InstallationCâu 35 / 110
What is the function of the reversing valve in a heat pump?
a.To meter refrigerant into the evaporator
b.To change the direction of refrigerant flow between heating and cooling
c.To drain condensate
d.To regulate gas pressure
Giải thích
The reversing valve redirects refrigerant flow so the same equipment can both heat and cool by switching which coil is the condenser and which is the evaporator. It is energized or de-energized depending on the manufacturer's design. A stuck valve is a common heat-pump service issue.
Luyện miễn phí toàn bộ 110 câu hỏi — không cần đăng ký.
Câu hỏi liên quan cùng chủ đề
- A properly installed refrigerant line set should have the liquid line and suction line sized according to what?
- On a long vertical suction riser, what feature helps ensure compressor oil returns properly?
- In a split-system heat pump, the outdoor coil functions as the condenser during which mode?
- A package unit differs from a split system in what way?
- Gas piping for a furnace must be sized primarily to do what?
- What is the purpose of a sediment trap (drip leg) installed near a gas appliance?
Cập nhật gần nhất: · quy trình kiểm tra
Đội Ngũ Biên Tập PrepPass · Đối chiếu với California CSLB C-20 Warm-Air HVAC Trade Exam · Quy trình kiểm tra