Thiết bị & Bình nước nóngCâu 224 / 360
A floor drain located in a room that is used infrequently may lose its trap seal by evaporation. The approved way to keep the seal is to provide:
a.a larger trap arm
b.a second floor drain nearby
c.a trap primer or an approved trap seal protection device
d.a deeper cleanout
Giải thích
In little-used areas, water in a floor drain trap can evaporate and let sewer gas enter. A trap primer periodically adds water to maintain the seal, or an approved barrier-type trap seal device may be used. This keeps the required 2-to-4-inch seal intact.
Luyện miễn phí toàn bộ 360 câu hỏi — không cần đăng ký.
Câu hỏi liên quan cùng chủ đề
- Water hammer arrestors are installed on a water distribution system primarily to:
- An outdoor hose bibb (sillcock) must be protected against backflow by:
- Each fixture supply to a lavatory or water closet is commonly fitted with an angle stop primarily to:
- A water heater installed in an attic must be reached by a passageway and working platform. A typical minimum requirement is a solid, continuous passageway not less than:
- Cross-connection control in a potable water system is intended to:
- A plumber replaces a water heater in a finished basement over a slab where a leak would not damage anything below, but the local code still requires spill protection. If a drain pan is installed, its drain must:
Cập nhật gần nhất: · quy trình kiểm tra
Đội Ngũ Biên Tập PrepPass · Đối chiếu với California CSLB C-36 Plumbing Trade Examination · Quy trình kiểm tra