Fixtures & Water Heaters

A clothes-washer standpipe trap must be located at what height above the floor?

  • a.At the ceiling
  • b.48 in above the floor
  • c.Below the floor
  • d.6 in to 18 in above the floor✓

The standpipe trap must be set between 6 in and 18 in above the floor (IPC 802.4), keeping the seal accessible and at a workable height while the standpipe rises above it. Below the floor or at the ceiling is outside the allowed range.

Fixtures & Water Heaters

The floor of a shower compartment must slope to the drain at a minimum of:

  • a.1/4 in per ft✓
  • b.1/8 in per ft
  • c.1 in per ft
  • d.1/2 in per ft

A shower floor must slope to the drain at not less than 1/4 in per ft (about 2 percent) so water does not stand (UPC 408.5 / IPC 417.5.2). 1/8 in per ft is too flat and 1/2 in or 1 in per ft is steeper than required and awkward to stand on.

Fixtures & Water Heaters

A model-code showerhead is limited to 2.5 gpm at 80 psi. Where several showerheads serve one shower compartment, many codes limit the flow to:

  • a.1.5 gpm
  • b.2.5 gpm combined for the compartment✓
  • c.2.0 gpm
  • d.5.0 gpm

The model-code maximum is 2.5 gpm per showerhead at 80 psi, and many adopted codes limit the combined flow of all heads serving one compartment to 2.5 gpm as well, so confirm the adopted code. Treating each head as a separate 2.5 gpm allowance can exceed the limit.

Fixtures & Water Heaters

What is the minimum drain size for a commercial food-waste grinder (disposer)?

  • a.2 in✓
  • b.1-1/4 in
  • c.1-1/2 in
  • d.3 in

A commercial food-waste grinder requires a minimum 2 in drain and trap because of the volume and character of its discharge (IPC 704 / manufacturer listing). 1-1/2 in serves a residential disposer, and 1-1/4 in is far too small.

Fixtures & Water Heaters

What is the minimum drain size for a residential food-waste grinder (disposer)?

  • a.1-1/2 in✓
  • b.3 in
  • c.2 in
  • d.1-1/4 in

A residential disposer discharges through the kitchen-sink drain and requires a minimum 1-1/2 in drain and trap. 1-1/4 in is the lavatory minimum and is undersized for a disposer, while 2 in is the commercial-grinder minimum.

Fixtures & Water Heaters

What is the minimum trap and drain size for a bathtub?

  • a.3 in
  • b.1-1/4 in
  • c.2 in
  • d.1-1/2 in✓

A bathtub requires a minimum 1-1/2 in trap and drain (IPC Table 709.1). 1-1/4 in is the lavatory minimum and is undersized for a tub, and 2 in or 3 in exceeds what a tub requires.

Fixtures & Water Heaters

An emergency eyewash or drench shower for worker safety must deliver tepid water in what temperature range?

  • a.32 to 50 degrees F
  • b.About 140 degrees F
  • c.110 to 120 degrees F
  • d.60 to 100 degrees F✓

Emergency eyewash and shower equipment must deliver tepid flushing fluid, generally 60 to 100 degrees F (ANSI/ISEA Z358.1), so a victim can tolerate a full flush without cold shock or scalding. 110 degrees and above is a scald risk and near-freezing water drives victims off the unit.

Fixtures & Water Heaters

A bathtub trap and its waste-and-overflow concealed in a wall or floor must be provided with:

  • a.No access, since it is concealed
  • b.A wall that is cut open each time service is needed
  • c.The overflow opening only
  • d.An access panel or other approved access to the trap and waste✓

Concealed slip-joint connections such as a tub waste-and-overflow must remain accessible through an access panel or removable access so the joints can be serviced (IPC 405.8 / 712 access rules). Sealing them permanently behind finished construction is not permitted.

Fixtures & Water Heaters

To control Legionella growth, stored hot water in a water heater is generally kept at a minimum of about:

  • a.110 degrees F
  • b.90 degrees F
  • c.180 degrees F
  • d.140 degrees F✓

Storing water at about 140 degrees F suppresses Legionella, while the water delivered to fixtures is tempered down (for example to 110 degrees F at public lavatories) with a mixing valve to prevent scalding. 90 and 110 degrees are within the range where the bacteria thrive.

Fixtures & Water Heaters

A fuel-fired water heater installed in a bathroom or a bedroom must be:

  • a.Any atmospheric-vented type
  • b.Prohibited entirely
  • c.Limited to an electric water heater only, because no gas-fired unit of any kind may ever be placed in a bedroom or bathroom
  • d.A direct-vent or sealed-combustion type, or installed in a sealed enclosure with combustion air from outdoors✓

A fuel-burning water heater in a bedroom or bathroom must be a direct-vent unit or be enclosed in a sealed room that draws combustion air from outdoors, so occupants are not exposed to combustion products in a sleeping or bathing space (IFGC / IRC). An open atmospheric unit is not allowed there.

¿Qué tan difícil es el examen?

La licencia de plomero oficial la administra cada estado (basada en el UPC o el IPC), así que el formato varía por estado. En Texas, por ejemplo, es un examen escrito a libro cerrado de 100 preguntas en 120 minutos más una práctica manual, cada uno requiere 70% para aprobar, con tarifas de unos $68.50 (escrito) y $40 (práctico). Los plomeros, instaladores de tubería y de vapor ganan una mediana de unos $62,970 al año (BLS, mayo 2024).

Horas de estudio recomendadas
60-120 horas para la mayoría — búsqueda de código, dimensionamiento de tubería por unidades de mueble, ventilación y tubería de gas.
Tasa de aprobación publicada
72,30% en todos los exámenes que TSBPE administró en el año fiscal 2025 (7.075 personas examinadas), y es la única cifra que publica. TSBPE no desglosa por tipo de licencia, así que no hay un número específico de journeyman; su propia metodología dice que “quienes rinden el examen varias veces se cuentan cada vez”, lo que la hace explícitamente una tasa de todos los intentos. La licencia de plomería es estatal, así que esto es solo Texas.Fuente: TSBPE — Legislative Appropriations Request FY2028-2029 (PDF), “Pass Rate”, Exp 2025 · TSBPE — Strategic Plan FY2027-2031 (PDF), definition and methodology of “Examination Pass Rate”
Por dónde empezar
Drenaje, desagüe y ventilación, más suministro de agua y tubería de gas — los capítulos centrales del código, aunque los estados rara vez publican pesos porcentuales exactos.

Las tarifas y los salarios son aproximados y cambian con el tiempo. La tasa de aprobación de arriba se cita de la fuente enlazada junto a ella, para el periodo que esa fuente cubre; cuando no hemos verificado una fuente, lo decimos y no damos ninguna cifra.

Reportar