An indirect-waste standpipe receiving a domestic clothes washer must have a trap, and the standpipe height above the trap weir must generally be within what range?
a.6 to 12 inches
b.12 to 16 inches
c.18 to 30 inches (457–762 mm)
d.36 to 48 inches
Giải thích
A clothes-washer standpipe must be trapped and vented, and the standpipe usually extends between 18 and 30 inches above the trap weir. Too short a standpipe can overflow during the wash pump-out; too tall creates back-pressure and slow draining. The trap is set at an accessible height below the standpipe.
Trích dẫn luật: 2022 California Plumbing Code (CPC) §804.0Luyện miễn phí toàn bộ 360 câu hỏi — không cần đăng ký.