SafetyPregunta 107 de 110
Cutting and grinding cast iron or concrete for a plumbing penetration generates respirable crystalline silica. What is the primary control the plumber should use?
a.Work faster
b.Open a window only
c.Wet cutting or on-tool dust collection (engineering controls) plus respiratory protection as needed
d.No control is needed for short tasks
Explicación
The primary defense against respirable silica is engineering controls, using water (wet cutting) or a vacuum dust-collection shroud on the tool to suppress dust at the source, supplemented by respiratory protection when needed. Silica dust causes silicosis and is regulated with a strict exposure limit. Dry cutting without controls quickly exceeds the permissible exposure limit.
Referencia Legal: 29 CFR 1926.55Practica las 110 preguntas gratis — sin registro.
Preguntas relacionadas de este tema
- A 2,000 lb cast-iron section is lifted by a two-leg sling with each leg at 60 degrees from horizontal. Each leg carries (load / 2) / sin(60 degrees), with sin(60) about 0.866. What is the tension in each sling leg?
- During sewer confined-space work, the attendant outside must maintain what capability?
- A trench 10 ft deep in Type B soil is sloped at 1 to 1 (horizontal to vertical) on both sides. If the trench bottom is 3 ft wide, how wide is the excavation at the top?
- A trench 90 ft long and 6 ft deep requires egress so no worker travels more than 25 ft laterally to a ladder. A ladder placed mid-run protects 25 ft in each direction, or 50 ft total. What is the minimum number of ladders required?
- Before servicing a sewage ejector pump, the plumber must control hazardous energy. What procedure prevents the pump from starting during service?
- On a California jobsite, a trench 5 ft or deeper in which workers will enter also requires a specific state permit beyond federal rules. What is that requirement?
Última revisión: · proceso editorial
Equipo Editorial de PrepPass · Verificado con Master Plumber Licensing Exam (UPC/IPC-based) · Cómo revisamos