California Structural Pest Control Field Representative Exam — Branch 3 (Termite / Wood-Destroying) — All Questions
99 questions
Before a company may issue any statement about wood-destroying pests at a property, what must happen?
- a.The county must approve the work order
- b.A Branch 3 field representative or operator must inspect✓
- c.A Branch 2 licensed applicator must look over the subarea
- d.The owner must sign a waiver of inspection
Section 8516 bars work and any statement on the presence or absence of wood-destroying pests until a licensed Branch 3 field representative or operator employed by a registered company has inspected.
What does a complete inspection cover?
- a.All visible and accessible portions of the structure✓
- b.Only the subarea, the attic and the attached garage framing
- c.Every concealed void in the building, opened as necessary
- d.Only the rooms and outbuildings that the owner selects in advance
Section 1993 defines a complete report as the report of an inspection of all visible and accessible parts. Concealed areas are listed as inaccessible, not opened.
What is a faulty grade level?
- a.The top of the foundation is at or below the adjacent soil✓
- b.The soil slopes away from the house too steeply
- c.The driveway sits higher than the street in front of the house
- d.The subarea soil is more than 18 inches below the floor joists
Section 1990 says a faulty grade exists when the top of any foundation is even with or below the adjoining earth, with the existing earth level taken as grade.
How much clear space below the floor joists makes a subarea reportable as lacking clearance?
- a.Less than 24 inches
- b.Less than 6 inches
- c.Less than 12 inches✓
- d.Less than 18 inches
Section 1990 lists areas with less than 12 inches between the bottom of the joists and the unimproved ground as a condition likely to lead to infestation.
How does the regulation define excessive cellulose debris?
- a.Any sawdust or wood shavings visible on the soil
- b.Debris of a size that can be raked, or larger✓
- c.Wood pieces more than four feet long
- d.Debris weighing more than ten pounds in total
Section 1990 uses the rake test. Shavings too small to rake are not excessive, but stumps and wood embedded in footings are reportable.
A wooden form board is found left in the soil against a footing. How is it reported?
- a.As a roof condition to be referred to a roofer
- b.As a faulty grade level and an inaccessible area
- c.As cellulose debris and an earth-wood contact✓
- d.As an inaccessible area needing further inspection
Wood left in or on the soil feeds subterranean termites and gives them a path to the structure. It is neither a grade nor an access issue.
Which is an earth-wood contact?
- a.A redwood deck on metal brackets set above a concrete slab
- b.A sill plate on a concrete stem wall eight inches above soil
- c.A fence post nailed to the house and set in soil✓
- d.A window frame set in a stucco wall well above grade
Wood touching soil and connected to the building bridges the foundation. The other examples keep wood separated from the ground.
Why is an earth-filled planter against a wall reported?
- a.It attracts drywood swarmers to the wall in summer
- b.It raises soil against the siding or framing✓
- c.It shades the foundation and keeps the stem wall cool
- d.It weakens the concrete of the foundation wall
Planter soil above the foundation line creates a faulty grade and moisture against wood. Section 1991 names earth fill planters among conditions to correct.
What is meant by a commonly controllable moisture condition?
- a.One caused by the regional climate, which no owner could change
- b.One that exists to some degree in every subarea in the whole state
- c.One, such as a plumbing leak, that can ordinarily be corrected✓
- d.One found only in coastal districts, where summer fog is common
Section 1990 lists commonly controllable moisture conditions that would foster fungus. Leaks, poor drainage and blocked vents are examples.
Which subarea finding is a condition likely to lead to infection?
- a.A concrete pier set under each wooden post
- b.Vents blocked by soil and stored goods✓
- c.Sound, dry mudsills on a raised foundation
- d.A vapour barrier laid over the subarea soil
Insufficient ventilation raises humidity and wood moisture. The other items reduce the risk.
Want these explained in order? Branch 3 Field Representative Exam — California Termite Study Guide, 2027 Edition — PDF + EPUB, $14.99 · 14-day refund →
Where is the inspection tag posted?
- a.In the attic, the subarea or the garage✓
- b.In the kitchen, under the sink or beside the meter
- c.On the electrical panel beside the main breaker
- d.On the front door, the back door or a window
Section 1996.1 requires a tag in the attic or subarea, or in the garage, whenever an inspection for wood-destroying pests is made.
What is the minimum size of an inspection tag?
- a.5 by 7 inches
- b.1 by 2 inches
- c.8 by 10 inches
- d.3 by 5 inches✓
The regulation sets a minimum of three inches by five inches for both inspection and completion tags.
What must an inspection tag show?
- a.The price of the inspection and the terms of payment agreed
- b.The inspector's home address and personal telephone number
- c.The pests found, the estimated repair cost and the guarantee
- d.The firm's name, the date and a do-not-remove statement✓
Section 1996.1 requires the firm's name, the inspection date and the statement referring to the regulation. Findings belong in the report.
The inspector finds another company's inspection tag dated eight months ago. What must be done?
- a.Remove it and post a new one in its place
- b.Cover it completely with the new tag
- c.Note its presence in the report✓
- d.Ignore it
The report must indicate any other inspection or fumigation tag less than two years old, and a registered company shall not remove any tag.
How old may another company's tag be and still have to be noted in the report?
- a.Less than five years
- b.Less than six months
- c.Less than two years✓
- d.Any age
Section 1996.1 requires the report to indicate other inspection or fumigation tags that are less than two years old.
The inspector cannot enter part of the attic because of low clearance. How is this handled?
- a.It is left out of the report and off the diagram
- b.It is described as free of infestation, like the rest
- c.It is described as infested
- d.It is listed as not inspected, with the reason✓
Section 1990 requires the licensee to state specifically which areas were not inspected and why. No opinion is given on areas not seen.
Which area may be treated as inaccessible if the report says so and gives the reason?
- a.The exterior siding at ground level
- b.The open framing of the garage
- c.The interior of hollow walls✓
- d.The accessible subarea under the floor
Section 1990 lists hollow wall interiors, furnished interiors, built-in cabinet work and floors beneath coverings among such areas.
Stored boxes fill a garage wall to the ceiling. What does the inspector report?
- a.That the owner refused the inspection of the garage entirely
- b.That the owner refused inspection of the garage
- c.That storage made inspection of the wall impracticable✓
- d.Nothing about the wall, as it was blocked
Areas where storage conditions prevent inspection are stated as not inspected, with a recommendation for further inspection if practicable.
What must be recommended for an area that could not be inspected?
- a.Removal of the area
- b.Fumigation of the whole structure
- c.A second opinion from the county commissioner
- d.Further inspection, if practicable✓
Section 8516 calls for a description of inaccessible areas with a recommendation for further inspection where practicable.
A wooden deck touches the house. What does the regulation require?
- a.It is reported only if it has been painted
- b.It is excluded as a detached structure
- c.Information on it must be reported✓
- d.It is reported only if the owner requests it
Section 1990 requires information on any wooden deck, stairs or landing in exterior exposure attached to or touching the structure.
Want these explained in order? Branch 3 Field Representative Exam — California Termite Study Guide, 2027 Edition — PDF + EPUB, $14.99 · 14-day refund →
Part of an attached deck cannot be seen from below. How is that part reported?
- a.As infested by default
- b.As inaccessible✓
- c.As Section II
- d.As sound and free of damage
Portions of decks, stairs and landings not available for visual inspection must be designated inaccessible.
How long is a stall shower water tested when the base can be filled?
- a.At least 15 minutes✓
- b.At least 5 minutes
- c.At least 1 minute
- d.At least 60 minutes
Section 1991 calls for plugging the drain, filling the base and testing for a minimum of fifteen minutes.
To what level is the shower base filled for the water test?
- a.Half an inch above the top of the drain
- b.Exactly three inches below the top of the dam
- c.Level with the top row of the wall tile
- d.Within one inch of the top of the dam✓
The base is filled to within one inch of the top of the shower dam so that the pan and its joint with the dam are tested.
How is a stall shower with no dam tested?
- a.It is exempt from any inspection or water test under the rule
- b.By plugging the drain and filling it for fifteen minutes
- c.By spraying the walls and the door for at least one full hour
- d.By running water on the unplugged base for five minutes✓
Showers with no dam, or less than two inches to the top of the dam, are tested by running water on the unplugged base for at least five minutes.
A stall shower is over a finished ceiling. What does the regulation require?
- a.A fifteen-minute water fill test
- b.Removal of the ceiling
- c.No inspection
- d.Inspection, but no water test✓
Showers over finished ceilings must be inspected but need not be water tested, since a leak would damage the ceiling below.
Water stains are seen on the ceiling below an upstairs shower. What is recommended?
- a.Further inspection and testing✓
- b.Fumigation of the bathroom
- c.Painting the ceiling
- d.A fifteen-minute fill test
Where stains are evident below a shower over a finished ceiling, section 1991 calls for a recommendation for further inspection and testing.
Which statement about the roof must appear in the report?
- a.The estimated remaining life of the present roof covering
- b.Whether the exterior surface of the roof was inspected✓
- c.The name and licence of the last roofing contractor to work there
- d.The age of the roof covering and the year it was installed
Section 8516 requires one of two bold statements: that the exterior roof surface was not inspected, or that it was inspected for wood-destroying pests.
If the roof exterior was not inspected, whom does the report advise the reader to contact about water tightness?
- a.A roofing contractor licensed by the Contractors State License Board✓
- b.The county agricultural commissioner for the property's county
- c.The local fire department or building department
- d.A Branch 1 fumigator registered with the Board
The statutory statement directs anyone wanting the roof's water tightness determined to a licensed roofing contractor.
Which parts of the roof structure are within the inspection?
- a.Only the shingles, the ridge capping and the gutters
- b.Eaves, rafters, fascias and exposed sheathing✓
- c.Only the gutters and the downpipes at each corner
- d.Only the chimney flashing and the roof covering itself
Section 8516 lists roof framing including eaves, rafters, fascias, exposed timbers, exposed sheathing, ceiling joists and attic walls.
What does the inspector check at foundation vents?
- a.That they are sealed for the winter months
- b.That they are painted to match the wall colour
- c.That they are open and above soil level✓
- d.That they face north
Blocked or buried vents cause insufficient ventilation and can let soil reach wood. Both are reportable conditions.
Which subarea observation indicates excessive moisture?
- a.Dust lying evenly on the soil beneath the joists
- b.Standing water or efflorescence on the foundation✓
- c.Dry, cracked soil across the subarea
- d.Cobwebs between the joists and girders
Standing water, damp soil, white mineral deposits and condensation on pipes show a moisture problem that can lead to infection.
What personal equipment is basic to a subarea inspection?
- a.A respirator alone, worn throughout
- b.A calculator and a camera, with nothing else
- c.Coveralls, light, probe and gloves✓
- d.No equipment beyond a flashlight is needed
The inspector must crawl, light and probe timbers safely. A probing tool and a strong light are essential.
Why does an inspector probe mudsills near the access opening and at plumbing?
- a.Probing there strengthens the wood
- b.The regulation forbids probing timbers elsewhere
- c.These timbers are always redwood heartwood
- d.These are frequent sites of decay and termite entry✓
Sills near leaks, vents and soil contact are the most likely to be damaged. Probing confirms what sounding suggests.
Which exterior feature often conceals termite entry?
- a.A concrete splash block under a downpipe
- b.A metal downpipe strapped to the stucco wall
- c.A brick chimney cap well above the roof line
- d.Stucco that extends below the soil line✓
Stucco carried into the soil hides the foundation and lets termites travel behind it. Loose stucco is also named in section 1991.
What is a cold joint, in a slab foundation?
- a.A gap in attic insulation
- b.A seam between separate concrete pours✓
- c.A joint in a heating duct
- d.A plumbing union under the slab
Termites enter through cracks and seams in concrete, including joints between separately poured sections and around pipes.
An attached garage has unfinished walls. What should the inspector examine closely?
- a.The garage door spring and its tracks
- b.The oil stains and tyre marks on the floor
- c.Sill plates and the base of studs at the slab✓
- d.The light fittings on the ceiling
Garage sills sit close to soil and slab edges and are often wetted, so they are common sites of termites and decay.
Which finding in an attic suggests a roof leak?
- a.Clean, bright nails
- b.An even layer of dust on top of the insulation
- c.Paper-faced insulation between the ceiling joists
- d.Dark water stains on sheathing and rafters✓
Evidence of roof leaks is a listed condition. Stains and decayed sheathing are noted even when the roof exterior is not inspected.
An owner refuses access to one bedroom. What goes in the report?
- a.That the room was not inspected, and why✓
- b.That the room was free of pests and damage
- c.That the inspection was complete and nothing was found
- d.Nothing
Any area not inspected is stated with the reason. The inspection remains what was actually done.
What kind of inspection covers only part of a structure?
- a.Limited inspection✓
- b.Complete inspection
- c.Reinspection
- d.Supplemental inspection
Section 1993 defines a limited report as a report on only part of a structure, with a diagram of the area inspected.
What must a limited report recommend?
- a.A reinspection of the same area within four months
- b.Nothing beyond the area that was actually inspected
- c.Fumigation
- d.Further inspection of the entire structure✓
A limited report must show which portions were inspected, name who requested it, and recommend further inspection of the entire structure.
What must be done before a termite bait station is installed?
- a.A full or limited inspection of the structure✓
- b.Nothing at all; baiting never needs an inspection
- c.A fumigation of the whole structure by a Branch 1 firm
- d.A soil test by the county agricultural commissioner
Section 1993.2 requires a full or limited inspection before installation and treats bait station use as a control service agreement.
Which statement about a termite monitoring device is correct?
- a.It contains no pesticide and gives no control✓
- b.It replaces the need for a Branch 3 inspection
- c.It positively identifies an active infestation
- d.It may be installed by any company, in any branch
Section 1993.4 defines a monitoring device as one that only indicates possible presence, contains no pesticide, and must be installed by a registered Branch 3 company.
What must be given to the owner before a termite monitoring device is installed?
- a.A written disclosure of what the device does and does not do✓
- b.A building permit issued by the city
- c.A fumigation notice naming the fumigant and re-entry date
- d.A lien release signed by the company
The regulation prescribes disclosure language explaining that devices do not replace an inspection by a licensed inspector.
During inspection the licensee sees damage that may need a building permit to repair. What is required?
- a.The owner is told orally, with nothing in writing
- b.The city building department is notified by the company
- c.The need for a permit is noted on the report✓
- d.Nothing
Section 1991 says that if, in the inspector's opinion, a building permit is required, it must be noted on the inspection report.
Which detail belongs on the diagram in the report?
- a.The furniture layout in each room
- b.The colour and floor covering of each room
- c.The approximate location of infested or infected areas✓
- d.The location of the owner's vehicles and furniture
Section 8516 requires a foundation diagram or sketch showing where infestations, infections and conducive conditions are evident.
How are damaged members identified in the report?
- a.By standard construction names such as studs, joists and fascia✓
- b.By the inspector's own code numbers from the field notes
- c.By the room that they happen to be nearest to
- d.By colour codes marked on the diagram
The statute requires infested or infected members to be listed so as to identify them clearly, as is typical of standard construction components.
Who may perform the inspection for a registered company?
- a.Any employee with two years' experience in the trade
- b.A licensed applicator on the crew
- c.A Branch 2 field representative it employs
- d.A Branch 3 field representative or operator it employs✓
Only a licensed Branch 3 field representative or operator employed by the registered company may inspect and report.
A real estate agent telephones to say, "Just look at the garage." What kind of report results?
- a.No report is needed
- b.A supplemental report to the last complete one
- c.A complete report on the whole of the structure
- d.A limited report naming who requested it✓
An inspection of part of a structure produces a limited report, which names the person or agency requesting the limitation.
Granting permission to inspect is treated as what, under the regulations?
- a.A contract for repairs
- b.An authorisation to fumigate
- c.A waiver of the report
- d.A request for an inspection✓
Section 1996 provides that granting permission to make an inspection is deemed a request, so a report must follow even if the inspection was free.