California Civil Engineer: Seismic Principles Practice Test

Sample practice questions

A few real questions from this free bank, with full explanations. Use the practice tool above for the whole set.

  1. 1. Seismic Data and Design Criteria

    A site has a mapped risk-targeted short-period spectral acceleration Ss = 1.50g and a short-period site coefficient Fa = 1. What is the design spectral response acceleration SDS?

    • a.0.750g
    • b.1.000g
    • c.1.500g
    • d.2.250g

    Answer: b

    Explanation: ASCE 7-16 Section 11.4.4 adjusts the mapped value for site class: SMS = Fa x Ss = 1 x 1.50 = 1.500g. Section 11.4.5 then takes two-thirds of it: SDS = (2/3)(1.500) = 1.000g. Stopping at 1.500g reports the MCER value SMS, not the design value, and multiplying by 1.5 inverts the two-thirds factor.

  2. 2. Seismic Characteristics of Engineered Systems

    At a story, total unfactored vertical load above is Px = 3,600 kips, design story drift is 1.5 in., story shear is Vx = 500 kips, story height is 144 in., Cd = 4 and Ie = 1.25. What is the stability coefficient theta?

    • a.0.012
    • b.0.016
    • c.0.019
    • d.0.023

    Answer: d

    Explanation: ASCE 7-16 Eq. 12.8-16: theta = Px x Delta x Ie / (Vx x hsx x Cd) = (3,600 x 1.5 x 1.25) / (500 x 144 x 4) = 6,750 / 288,000 = 0.023. Leaving Cd out of the denominator gives 6,750 / 72,000 = 0.094, which overstates theta fourfold. P-delta effects need not be considered when theta is 0.10 or less.

  3. 3. Seismic Vulnerability and Improvement of Structural Systems

    Several precast concrete parking structures collapsed in the Northridge earthquake. Which deficiency was a principal contributor?

    • a.Gravity framing and connections that could not tolerate the lateral drift
    • b.Foundations that were supported on rock rather than on soil
    • c.Shear walls that were far stronger and stiffer than the design forces required
    • d.Use of cast-in-place topping slabs with too much reinforcing steel

    Answer: a

    Explanation: Gravity columns and precast connections that were not part of the lateral system could not accommodate the drift, and thin toppings with brittle mesh and weak collectors could not deliver forces to the walls. The lesson is the deformation compatibility requirement of ASCE 7-16 Section 12.12.5 and stronger collector and diaphragm provisions.

  4. 4. Seismic Forces: Building Structures

    Lateral seismic forces on a 4-story building are 45 kips at level 2, 85 kips at level 3, 120 kips at level 4, 150 kips at roof. What is the seismic story shear in the story immediately below level 4?

    • a.120 kips
    • b.270 kips
    • c.338 kips
    • d.400 kips

    Answer: b

    Explanation: ASCE 7-16 Eq. 12.8-13: the story shear is the sum of the lateral forces at and above that story: 120 + 150 = 270 kips. Using only the force at level 4 (120 kips) omits what is delivered from the levels above, and summing the forces below the story runs the load path backward.

  5. 5. Seismic Forces: Building Structures

    Why does the importance factor Ie of 1.5 for a hospital increase its design base shear?

    • a.It corrects the mapped ground motion for near-fault effects
    • b.It converts strength-level forces to allowable stress levels
    • c.It accounts for the heavier equipment found in a hospital
    • d.It lowers the effective R, limiting inelastic demand and damage

    Answer: d

    Explanation: Cs = SDS/(R/Ie): Ie effectively reduces R, so the essential facility is designed for higher forces and will experience less inelastic deformation, improving the chance of remaining operational. Equipment weight is captured in W and near-fault effects in the mapped accelerations and S1-based minimum.

  6. 6. Seismic Forces: Non-Building Structures, Components and Equipment

    A rigid nonbuilding structure (fundamental period less than 0.06 s) weighs 150 kips including operating contents. SDS = 1g, Ie = 1. What is the design lateral force?

    • a.7 kips
    • b.45 kips
    • c.60 kips
    • d.150 kips

    Answer: b

    Explanation: ASCE 7-16 Section 15.4.2 (Eq. 15.4-5): V = 0.30 SDS W Ie = 0.30 x 1 x 150 x 1 = 45 kips, distributed with height according to the mass distribution. A rigid structure moves with the ground, so no R factor and no period-based reduction apply; the 0.044 SDS Ie expression is a minimum Cs for flexible structures, not the rigid-structure force.

  7. 7. Seismic Forces: Non-Building Structures, Components and Equipment

    Active mechanical equipment with Ip = 1.5 that must remain operable after the design earthquake requires what, in addition to anchorage design?

    • a.Special certification by shake-table testing or experience data
    • b.An annual inspection performed by the local fire marshal
    • c.A waiver of the relative displacement requirements for piping
    • d.A doubling of the anchor bolt diameter over the calculated size

    Answer: a

    Explanation: ASCE 7-16 Section 13.2.2 requires active mechanical and electrical equipment that must remain operable (designated seismic systems) to be certified by the manufacturer through approved shake-table testing or experience data. Anchorage alone keeps equipment in place but does not show it will still run.

  8. 8. Seismic Analysis Procedures

    A rigid diaphragm with no torsion delivers a story shear of 240 kips to 3 parallel shear walls with relative rigidities A = 1, B = 1, C = 4. What shear does wall A resist?

    • a.30.0 kips
    • b.40.0 kips
    • c.80.0 kips
    • d.200.0 kips

    Answer: b

    Explanation: With a rigid diaphragm, walls displace equally and share force in proportion to rigidity: V_A = V x R/sum(R) = 240 x 1/6 = 40.0 kips. An equal split (80.0 kips each) or a tributary-width split would be the logic for a flexible diaphragm, not a rigid one.

  9. 9. Seismic Analysis Procedures

    A one-story steel frame has 6 identical columns, each with I = 500 in.^4, E = 29,000 ksi and height 12 ft. The columns are fixed at the base and pinned at the top. What is the lateral stiffness of the story?

    • a.14.6 kips/in.
    • b.87.4 kips/in.
    • c.125.9 kips/in.
    • d.349.6 kips/in.

    Answer: b

    Explanation: Each column contributes k = 3EI/h^3 (cantilever, fixed-pinned): 3 x 29,000 x 500/(144)^3 = 14.6 kips/in. For 6 columns in parallel, k = 87.4 kips/in. The coefficient 12 would apply if the top were restrained against rotation, a fourfold difference in stiffness.

  10. 10. Seismic Detailing and Construction Quality Control

    What is the purpose of boundary elements in a special reinforced concrete shear wall?

    • a.To eliminate the need for horizontal shear reinforcement in the wall web
    • b.To provide a ledge for supporting the floor diaphragm framing
    • c.To isolate the wall from the foundation with a sliding joint
    • d.To confine the highly compressed wall edges so they sustain large strains

    Answer: d

    Explanation: Under overturning, the wall ends see high compressive strain; closely tied boundary elements confine the concrete and prevent bar buckling so the wall can yield in flexure without crushing. They do not replace web shear reinforcement.