Texas Master Electrician Exam — Open-Book Study Guide (2026 NEC) cover

Sách ôn thi · Ấn bản 2026

Texas Master Electrician Exam — Open-Book Study Guide (2026 NEC)

For the TDLR Master Electrician exam PSI gives in two open-book portions.

Phiên bản: Written to the 2026 NEC and PSI's bulletin updated 9/15/2026: two open-book portions, 70% on each.

Độ dài
271 trang
Câu hỏi luyện tập trong sách
409
Thi thử trực tuyến PrepPass
108 câu · 320 phút
Đối chiếu thông tin và cập nhật tệp
tháng 11 năm 2026
Giao hàng
PDF + EPUB · tiếng Anh · tải ngay

Vui lòng đọc trước khi mua: An independent study guide, not affiliated with or endorsed by the National Fire Protection Association (NFPA), the Texas Department of Licensing and Regulation (TDLR) or PSI.

Đọc phần còn lại của thông báo

It cites NEC section and table numbers so you can find each rule in your own Code book; it does not reproduce Code text or tables and does not replace the Code book. Every practice question is original, not a real or recalled exam item. NEC, NFPA 70 and National Electrical Code are registered trademarks of the NFPA.

Về cuốn sách này

For the TDLR Master Electrician exam PSI gives in two open-book portions: how to set up your own 2026 NEC, where to open it for each kind of question, the calculation steps in order, and two full timed practice portions.

Lệ phí thi, cả hai phần: $78 mỗi lần thi, nộp cho PSI. Thi lại phải nộp lại. Cuốn sách này: $14.99, trả một lần.

Thông tin kỳ thi, ai nên dùng và thay đổi

Xem bên trong cuốn sách

Ba trang thật, kết xuất thẳng từ tệp PDF bạn sẽ tải — lần lượt là một trang tra cứu, một trang giảng giải, và một câu hỏi có lời giải. Không trang nào được vẽ lại cho đẹp.

  • Cách giảng dạy
    Part 4. Find-it drills · Trang 146 của PDF
  • Cách giảng dạy
    Part 5. Two full practice portions · Trang 185 của PDF
  • Một câu hỏi có lời giải
    Chapter 2. Services, Service Equipment and Separately Derived Systems · Trang 67 của PDF

Thi trong vòng hai tuần?

Sách này là phần giảng dạy, đọc trong nhiều tuần. Nếu bạn thi trong vòng hai tuần, tập ôn in được mới là sản phẩm phù hợp: mọi con số gộp theo giá trị, mặt tự viết lại, và lộ trình cho 14 ngày, 7, 3 hoặc tối nay.

Xem tập ôn — $9.99 →

47 trang · US Letter · PDF in được · giữ vĩnh viễn

Có gì — và không có gì

Bao gồm

  • PSI's published content outline on one page: the scored items per content area for both portions (bulletin updated September 15, 2026)
  • A 20-question diagnostic, two questions from each of PSI's ten content areas, to tell you which areas to study first

Không bao gồm

  • Không gửi bản in — đây là tệp bạn tải về và có thể tự in
  • Sách không kèm khoá video, giảng viên hay kèm riêng — video miễn phí trên trang là phần khác
Toàn bộ phần bao gồm và không bao gồm

Bao gồm

  • Setting up your own 2026 NEC: the tabs and markings PSI allows, what moved in the 2026 edition, and a clock plan for each portion
  • A finder table for each of the ten content areas: from the kind of question to the section or table to open
  • Ten chapters in PSI's content areas, each ending with a short check, 40 questions in all
  • 26 timed find-it drills, each answered with the section to open first
  • Two full practice portions sized to PSI's scored items: 70 NEC Knowledge questions in 150 minutes and 30 Calculations questions in 170 minutes, every answer explained
  • A question-bank appendix: 223 more questions in PSI's ten content areas, with answers and explanations, for 409 practice questions in the book
  • Formula pages, a seven-day final plan and an A to Z index from key word to Code section
  • Reads alongside your own 2026 NEC: section and table numbers with explanations in our own words, no Code text
  • PDF (print it) + EPUB (phone / e-reader)

Không bao gồm

  • Không bao gồm lệ phí đăng ký thi hay phí trung tâm khảo thí — bạn vẫn nộp cho cơ quan chính thức

Mục lục

Xem 14 phần và trang bắt đầu của từng phần
  1. Part 1. Your Code book is the tooltr. 14
  2. Part 2. Finder: from the question to the pagetr. 31
  3. Part 3. The ten content areastr. 60
  4. Chapter 1. Definitions, Theory and Planstr. 60
  5. Chapter 2. Services, Service Equipment and Separately Derived Systemstr. 67
  6. Chapter 4. Branch-Circuit Design: Ampacity, Terminations and Protectiontr. 83
  7. Chapter 5. Wiring Methods and Materialstr. 91
  8. Chapter 6. Electrical Equipment and Devicestr. 98
  9. Chapter 7. Motors, Compressors and Generators: Designing the Complete Circuittr. 106
  10. Chapter 8. Control Devices and Disconnectingtr. 114
  11. Chapter 9. Special Occupancies, Equipment and Conditionstr. 122
  12. Chapter 10. Renewable Energy Technologies: Photovoltaics and EV Chargerstr. 131
  13. Part 4. Find-it drillstr. 140
  14. Part 5. Two full practice portionstr. 150

Lấy từ chính tệp PDF bạn tải về, kèm trang bắt đầu của từng phần — không phải gõ tay ở đây.

Đọc miễn phí trọn một chương

Trọn vẹn một chương, đúng như trong eBook. Cuộn cửa sổ để đọc ngay tại đây; không cần tải, không cần email.

Đọc chương 1 ngay tại đây, không rời trang

The free part is Part 1: the Code book PSI lets into the room, how to mark it up before exam day, what moved in the 2026 edition, working the clock and the formula pages.

ĐỌC THỬ MIỄN PHÍ — NGAY TẠI ĐÂY
Chương 1 · ≈13 phút đọc
Part 1. Your Code book is the tool
cuộn ↓

The exam is open book. The Code book answers every Code question on the exam, but only if you reach the right page in time. This part is about that: a book that is legal to bring, marked so your eye lands on the right line, and a way of working the clock.

1.1 A book PSI will let into the room

PSI's bulletin (updated September 15, 2026) sets these rules for the Code book you bring:

AllowedNot allowed
Any soft-bound edition of the NEC (questions follow the 2026 edition)Loose-leaf, spiral-bound or ring-bound copies
Highlighting, underlining and notes made before the exam sessionWriting, highlighting, underlining or marking the book during the session
Permanent index tabs made or supplied by the NEC book's publisherHomemade, DIY or other non-NEC tabs
A non-programmable, silent, battery calculator with no alphabet keyboard and no paper tapeAny added paper: loose, taped, stapled or stuck in
The NEC Handbook

PSI provides an electronic notepad. A candidate who arrives with a book that breaks these rules is offered three choices: test without the book, remove the non-compliant tabs, or forfeit the fee and test another day.

Two practical points follow. First, do all of your marking at home; the pen and highlighter stay outside. Second, check your tabs: if they did not come from the Code book's publisher, take them off before exam day.

1.2 Mark it up before exam day

Highlighting and notes are allowed as long as they are in the book before the session starts. Use that. A marked book turns a search into a glance.

A workable system:

  1. One colour for numbers you will be asked for (a distance, a percentage, an ampere rating). Highlight the number and the two or three words that say what it applies to.
  2. A second colour for the words that flip an answer: "not less than", "not more than", "continuous", "dwelling", "other than".
  3. Mark exceptions as exceptions. PSI says not to use an exception unless the question tells you to. Bracket each one in the margin so you do not read it as the main rule under time pressure.
  4. Write the next stop in the margin. Where a calculation sends you from one section to a table, write the table number beside the section. Chapter by chapter, this book gives you those chains.
  5. Write on the table pages which column to use. For ampacity questions the terminal temperature rating picks the column; note that beside the table heading.

Tabs

PSI's bulletin allows permanent index tabs manufactured or provided by the publisher of your Code book, and bars homemade, DIY and non-NEC tabs. A set from any other maker is not on the allowed list: do not put it on. A candidate who arrives with such tabs has to remove them, test without the book, or forfeit the fee and come back another day.

Putting a tab set on well takes about an hour:

  1. Check every tab against the 2026 contents first. A set printed for an earlier edition carries article numbers that have moved (see section 1.3).
  2. Start at the back of the book and work forward, so the tabs already placed never hide the page you are looking for.
  3. Put each tab on the right-hand page where its article or table begins, and step the tabs down the edge in rows so that no tab covers another.
  4. Press each tab down firmly. The bulletin's word for the tabs it allows is permanent, and it bars any added paper, loose or attached.
  5. If you have more tabs than patience, place these first: Article 100, Article 110, Article 120, Article 215, Article 230, Article 240, Article 250, Article 310, Article 430, Article 450, Article 500, Article 501, Article 690, Article 700. They are the articles this book sends you to most often.

Tabs get you to the article. Your highlighting gets you to the line. You need both.

The list below is where to start. These are the 40 places in the 2026 Code that this book's chapters and practice bank point to most often. That is a measure of this book, taken from its own pages; it does not predict what PSI will ask.

Open toWhat to mark there
Article 100Demand factor
§110.14Lowest rating governs; 100 amperes or less; Over 100 amperes
§110.16Arc-flash label and marking
§110.26Width; Headroom; Entrance at each end for large equipment; Personnel doors
Table 110.26(A)(1)Depth
§120.41Dwelling general lighting
Table 120.45Lighting demand factors
Table 120.47Receptacle demand
§120.53Fastened-in-place appliances
Table 120.54Dryer demand
Table 120.55Range demand and its notes
Table 120.56Commercial kitchen equipment
§120.61Neutral reduction; Range neutral; Neutral above 200 amperes
§120.82Optional dwelling general loads; Optional heating and cooling
§215.4Conductor ampacity; Minimum grounded conductor
§230.42Continuous load test; After-correction test
§230.95GFPE setting and delay; GFPE testing
§240.4Next standard size; Small conductors
§240.2110-foot tap; 25-foot tap; Transformer tap secondary; 10-ft secondary conductors
§250.28Main bonding jumper; Green bonding screw
§250.30Supply-side bonding jumper; Derived system GEC; Common GEC
Table 250.66GEC table
§250.66Rod, pipe or plate cap; Concrete-encased cap
Table 250.122Equipment grounding conductor
§310.15Rooftop adder; Correction and adjustment together; Nonlinear neutral
§430.22Single motor; Dc motor on a rectifier; Wye-start, delta-run
§430.24Motor feeder conductors
§430.32Separate overload; Integral protector
Table 430.52(C)(1)Table percentages
§430.62Motor feeder protection
§430.109Manual motor controller; Small stationary motors; Very large motors
§430.110Single motor; Combination load; Small motor locked-rotor current
Table 450.5(B)125 percent limit
§500.5Ammonia room; Metal dust
§500.6Gas groups by safe gap
§501.15Seal at enclosures; Boundary seal
§690.8125 percent method; Engineered method floor; Common-return conductor; Strings on one device
§690.9Device rating; Protection at one end; Device access
§690.12Voltage after shutdown; Multiple systems; Label lettering
§700.12Restoration time; Battery performance

1.3 What moved in the 2026 edition

If you trained on an earlier edition, or your notes and tabs came from one, these are the moves to know before you mark your book. Each was confirmed on the 2026 page.

If your old notes sayIn the 2026 Code look in
Article 220, load calculationsArticle 120
Table 300.5, burial coverTable 300.7(A)
215.2, feeder conductor rating and size215.4
215.3, feeder overcurrent protection215.5
"In Sight From" in Article 100110.29
450.3 and its tables, transformer overcurrent protection450.5 and Tables 450.5(A) and 450.5(B)

The load-calculation move is the big one: every section you knew as 220.xx is now in Article 120, and a 2023 tab set will send you to the wrong place.

1.4 Working the clock

The Knowledge portion gives you 75 items in 150 minutes, about 2.0 minutes each. The Calculations portion gives you 33 items in 170 minutes, about 5.2 minutes each. One question shows at a time, the minutes remaining show at the top of the screen, and PSI's bulletin says you can go back to any question and change your answer while time remains.

That makes a two-pass method possible:

  1. First pass: answer what you can find quickly. Read the question, pick out the key word, go to the article, answer. If you have not found the rule in about the average time per item, enter your best choice, note the question number on the electronic notepad and move on.
  2. Second pass: return to your noted questions with the time you saved. A long search on one item now costs you nothing else.
  3. Last five minutes: make sure nothing is blank.

Three reading habits prevent most wrong answers:

  • Find the condition before the number. "Continuous", "dwelling unit", "75 degree C terminals", "aluminum", "more than three current-carrying conductors": each of these changes the table, the column or the multiplier.
  • Main rule unless told otherwise. No exceptions and no optional calculation method unless the question names one.
  • Copper unless told otherwise.

And one for the calculation portion: write every step on the notepad in the order the chapter gives it. A skipped step can still produce a number that matches an option, so a match is not proof that it is right.

1.5 Formula pages

The only reference PSI's bulletin lists for the exam room is your Code book, and it bars any added paper. Notes written in the book before the session are allowed, so the formulas you want at hand can be written on the pages where you will use them, at home, ahead of time.

Circuit formulas (not in the Code; know them cold)

To findFormula
Voltage, current, resistanceE = I x R; I = E / R; R = E / I
Power, single-phase or dcP = E x I; P = I x I x R; P = (E x E) / R
Power, three-phaseP = 1.732 x E x I x power factor
Current from volt-amperes, single-phaseI = VA / E
Current from volt-amperes, three-phaseI = VA / (1.732 x E)
Horsepower to watts1 hp = 746 W
Efficiencyoutput / input
Percent voltage drop(volts dropped / circuit voltage) x 100

Voltage drop and fault current

To findFormulaOpen to
Voltage drop, single-phaseVD = (2 x K x I x L) / circular mils. L is the one-way length in feet; this book's worked examples use K = 12.9 for copperChapter 9, Table 8 for the circular-mil area
Voltage drop, three-phaseVD = (1.732 x K x I x L) / circular milsChapter 9, Table 8
Smallest conductor for a voltage-drop limitcircular mils = (2 x K x I x L) / volts allowed, then the first size in the table with at least that areaChapter 9, Table 8
Transformer full-load currentVA / E single-phase; VA / (1.732 x E) three-phase
Available fault current at transformer terminals (estimate)full-load current / impedance as a decimal (2% is 0.02)

Code calculations: the rule, in our words, and where to read it

Each row is a reminder of a rule this book teaches. Read the Code text at the place named before you rely on it, and write the next stop in the margin there.

Load calculations

Step or ruleWhat to doOpen to
Dwelling general lightingCalculated at 2 VA per sq ft before demand factors.§120.41
Show windows200 VA per linear foot.§120.46(A)
Small-appliance and laundry circuitsEach is included at 1,500 VA.§120.52
Fastened-in-place appliancesFour or more on the same dwelling feeder may be taken at 75 percent.§120.53
Dryer loadNameplate rating or 5,000 VA, whichever is larger.§120.54
Neutral reductionTwo 70 percent reductions are permitted: the range, wall-oven, cooking-unit and dryer portion under (B)(1), and the part of the unbalanced load above 200 amperes under (B)(2).§120.61(B)
Neutral above 200 amperesThe portion over 200 amperes may be taken at 70 percent.§120.61(B)(2)
Range neutralThe neutral load for household ranges may be taken at 70 percent of the range demand.§120.61(B)(1)
Optional dwelling methodFirst 8 kVA of general load at 100 percent and the remainder at 40 percent.§120.82(B)
Central space heatingCentral systems: heat pump compressor at 100 percent plus 65 percent of the supplemental electric heating; 65 percent also for fewer than four separately controlled units.§120.82(C)
Multifamily optional methodLimited to buildings with three or more dwelling units that meet the stated conditions.§120.84

Continuous loads: branch circuits, feeders, services

Step or ruleWhat to doOpen to
Voltage-drop guidance3 percent for the branch circuit and 5 percent overall are recommendations only.§210.19 Informational Note
Continuous loadDevice rating is at least the noncontinuous load plus 125 percent of the continuous load.§210.20(A)
Conductor ampacityAt least 125 percent of the continuous load plus the noncontinuous load.§215.4(A)(1)
Minimum grounded conductorNot smaller than the equipment grounding conductor required for the feeder.§215.4(B)
Device ratingAt least 125 percent of the continuous load plus the noncontinuous load, rounded up to a standard size.§215.5
Continuous load testAmpacity of at least the noncontinuous load plus 125 percent of the continuous load.§230.42(A)(1)
After-correction testAmpacity remaining after adjustment and correction must be at least the maximum load served.§230.42(A)(2)

Ampacity, adjustment and correction

Step or ruleWhat to doOpen to
Terminations over 100 amperesHigher-rated conductors are used at their 75 degrees C ampacity unless the equipment is listed and identified otherwise.§110.14(C)(1)
Lowest rating governsAmpacity at a termination is based on the lowest temperature rating of any connected termination, conductor or device.§110.14(C)
100 amperes or lessUse the 60 degree C ampacity unless the equipment is listed and identified for higher.§110.14(C)(1)(a)
Over 100 amperesUse the 75 degree C ampacity unless the equipment is listed and identified for higher.§110.14(C)(1)(b)
TorqueTerminations with a marked torque are tightened to that value by an approved means.§110.14(D)
Ambient correctionMultiply the table ampacity by the factor for the ambient range, such as 0.82 for 46 to 50 degrees C on a 90 degree C conductor.Table 310.15(B)(1)(1)
Conductor-count adjustment80 percent for 4 to 6, 70 percent for 7 to 9, 50 percent for 10 to 20 current-carrying conductors.Table 310.15(C)(1)
Both factors togetherWhere both conditions exist, apply both factors to the insulation-column ampacity.§310.15
Nonlinear neutralThe neutral of a 4-wire wye circuit with mostly nonlinear load counts as current-carrying.§310.15(E)
Rooftop adderA sunlit raceway less than 3/4 inch above a roof takes 33°C added to the outdoor temperature before correction.§310.15(B)(2)

Grounding and bonding sizes

Step or ruleWhat to doOpen to
GEC tableSized by the ungrounded service conductors, for example 2/0 copper for over 600 through 1,100 kcmil.Table 250.66
Rod, pipe or plate capThe conductor to these electrodes alone need not exceed 6 AWG copper.§250.66(A)
Concrete-encased capThe conductor to this electrode alone need not exceed 4 AWG copper.§250.66(B)
Equipment grounding conductorSize from the rating of the feeder overcurrent device.Table 250.122

Box fill and raceway fill

Step or ruleWhat to doOpen to
Volume allowancesEach conductor is counted at the cubic-inch allowance for its own size.Table 314.16(B)(4)
Internal clampsInternal cable clamps add one allowance based on the largest conductor in the box.§314.16(B)(2)
Nipple fillA nipple 24 inches or shorter between enclosures may be filled to 60 percent of its total area.Chapter 9, Notes to Tables, Note 4
RoundingFor same-size conductors, the count goes up to the next whole number only at a decimal of 0.8 or larger.Chapter 9, Notes to Tables, Note 7
Fill limitMore than two conductors may occupy no more than 40 percent of the raceway area.Chapter 9, Table 1
Mixed sizesAdd the individual conductor areas, grounding conductor included, and compare the sum with the raceway's 40 percent area.Chapter 9, Table 4

Motors and air-conditioning equipment

Step or ruleWhat to doOpen to
General motorsTable full-load current sizes the conductors and short-circuit protection, and nameplate current sizes separate overloads.§430.6(A)(1)
Torque motorsThe nameplate locked-rotor current is the rated current for sizing branch-circuit conductors.§430.6(B)
Single motorBranch-circuit conductors carry at least 125 percent of the table full-load current.§430.22
Dc motor on a rectifierConductors from a single-phase full-wave rectifier are sized at 150 percent, and half-wave at 190 percent.§430.22(A)
Wye-start, delta-runConductors between the controller and the motor are sized at 72 percent of full-load current.§430.22(C)
Duty-cycle serviceIntermittent duty with a 15-minute rated motor uses 85 percent of nameplate current.Table 430.22(E)
Largest motorTaken at 125 percent, so 25 percent of its full-load current is added.§430.24
Separate overload125 percent of nameplate with a 1.15 service factor or a 40 degree C rise marking, 115 percent for all other motors.§430.32(A)(1)
Integral protector170, 156 or 140 percent of table full-load current depending on the size of that current.§430.32(A)(2)
Overload unitsA three-phase ac motor needs three overload units, one in each phase.Table 430.37
Table percentagesSquirrel-cage motors: 175 percent dual-element fuse, 250 percent inverse-time breaker, 300 percent non-time-delay fuse.Table 430.52(C)(1)
Starting ceilingWhen the table value will not start the motor, an inverse-time breaker may be raised to no more than 400 percent of full-load current of 100 A or less, or 300 percent above 100 A; the ceiling is not rounded up.§430.52(C)(1)
Motor feeder protectionNot more than the largest motor branch device plus the other full-load currents; choose the standard size at or below that sum.§430.62(A)
Three-phase table valuesAt 460 volts the table lists 34 A for 25 hp and 65 A for 50 hp.Table 430.250
Compressor protectionThe device starts at 175 percent of rated-load current, and rounding up depends on an exception.§440.22(A)
Single compressor conductorsAt least 125 percent of the rated-load current or the branch-circuit selection current, whichever is greater.§440.32

Transformers

Step or ruleWhat to doOpen to
125 percent limitAt 9 amperes or more, primary-only protection and the secondary device of a both-sides scheme are each limited to 125 percent of that side's current.Table 450.5(B)

Photovoltaic circuits

Step or ruleWhat to doOpen to
125 percent methodMaximum current is the sum of parallel module short-circuit currents times 125 percent.§690.8(A)(1)(a)(1)
Engineered method floorA stamped engineered calculation may not be less than 70 percent of the 125 percent method value.§690.8(A)(1)(a)(3)
Common-return conductorAmpacity is at least the sum of the overcurrent device ratings of the circuits sharing it.§690.8(C)
Strings on one deviceEach string conductor carries the device rating plus the maximum currents of the other strings.§690.8(D)
Mở chương miễn phí →

Câu hỏi người mua thường hỏi

Nhận sách thế nào?

Thanh toán xong, mục tải xuống hiện ngay trên trang này. Liên kết cũng được gửi qua email. Không cần tài khoản.

Nếu sách không hợp thì sao?

Gửi email trong vòng 14 ngày để được hoàn tiền đầy đủ, không cần lý do.

Phần luyện tập miễn phí có bị bỏ không?

Không. Mọi câu hỏi luyện tập, bài thi thử tính giờ và các chương miễn phí trên trang vẫn miễn phí. Cuốn sách là nửa "học", không phải hàng rào quanh phần miễn phí.

Thêm câu hỏi (1)
Đọc trên điện thoại được không?

Được — EPUB cho điện thoại và máy đọc sách, PDF để in và dán tab. Bạn nhận cả hai.

Vì sao mua sách khi phần luyện tập miễn phí?

Câu hỏi luyện tập và bài thi thử tính giờ vẫn miễn phí — không có gì trên trang bị giấu sau cuốn sách này. Cuốn sách $14.99 là nửa "học": chính phần kiến thức, dạy theo trình tự, trong một tệp thuộc về bạn.

  • Dạy có hệ thống — mọi phần thi giảng theo từng chương, từ đầu đến cuối, không chỉ là câu hỏi
  • In ra & dán nhãn — PDF sẵn sàng để in, tô đậm, ghi chú và mang tới bàn học
  • Học mọi nơi, ngoại tuyến — EPUB trên điện thoại hay máy đọc sách; không cần wifi, không cần tab trình duyệt
  • Tất cả một chỗ — các chương và câu hỏi luyện tập trong một tệp
  • Của bạn trọn đời — trả một lần $14.99, tải ngay, không thuê bao

Chính sách hoàn tiền đầy đủ

Chi tiết

Đội ngũ PrepPass · Đối chiếu với the 2026 NEC (NFPA 70), checked section by section in November 2026, and PSI's Texas Department of Licensing and Regulation Electricians Candidate Information Bulletin (updated September 15, 2026) · Quy trình kiểm tra
  • Đối chiếu từ nguồn chính thức(the 2026 NEC (NFPA 70), checked section by section in November 2026, and PSI's Texas Department of Licensing and Regulation Electricians Candidate Information Bulletin (updated September 15, 2026))
  • 409 câu hỏi luyện tập miễn phí

Mua một lần, truy cập tải về trọn đời. eBook là trọn bộ hướng dẫn ôn Texas Master Electrician (TDLR / PSI, 2026 NEC) ở dạng PDF và EPUB. Bản tóm tắt mang tính giáo dục, không phải tư vấn chuyên môn hay pháp lý — luôn xác nhận quy định hiện hành với nguồn chính thức. Cập nhật lần cuối: November 2026.