SafetyCâu 663 / 700
A contractor wants to use a benched (stepped) excavation wall as the protective system. In which soil is benching NOT permitted?
a.Stable rock
b.Type A soil
c.Type B soil
d.Type C soil
Giải thích
Correct: benching is not allowed in Type C soil because it is too unstable to hold vertical steps; Type C must be sloped, shored, or shielded. Benching is permitted in Type A and Type B soils under the allowable configurations, and stable rock is competent enough to stand vertically. The key limitation is that Type C cannot be benched.
Luyện miễn phí toàn bộ 700 câu hỏi — không cần đăng ký.
Câu hỏi liên quan cùng chủ đề
- A single portable ladder is used repeatedly to access an upper landing. Which combination of practices BEST reduces the risk of the ladder shifting or a worker falling?
- A competent person classifies excavation soil by unconfined compressive strength. Which value range correctly identifies Type B soil?
- CALCULATION: A 6-foot-deep trench in Type A soil will be protected by sloping instead of shoring. Type A allows a maximum slope of 3/4 horizontal to 1 vertical (about 53 degrees). Measured from the trench bottom, how far back from the edge (horizontal run on each side) must the top of the slope extend?
- CALCULATION: A trench 5 feet deep and 100 feet long requires a means of egress so no worker travels more than 25 feet of lateral distance to reach a ladder. What is the MINIMUM number of ladders needed, spaced so every point is within that distance?
- Before mechanized digging begins, an excavator must have underground utilities located and marked. In California, what is the general requirement for notifying the regional notification center (DigAlert / 811)?
- Workers will enter a 7-foot-deep excavation next to a former solvent storage area where a hazardous atmosphere could exist. Under Cal/OSHA, what is required before and during entry?