A contractor plans to join copper tubing to galvanized steel pipe directly. The BEST practice to avoid a common failure is to:
a.Weld the two metals together
b.Use extra pipe dope only
c.Wrap the joint in tape
d.Install a dielectric union or fitting to prevent galvanic corrosion between dissimilar metals
Giải thích
Directly coupling copper and galvanized steel creates a galvanic cell that corrodes the connection; a dielectric union or fitting isolates the metals electrically to prevent this. Welding dissimilar metals, extra dope, or tape does not stop galvanic corrosion.
Trích dẫn luật: 2025 CA Plumbing CodeLuyện miễn phí toàn bộ 700 câu hỏi — không cần đăng ký.
Câu hỏi liên quan cùng chủ đề
- A garden hose is left submerged in a utility sink filled with soapy water while the faucet is on. This creates a cross-connection hazard because:
- Horizontal copper water piping must be supported at intervals so it does not sag and strain joints. Compared with copper, plastic (PEX or CPVC) piping generally requires:
- An island sink uses a special loop vent because there is no adjacent wall to run a conventional vent up through. This island (loop) vent works by:
- CALCULATION: A vertical drainage stack must accommodate horizontal branch offsets. A trap arm for a 2-inch fixture drain is allowed a maximum developed length. If the code table permits 8 feet for a 2-inch trap arm, and the layout requires 11 feet to the vent, the installer should:
- A vent terminating through the roof must extend a minimum height above the roof and be set back from any vertical surface or opening, MAINLY to:
- A gas furnace is installed in a small, tightly sealed closet with no combustion air openings. The MOST likely dangerous consequence is:
Cập nhật gần nhất: · quy trình kiểm tra
Đội Ngũ Biên Tập PrepPass · Đối chiếu với California CSLB General Building (B) Trade Examination · Quy trình kiểm tra