Framing & StructuralCâu 450 / 700

On a jobsite, prefabricated wood roof or floor trusses must NOT be treated in which of the following ways?

a.Handled with spreader bars to avoid bending during a lift
b.Braced permanently and temporarily as specified by the design
c.Cut, notched, or drilled through chords or webs to run a duct, without the truss designer's approval
d.Stored off the ground and kept from prolonged weather exposure

Giải thích

Truss members are engineered; cutting, notching, or drilling chords or webs without the designer's approval can void the design and cause collapse. Using spreader bars, following the specified bracing, and proper storage are all correct handling practices.

Trích dẫn luật: 2025 CA Residential Code §R502.11

Luyện miễn phí toàn bộ 700 câu hỏi — không cần đăng ký.

Câu hỏi liên quan cùng chủ đề

Cập nhật gần nhất: · quy trình kiểm tra

Đội Ngũ Biên Tập PrepPass · Đối chiếu với California CSLB General Building (B) Trade Examination · Quy trình kiểm tra