Fixtures & Water HeatersPregunta 75 de 120

An indirect waste pipe from a commercial ice machine is 1-1/2 inches in diameter and discharges into a floor sink. What is the minimum required air gap?

a.1 inch
b.2 inches
c.3 inches
d.1-1/2 inches

Explicación

The air gap for an indirect waste must be at least twice the effective diameter of the discharge pipe, so 2 times 1-1/2 inches equals 3 inches measured from the pipe outlet to the flood level rim of the receptor. 1 inch is only the absolute minimum air gap for very small pipes. 2 inches and 1-1/2 inches apply the wrong multiplier to the pipe size.

Referencia Legal: IPC §802.2

Practica las 120 preguntas gratis — sin registro.

Preguntas relacionadas de este tema

Última revisión: · proceso editorial

Equipo Editorial de PrepPass · Verificado con Journeyman Plumber Licensing Exam (UPC/IPC-based) · Cómo revisamos
Reportar