56 inches deep minimum for wall-hung water closets, or 59 inches deep for floor-mounted water closets.
Source: 2012 TAS §604.8.1.1
- 10. LP Gas
LP-gas has an odorant added so that leaks can be smelled. The odorant commonly used is:
- a.Hydrogen peroxide
- b.Sodium chloride
- c.Ethyl mercaptan
- d.Carbon monoxide
Answer: c
Explanation: Propane is naturally odourless, so ethyl mercaptan is added to give the characteristic rotten-egg smell at concentrations well below the flammable limit.
Source: NFPA 58, odorization