Water Supply & DistributionPregunta 58 de 120
Using velocity (fps) = 0.408 x flow (gpm) divided by the square of the inside diameter (in), what is the velocity of 12 gpm flowing in 3/4 in Type L copper with an inside diameter of 0.785 in?
a.About 4.4 fps
b.About 6.0 fps
c.About 7.9 fps
d.About 10.2 fps
Explicación
0.408 x 12 = 4.896, and 0.785 squared is 0.616, so 4.896 / 0.616 = 7.9 fps, right at the practical 8 fps cold water limit. The 4.4 and 6.0 answers come from dividing by the diameter instead of the diameter squared or from using the nominal 3/4 in size. The 10.2 answer uses a smaller inside diameter such as 0.69 in, which belongs to a heavier wall tube.
Practica las 120 preguntas gratis — sin registro.
Preguntas relacionadas de este tema
- A dwelling unit contains one flush tank water closet (2.5 WSFU), two lavatories (1.0 WSFU each), one bathtub with shower (4.0 WSFU), one kitchen sink (1.5 WSFU), one dishwasher (1.5 WSFU), and one clothes washer (4.0 WSFU). What is the total water supply fixture unit load?
- Using the standard fixture unit to gpm conversion curve, what happens to the estimated demand when the total water supply fixture unit load on a system is doubled?
- What is the minimum nominal size normally permitted for a water service pipe serving a building?
- The highest fixture in a building is 28 ft above the meter and requires 15 psi residual. Meter loss is 5 psi and calculated friction loss in the piping is 12 psi. What minimum static pressure is needed at the meter?
- A 60 ft straight run of CPVC hot water pipe will see a 70 degree F temperature change. Using a coefficient of thermal expansion of 0.000034 in per in per degree F, approximately how much will the run expand?
- An existing galvanized steel water line is being extended with copper tube. What must be installed at the point where the two materials join?
Última revisión: · proceso editorial
Equipo Editorial de PrepPass · Verificado con Journeyman Plumber Licensing Exam (UPC/IPC-based) · Cómo revisamos