Water Supply & DistributionPregunta 59 de 120

A 60 ft straight run of CPVC hot water pipe will see a 70 degree F temperature change. Using a coefficient of thermal expansion of 0.000034 in per in per degree F, approximately how much will the run expand?

a.About 0.6 in
b.About 1.0 in
c.About 2.4 in
d.About 1.7 in

Explicación

Convert to inches first: 60 ft = 720 in, and 720 x 0.000034 x 70 = 1.71 in of movement, which is why an offset or expansion loop is needed. The 0.6 in and 1.0 in answers come from using only part of the temperature change or forgetting the foot-to-inch conversion. The 2.4 in answer uses a temperature change near 100 degrees F rather than the 70 degrees stated.

Practica las 120 preguntas gratis — sin registro.

Preguntas relacionadas de este tema

Última revisión: · proceso editorial

Equipo Editorial de PrepPass · Verificado con Journeyman Plumber Licensing Exam (UPC/IPC-based) · Cómo revisamos