Chapter 2 of 7

General Requirements and Fixtures

These questions follow the plumbing chapters of the 2018 International Residential Code: chapter 25 (administration and testing), chapter 26 (general requirements) and chapter 27 (fixtures). Section numbers are given so you can find the rule in the code book your city has adopted.

Protecting pipe and structure

Pipe is supported, protected from damage and installed without weakening the framing. Where pipe passes close to the face of a stud or joist, steel shield plates protect it from nails and screws.

Shield plates
Required where piping is close to the face of framing; see the section for the distance.
IRC §P2603.2.1
Bedding
Buried pipe rests on a firm, continuous bed for its full length.
IRC §P2604.1
Support
Spacing depends on the pipe material.
IRC Table P2605.1

Testing and inspection

Rough plumbing is tested before it is covered. The drain, waste and vent system is tested with water or air, and the water supply at working pressure or higher.

DWV test
Water or air test at rough-in.
IRC §P2503.5
Water supply test
At not less than working pressure.
IRC §P2503.7

Fixtures

Fixtures are set level, with enough clearance to use and clean them, and with access to concealed slip joints. Showers and tub-shower valves limit the outlet temperature to prevent scalding.

Water closet clearances
Side and front clearances are set by the fixture section.
IRC §P2705.1
Shower valves
Pressure-balance or thermostatic valves with a temperature limit.
IRC §P2708.4
Floor drains
Outlet at least 2 inches, with a removable strainer.
IRC §P2719.1