Two fixtures set on the same floor level and connecting to a common vertical drain within the required distance may share…

a.a single trap for both
b.one backwater valve
c.a common vent, provided the drain and vent are sized for both fixtures
d.one cleanout only

Giải thích

Two fixtures at the same level connecting to a shared vertical drain within the code distance may be served by a common vent, with the connecting drain and vent sized for the combined load. Each fixture still has its own trap; a single trap serving two fixtures is generally prohibited. Common venting saves piping for back-to-back layouts.