A vending machine repair company sends technicians to recover refrigerant from beverage coolers in the field. These sealed factory-charged coolers hold about 2 pounds of R-134a. Under Section 608 they are treated as:

a.Type II high-pressure appliances requiring 10 inches Hg vacuum
b.Small appliances subject to the 80%/90% (or 4 inches Hg) recovery rules
c.Low-pressure appliances requiring 25 mm Hg absolute
d.Motor vehicle air conditioners under Section 609

解析

Factory-sealed beverage vending machines and coolers holding five pounds or less of refrigerant are small appliances. Recovery must reach 80% (compressor off) or 90% (compressor on), or the alternative of 4 inches Hg vacuum. They are not Type II, Type III, or motor vehicle appliances.

法律依据: 40 CFR §82.156

免费刷完整 240 道题库 — 无需注册。

同考点相关题目

最近核对: · 审核流程

PrepPass 编辑团队 · 依据官方资料核对 EPA Section 608 Technician Certification Exam · 我们如何核对
反馈