InstallationPregunta 34 de 110
In a split-system heat pump, the outdoor coil functions as the condenser during which mode?
a.Heating mode
b.Defrost mode
c.Cooling mode
d.Emergency heat mode
Explicación
In cooling mode the outdoor coil rejects heat and acts as the condenser, while the indoor coil absorbs heat as the evaporator. In heating mode the reversing valve swaps these roles. Understanding this reversal is key to installing and servicing heat pumps.
Practica las 110 preguntas gratis — sin registro.
Preguntas relacionadas de este tema
- What is the purpose of maintaining manufacturer-specified clearances to combustibles around a furnace?
- A properly installed refrigerant line set should have the liquid line and suction line sized according to what?
- On a long vertical suction riser, what feature helps ensure compressor oil returns properly?
- What is the function of the reversing valve in a heat pump?
- A package unit differs from a split system in what way?
- Gas piping for a furnace must be sized primarily to do what?
Última revisión: · proceso editorial
Equipo Editorial de PrepPass · Verificado con California CSLB C-20 Warm-Air HVAC Trade Exam · Cómo revisamos