Thoát nước, Nước thải & Thông hơiCâu 161 / 360
A combination waste-and-vent system is chiefly intended for…
a.floor drains, sinks, and similar fixtures where conventional venting is impractical, using oversized horizontal piping
b.a battery of water closets
c.roof (storm) drainage
d.water-heater relief piping
Giải thích
A combination waste-and-vent system uses oversized horizontal drain piping that carries both waste and air, providing venting for fixtures like floor drains and sinks in large open areas where a conventional vent cannot be run. Water closets and other high-discharge fixtures are generally not permitted on this system. The oversized pipe flows only partially full so air can move above the waste.
Trích dẫn luật: 2022 California Plumbing Code (CPC) §910.0Luyện miễn phí toàn bộ 360 câu hỏi — không cần đăng ký.
Câu hỏi liên quan cùng chủ đề
- A small under-the-sink hydromechanical grease trap rated to PDI standards commonly has a flow rating such as…
- An indirect-waste standpipe receiving a domestic clothes washer must have a trap, and the standpipe height above the trap weir must generally be within what range?
- What distinguishes an 'air break' from an 'air gap' in an indirect waste installation?
- As a vent extends upward toward its terminal, its required diameter…
- Two fixtures set on the same floor level and connecting to a common vertical drain within the required distance may share…
- Where a building (house) trap is installed on the building drain, it is commonly accompanied by…
Cập nhật gần nhất: · quy trình kiểm tra
Đội Ngũ Biên Tập PrepPass · Đối chiếu với California CSLB C-36 Plumbing Trade Examination · Quy trình kiểm tra