301 questions

Reporting and Recordkeeping

To whom is the inspection report delivered?

  • a.The person requesting it and the property owner or agent✓
  • b.The neighbouring owners on each side
  • c.The county recorder and the agricultural commissioner
  • d.The Board, in every case, and no one else

The report goes to whoever requested the inspection and to the owner or the owner's designated agent. The Board receives the property address, not the report, unless it demands a copy.

Reporting and Recordkeeping

By when must the address of an inspected property be filed with the Board?

  • a.No later than 10 business days after the inspection begins✓
  • b.Within 90 days of the inspection
  • c.Within 24 hours of the start of inspection, by telephone
  • d.Only when repair work is contracted for

Section 8516 requires the address to be reported on the Board's form within 10 business days after the commencement of an inspection or upon completed work.

Reporting and Recordkeeping

What is the maximum fine for failing to file the address of an inspected property?

  • a.$10,000
  • b.$2,500✓
  • c.$500
  • d.$250

Failure to report and file is grounds for discipline and subjects the registered company to a fine of not more than $2,500.

Reporting and Recordkeeping

How long must inspection reports and field notes be kept?

  • a.Three years✓
  • b.Twelve years
  • c.Ten years
  • d.Eighteen months

The registered company retains inspection reports, field notes and activity forms for three years.

Reporting and Recordkeeping

The Board demands a copy of an inspection report. How quickly must it be submitted?

  • a.Within twenty-four hours
  • b.Within two business days✓
  • c.Within thirty days
  • d.Within ten business days

Section 8516 requires reports or copies to be submitted to the Board upon demand within two business days.

Reporting and Recordkeeping

A company gives a five-year guarantee. How long must it keep the related records?

  • a.For three years only, exactly as with any other report
  • b.For the guarantee period and one year after✓
  • c.For ten years from the date of the original report
  • d.Until the property is next sold or refinanced

Where a guarantee runs beyond three years, records are kept for its duration and for one year after it expires.

Reporting and Recordkeeping

Which report must be delivered before work starts?

  • a.The notice of work completed
  • b.The monthly activity report
  • c.The inspection report✓
  • d.The certification

Section 8516 states that the report shall be delivered before work is commenced on any property.

Reporting and Recordkeeping

What kind of report is prepared for a first inspection requested for a particular purpose?

  • a.Supplemental report
  • b.Reinspection report
  • c.Original report✓
  • d.Completion notice

Section 1993 defines the original inspection report as the report of the first inspection made at the request of a specified party or for a specified purpose.

Reporting and Recordkeeping

A different buyer orders an inspection of the same house two months later. What kind of report is required?

  • a.A supplemental report
  • b.A new original report✓
  • c.No report
  • d.A reinspection report

Inspections for a different party, purpose or transaction are deemed new inspections needing an original report.

Reporting and Recordkeeping

A wall listed as inaccessible is later opened and inspected. Which report is issued?

  • a.Supplemental report✓
  • b.Limited report
  • c.New complete report
  • d.Reinspection report

A supplemental report covers inaccessible areas that have been made accessible, and may also correct or add to an earlier report.

Want these explained in order? Branch 3 Field Representative Exam — California Termite Study Guide, 2027 Edition — PDF + EPUB, $14.99 · 14-day refund →

Reporting and Recordkeeping

Which report checks whether recommended items have been completed?

  • a.Limited report
  • b.Reinspection report✓
  • c.Supplemental report
  • d.Activity report

A reinspection is an inspection of items previously listed on an original report to determine whether the recommendations have been carried out.

Reporting and Recordkeeping

After how long must any further inspection be a new original inspection?

  • a.Twelve months from the original inspection
  • b.Two full years from the original inspection
  • c.One month from the date of the original inspection
  • d.Four months from the original inspection✓

Section 8516 provides that after four months all inspections shall be original inspections and not reinspections.

Reporting and Recordkeeping

What is the most a company may charge for a reinspection?

  • a.Nothing; a reinspection must always be free
  • b.A fee set each year by the Board in its rules
  • c.Up to twice its original inspection price
  • d.No more than its original inspection price✓

A reinspection shall be performed for not more than the price of the company's original inspection.

Reporting and Recordkeeping

How soon must a reinspection be completed once ordered?

  • a.Within 30 business days
  • b.Within 10 business days✓
  • c.Within 24 hours
  • d.Within four months

The statute requires completion within 10 business days after a reinspection has been ordered.

Reporting and Recordkeeping

When is a company not required to perform a reinspection?

  • a.When the owner carried out the repairs personally
  • b.When the original report was only a limited report
  • c.When the property has been sold since the report
  • d.When it gave no estimate or bid for repairs✓

If no estimate or bid was given with the original report or afterwards, the company is not required to reinspect.

Reporting and Recordkeeping

How must a reinspection report identify itself?

  • a.It omits the inspector's name and licence
  • b.It carries a new property address and a new foundation diagram
  • c.It is labelled "Reinspection" and gives the original report's date✓
  • d.It is printed on coloured paper to stand out

Each reinspection is reported on the inspection report form, labelled as a reinspection, and identifies the original report by date.

Reporting and Recordkeeping

What does Section I of a separated report contain?

  • a.The estimate for repairs and the terms of the guarantee
  • b.Conditions likely to lead to infestation or infection, where no evidence was found
  • c.Areas that could not be inspected and need further inspection
  • d.Visible evidence of active infestation or infection, and resulting conditions✓

Section 1990 prescribes the wording: Section I covers visible evidence of active infestation, infection or conditions resulting from them.

Reporting and Recordkeeping

What does Section II of a separated report contain?

  • a.Conditions likely to lead to infestation or infection, with none visible✓
  • b.The guarantee terms and the reinspection fee
  • c.Areas recommended for further inspection because they were not accessible
  • d.Active infestations found in the subarea or the attic, with their extent

Section II items are conducive conditions where no visible evidence of infestation or infection was found.

Reporting and Recordkeeping

An inaccessible attic is listed on a separated report. How is it classed?

  • a.As a further inspection item✓
  • b.As a completed item needing no action
  • c.As a Section I item with active infestation
  • d.As a Section II item, likely to lead to infestation

Further inspection items are areas the inspector could not access, which cannot be defined as Section I or Section II.

Reporting and Recordkeeping

When must the company tell the customer that a separated report is available?

  • a.Only if a dispute arises later
  • b.When the report is ordered✓
  • c.At close of escrow
  • d.After all the recommended work is done

Section 8516(c) requires the company to inform the person ordering the report, at that time, that a separate report is available.

Want these explained in order? Branch 3 Field Representative Exam — California Termite Study Guide, 2027 Edition — PDF + EPUB, $14.99 · 14-day refund →

Reporting and Recordkeeping

A dispute arises because the customer was not told about the separated report. What must the company do?

  • a.Provide one within 24 hours, at no extra cost✓
  • b.Provide one within ten days, for a fee
  • c.Reinspect the property at no charge
  • d.Refund the inspection fee in full

The separate report is supplied within 24 hours of the request and no later than the next business day, without charge.

Reporting and Recordkeeping

May conditions likely to lead to infestation be described as "active" infestations?

  • a.Yes, in limited reports
  • b.Yes, if the owner agrees
  • c.No✓
  • d.Yes, always

Section 8516(e) says such conditions shall not be characterised as actual defects or active infestations, or as needing correction before certification.

Reporting and Recordkeeping

Which statement must appear in bold on every inspection report?

  • a.That the reader has a right to seek a second opinion✓
  • b.That fumigation is recommended
  • c.That the Board has approved the findings
  • d.That the company is the lowest bidder for the work proposed

The statutory notice explains that reports by different companies should list the same findings, that recommendations may vary, and that a second opinion may be sought.

Reporting and Recordkeeping

What must the report say about pesticides?

  • a.Only that the pesticides used are safe for people
  • b.Nothing, unless a fumigation is planned for the structure
  • c.Which pesticide or pesticides are proposed, as section 8538 requires✓
  • d.The price of each pesticide per gallon of dilution

The report carries the pesticide information set out in section 8538, including the product and active ingredient.

Reporting and Recordkeeping

Which of these must be shown on the report under Board regulation section 1990?

  • a.The licence number and signature of the inspecting licensee✓
  • b.The company's bank account number and its bonding details in full
  • c.The owner's signature and the date on which the owner signed
  • d.The inspector's date of birth, home address and home telephone

Section 1990 requires the licence number of the person inspecting and the signature of the Branch 3 licensee who made the inspection.

Reporting and Recordkeeping

What does the report state about a guarantee?

  • a.Whether one is given, its terms and its duration✓
  • b.Only the price charged for the guarantee
  • c.That all work is guaranteed for life
  • d.Nothing; guarantees are always oral

Section 8516(f) requires the report and any contract to state specifically when a guarantee is made, its terms and the period it covers.

Reporting and Recordkeeping

Within what time is the notice of work completed and not completed given to the owner?

  • a.10 business days after completing the work✓
  • b.Before work begins
  • c.5 working days after final payment
  • d.30 calendar days after completing all the work

Section 8518 requires the notice to be furnished to the owner or agent within 10 business days after the work is completed.

Reporting and Recordkeeping

What cost information does the completion notice contain?

  • a.The cost of the original inspection only, and no figures for repairs
  • b.Cost of completed work and estimated cost of work not completed✓
  • c.Only the total amount paid to date by the owner for all the work
  • d.The company's profit on the job and its cost of materials used

The notice states the cost of what was completed and an estimate for recommendations not completed.

Reporting and Recordkeeping

What must any letter or bill that mentions the presence or absence of wood-destroying pests do?

  • a.Refer to the inspection report✓
  • b.Be signed by the owner of the property
  • c.Be approved in advance by the Board
  • d.Be recorded with the county recorder

Section 8517 requires such documents to refer to the section 8516 report and to say which recommendations were or were not completed.

Reporting and Recordkeeping

What does a certification under section 8519 state when no infestation was found?

  • a.No evidence of active infestation or infection in visible, accessible areas✓
  • b.The structure meets the current building code
  • c.The structure is guaranteed free of all wood-destroying pests in every area
  • d.The roof is watertight and the plumbing sound

Certification wording is limited to evidence of active infestation or infection in the visible and accessible areas. It is not a guarantee of hidden areas.

Reporting and Recordkeeping

When must a company prepare a certification?

  • a.When the person who ordered the report requests it✓
  • b.Only after a whole-structure fumigation has been completed
  • c.On every inspection
  • d.Only when the Board orders it after a complaint

Section 8519 obliges a company that made the inspection report to certify if the person ordering the report asks.

Reporting and Recordkeeping

Some recommended repairs were not done. How is the certification worded?

  • a.Free of evidence of active infestation except as listed✓
  • b.Subject to the buyer's written approval
  • c.No certification of any kind can be issued
  • d.Free of all infestation, without exception

The statute provides wording certifying freedom from evidence in visible and accessible areas "except as follows", with the exceptions described.

Reporting and Recordkeeping

A Branch 1 company fumigates on a Branch 3 company's report. Within what time does it issue the fumigation certification?

  • a.Five working days after completing the fumigation✓
  • b.Before the tarpaulins are removed
  • c.Ten business days after the report is delivered
  • d.Thirty days after aeration is complete

Section 8519.5 requires the Branch 1 company to certify the address, date and target pest to the company that prepared the report within five working days.

Reporting and Recordkeeping

A company inspects without charge and the customer then declines the work. Must it still issue a report?

  • a.Yes✓
  • b.Only if pests were found
  • c.Only if the customer pays
  • d.No

Section 1996 requires a report whether or not the inspection was offered free. Failure to pay does not excuse a company that has commenced an inspection.

Reporting and Recordkeeping

The person who ordered an inspection refuses to pay. What must the company do about the report?

  • a.Destroy the report and the field notes
  • b.File it only with the Board, not the customer
  • c.Prepare and deliver it anyway✓
  • d.Withhold it until the fee is paid in full

Refusal to pay does not excuse a registered company from preparing and delivering the report.

Reporting and Recordkeeping

Which inspection report need not be filed with the Board or given to the owner?

  • a.One prepared for a tenant of the property
  • b.One prepared for a buyer during an escrow sale
  • c.One prepared for a lender on a refinance
  • d.One prepared for an attorney for litigation✓

Section 8516 exempts a report prepared for use by an attorney for litigation purposes from address filing and the filing fee.

Reporting and Recordkeeping

What does a completion tag show?

  • a.Firm name, completion date and the pesticide or method used✓
  • b.The date of the next scheduled inspection
  • c.The owner's name and telephone number
  • d.The price paid and the balance still owed on the contract

Section 1996.1 requires the firm's name, date of completion, trade name of any pesticide used, and active ingredient or method of treatment.

Reporting and Recordkeeping

Where is the completion tag posted?

  • a.In the company's office file
  • b.On the roof by the vent
  • c.At the kerb
  • d.Next to the inspection tag✓

The completion tag is posted beside the inspection tag in the attic, subarea or garage.

Reporting and Recordkeeping

What must the report say about the inspection tag?

  • a.What colour it is printed in
  • b.Where it is located✓
  • c.Who printed it
  • d.Nothing about the tag at all

Section 1996.1 requires the inspection report to indicate the location of the inspection tag.

Reporting and Recordkeeping

A control service agreement must meet which requirement?

  • a.It covers every pest known to infest the building
  • b.It is in writing and signed by both parties✓
  • c.It is filed with the county recorder within ten days
  • d.It is oral and renewed automatically each year

Section 8516(h) requires a written agreement signed by both parties that states the pests and organisms covered.

Reporting and Recordkeeping

Under a control service agreement, must a full report be issued after every control service inspection?

  • a.Yes, within 10 business days
  • b.No✓
  • c.Yes, but only for drywood termites
  • d.Yes, within 24 hours

The company refers to the original report. If no written modification is made, conditions are assumed to be as originally reported.

Reporting and Recordkeeping

What must a control service contract state specifically?

  • a.The resale value of the house being covered
  • b.The brand of sprayer and the nozzle used
  • c.The pests covered and the portions of the building covered✓
  • d.The applicator's name, licence number and home address

Section 8516(g) requires the contract to name the particular wood-destroying pests or organisms and the parts of the structure covered.

Reporting and Recordkeeping

The owner chooses not to correct a reported condition. What is the company's position?

  • a.It is not liable for damage from that failure, absent negligence or fraud✓
  • b.It is liable for any later damage, whatever the cause
  • c.It must do the work without charge within ten business days of the report
  • d.It must withdraw the report

Section 8516(d) protects the company where the owner declines correction, but not from negligence, fraud or contractual obligations.

Reporting and Recordkeeping

What is the Notice to Owner that Branch 3 companies give under section 8513?

  • a.A notice of licence suspension by the Board
  • b.A notice of pesticide use and re-entry
  • c.A notice of re-entry after a fumigation
  • d.A notice about mechanics lien rights✓

Section 1937.16 prescribes the Notice to Owner explaining that unpaid contractors, subcontractors and suppliers may claim a lien on the property.

Reporting and Recordkeeping

Which form number is the standard inspection report?

  • a.43M-44
  • b.43M-41✓
  • c.43M-52
  • d.43M-47

Section 1996 identifies Form 43M-41 as the wood-destroying pests and organisms inspection report. Form 43M-44 is the completion notice and 43M-52 the activity report.

Planning

Drywood termite evidence extends into wall voids that cannot be reached. Which recommendation meets the regulation?

  • a.A surface spray of the exposed framing in the attic
  • b.An all-encompassing treatment such as fumigation✓
  • c.Removal of the pellets only
  • d.A reinspection in four months

Section 1991 says that when evidence indicates wood-destroying pests extend into inaccessible areas, the recommendation is fumigation, another all-encompassing method, or local treatment by exposing or removing the infested wood.

Planning

Which statement must accompany any recommendation for local treatment?

  • a.Local treatment replaces all future inspections of the whole structure
  • b.Local treatment is required by the building code in every California city
  • c.Local treatment is not intended to be an entire structure treatment✓
  • d.Local treatment is guaranteed for as long as the building stands

Section 1991 prescribes wording warning that infestations beyond the treated area may not be exterminated.

Planning

What does "all-encompassing treatment" mean in the regulation?

  • a.A method that treats only the accessible attic and subarea timbers
  • b.A soil treatment around the whole foundation
  • c.A method that treats the whole structure, such as fumigation✓
  • d.A coat of paint on exposed wood

The regulation refers to enclosing the structure for treatment with a fumigant, or another method that exterminates the infestation of the structure.

Planning

May a Branch 3 company recommend and contract for fumigation?

  • a.Yes, if it subcontracts the work in writing to a Branch 1 company✓
  • b.Yes, and it may fumigate itself under its Branch 3 registration
  • c.No, it may not mention fumigation in its report
  • d.Yes, but only for subterranean termites

Section 8514 lets a company recommend a method outside its branch if it subcontracts performance in writing to a company registered for that method.

Planning

What must the consumer give before fumigation work is subcontracted?

  • a.Oral consent
  • b.Written consent✓
  • c.A deposit of half the price
  • d.Nothing in writing at all

Section 8514(e) bars subcontracting structural fumigation without the consumer's written consent, after written advance notice of the right to choose another company.