California Structural Pest Control Field Representative Exam — Branch 3 (Termite / Wood-Destroying) — All Questions
57 questions
A downpipe discharges against the foundation. What is the correction?
- a.Extend it to carry water away from the building✓
- b.Block it with a watertight cap fitted at the bottom
- c.Shorten it so that it ends higher on the wall
- d.Point it into the nearest foundation vent
Roof water at the foundation raises subarea moisture. Carrying it away is a simple controllable correction.
Sprinklers strike the wood siding each morning. Which correction is appropriate?
- a.Add more sprinklers along the same wall
- b.Repaint the siding every year to seal it
- c.Fumigate the wall and the framing behind it
- d.Adjust or relocate the sprinkler heads✓
Removing the wetting removes the cause. Paint slows but does not prevent decay where wood is wetted daily.
What should a completion notice say about recommendations the owner declined?
- a.Nothing at all, since the owner declined to have them done
- b.That they are no longer needed for the certification to issue
- c.That they were completed
- d.That they were not completed, with an estimated cost✓
Section 8518 requires the notice to state recommendations not completed and their estimated cost.
Which wood members are named in the statute as parts to identify when infested?
- a.Pipes, wires, ducts, gas meters, water heaters, switches, outlets and light fittings
- b.Carpets, floor tiles, paint, wallpaper and window blinds
- c.Siding, studs, rafters, floor joists, fascia, subfloor, sheathing and trim✓
- d.Doors, locks, hinges, handles and window catches only
Section 8516 lists these standard components as examples of how to identify infested or infected members clearly.
What is the first step in any corrective repair of fungus damage?
- a.Apply a finish coat to the damaged area
- b.Post the completion tag beside the inspection tag
- c.Order the replacement timber for the repair
- d.Find and stop the source of moisture✓
Without moisture correction the fungus continues. Regulation 1991 ties every fungus repair to correcting the moisture condition.
Old drywood pellets remain in an attic after treatment. What is done with them?
- a.They are removed or covered✓
- b.They are mixed into the insulation
- c.They are mailed to the Board
- d.They are left to show past activity
Regulation 1991 calls for removing or covering accessible pellets and frass so that any fresh pellets signal new activity.
A weakened stair stringer on an attached exterior stair is found. What is recommended?
- a.Replace or reinforce the stringer✓
- b.Paint it
- c.Leave it out, since stairs are excluded
- d.Report it as inaccessible
Attached exterior stairs are within the report, and structurally weakened members are replaced or reinforced.