For residential construction where conventional fall protection is infeasible or creates a greater hazard, what does OSHA require of the employer at heights of 6 feet or more?
解析
Where the employer demonstrates that conventional fall protection is infeasible or would create a greater hazard, the substitute is a written, site-specific fall protection plan prepared by a qualified person - federally under 1926.502(k), and in California under section 1671.1, which adds that the plan must be kept at the job site, that any change needs the qualified person's approval, and that implementation is supervised by a competent person. Section 1671.1(a) also states a presumption that conventional protection IS feasible and puts the burden of rebutting it on the employer, so recording the claim in a tailgate meeting (a) proves nothing. Warning lines (b) and safety monitors (c) belong to low-slope roofing work under narrow conditions, not to framing.
法律依据: 29 CFR 1926.501(b)(13); 1926.502(k); 8 CCR §1671.1; §1716.2(e)免费刷完整 1632 道题库 — 无需注册。
Own the complete CSLB Law & Business guide — PDF + EPUB, $24.99 →
同考点相关题目
- A personal fall arrest system (PFAS) generally consists of which components?
- Anchorages used to attach personal fall arrest equipment must be capable of supporting at least how much per employee, or be designed with a safety factor of at least two under a qualified person's supervision?
- A worker must pass by or work near a floor hole or skylight opening. What protection is required?
- A guardrail system used for fall protection must have a top rail capable of withstanding a downward/outward force of at least how much, applied within 2 inches of the top edge?
- The top edge of a standard guardrail top rail must be approximately what height above the walking/working surface?
- At what depth does an excavation generally require a protective system such as sloping, shoring, or shielding to protect workers from cave-ins?