Chapter 5 of 7
Texas Accessibility Standards
Public buildings in Texas follow the 2012 Texas Accessibility Standards (TAS), administered by the Texas Department of Licensing and Regulation. The plumber sets fixture heights, centrelines and blocking at rough-in, so the dimensions matter long before the trim goes on.
Water closets and compartments
The accessible water closet sits 16 to 18 inches from the side wall with a seat 17 to 19 inches high, the flush control on the open side, and grab bars on the side and rear walls.
Centreline
16 to 18 inches from the side wall.
2012 TAS §604.2Seat height
17 to 19 inches.
2012 TAS §604.4Clearance
60 inches from the side wall, 56 inches from the rear wall.
2012 TAS §604.3Grab bars
Side 42 inches, rear 36 inches; 33 to 36 inches high; 1-1/2 inches off the wall; 250 pounds.
2012 TAS §§604.5, 609Compartments
60 inches wide; 56 inches deep for wall-hung and 59 inches for floor-mounted water closets.
2012 TAS §604.8.1.1Ambulatory compartment
Added where six or more water closets and urinals are provided.
2012 TAS §213.3.1Lavatories, urinals and drinking fountains
Lavatory rims are 34 inches maximum with knee clearance beneath and protected pipes. Faucets work with one hand and no more than 5 pounds of force.
Lavatory rim
34 inches maximum.
2012 TAS §606.3Knee clearance
27 inches high at the front.
2012 TAS §306.3Exposed pipes
Insulated or configured to protect against contact.
2012 TAS §606.5Metering faucets
Stay open at least 10 seconds.
2012 TAS §606.4Urinal rim
17 inches maximum.
2012 TAS §605.2Drinking fountain
Spout 36 inches maximum; flow at least 4 inches high.
2012 TAS §602Showers and room layout
An accessible toilet room contains a 60-inch turning space and a 30 by 48 inch clear floor space at each fixture.
Transfer shower
36 by 36 inches.
2012 TAS §608.2.1Roll-in shower
30 by 60 inches minimum; threshold 1/2 inch maximum.
2012 TAS §§608.2.2, 608.7Spray unit
Hose at least 59 inches; water 120°F maximum.
2012 TAS §608.6Reach range
15 to 48 inches for an unobstructed forward reach.
2012 TAS §308.2.1