Thoát nước, Nước thải & Thông hơiCâu 162 / 360
As a vent extends upward toward its terminal, its required diameter…
a.may be reduced by half at the roof
b.must not be reduced (no decrease in size in the direction of the terminal)
c.may be reduced to 1/2 inch above the roof
d.must double at every branch
Giải thích
A vent may not be reduced in size in the direction of flow toward the outlet; the required diameter is maintained or increased, never decreased, up to the terminal. Reducing the vent would restrict airflow and could allow frost or debris to close it. This is separate from the frost-closure rule that enlarges the terminal in cold climates.
Luyện miễn phí toàn bộ 360 câu hỏi — không cần đăng ký.
Câu hỏi liên quan cùng chủ đề
- An indirect-waste standpipe receiving a domestic clothes washer must have a trap, and the standpipe height above the trap weir must generally be within what range?
- What distinguishes an 'air break' from an 'air gap' in an indirect waste installation?
- A combination waste-and-vent system is chiefly intended for…
- Two fixtures set on the same floor level and connecting to a common vertical drain within the required distance may share…
- Where a building (house) trap is installed on the building drain, it is commonly accompanied by…
- In a horizontal wet-vent system, how must the wet-vented pipe (which carries both waste and air) be sized?