Framing & StructuralCâu 452 / 700
On a stairway that turns using winder treads, what is the MINIMUM tread depth measured at the walk line, and the MINIMUM depth at any point of the narrow end?
a.12 inches at the walk line and 8 inches at the narrow end
b.10 inches at the walk line and 6 inches at the narrow end
c.11 inches at the walk line and 10 inches at the narrow end
d.7 inches at the walk line and 4 inches at the narrow end
Giải thích
Winder treads must provide at least 10 inches of depth at the walk line (typically 12 inches from the narrow side) and never less than 6 inches at any point. The other options either overstate the required depths or allow a dangerously narrow 4-inch section at the inside of the turn.
Trích dẫn luật: 2025 CA Residential Code §R311.7.5.2.1Luyện miễn phí toàn bộ 700 câu hỏi — không cần đăng ký.
Câu hỏi liên quan cùng chủ đề
- Under the raised floor of a dwelling, short stud walls between the foundation and the first-floor framing (cripple walls) exceeding a nominal height must be braced primarily to resist what?
- On a jobsite, prefabricated wood roof or floor trusses must NOT be treated in which of the following ways?
- A residential stairway must rise a total of 105 inches from finished floor to finished floor. Using the maximum allowable riser height of 7-3/4 inches, what is the MINIMUM number of risers, and the resulting even riser height?
- On an open stair with a guard, the triangular opening formed by the tread, riser, and bottom rail is limited so that what size sphere cannot pass through?
- In conventional wall framing, where two members of a double top plate are spliced (joints occur), the upper and lower plate joints must be offset by at least how much?
- Behind most exterior siding on a wood-framed wall, the code requires a water-resistive barrier equivalent to at least what?
Cập nhật gần nhất: · quy trình kiểm tra
Đội Ngũ Biên Tập PrepPass · Đối chiếu với California CSLB General Building (B) Trade Examination · Quy trình kiểm tra