Load & DesignPregunta 14 de 110

If a home has a calculated cooling load of 30,000 BTU/hr, what nominal equipment size is the closest match?

a.2 tons
b.2.5 tons
c.3.5 tons
d.4 tons

Explicación

30,000 BTU/hr divided by 12,000 BTU/hr per ton equals 2.5 tons. Manual S guides selecting a unit whose capacity at design conditions closely matches this load. Choosing 2.5 tons avoids the humidity and cycling problems of oversizing.

Practica las 110 preguntas gratis — sin registro.

Preguntas relacionadas de este tema

Última revisión: · proceso editorial

Equipo Editorial de PrepPass · Verificado con California CSLB C-20 Warm-Air HVAC Trade Exam · Cómo revisamos