Texas Master Plumber Exam — All Questions
30 questions
In Texas, the Texas Accessibility Standards are administered by:
- a.The Texas Commission on Environmental Quality field office
- b.The Texas State Board of Plumbing Examiners
- c.The Railroad Commission of Texas
- d.The Texas Department of Licensing and Regulation✓
The Architectural Barriers programme of the Texas Department of Licensing and Regulation administers the Texas Accessibility Standards under Government Code Chapter 469.Tex. Gov't Code Ch. 469; 2012 TAS §101
Under TAS §604.2, the centreline of a wheelchair accessible water closet must be how far from the side wall or partition?
- a.10 to 12 inches
- b.16 to 18 inches✓
- c.30 to 36 inches
- d.22 to 24 inches
The water closet centreline is 16 inches minimum and 18 inches maximum from the side wall or partition; ambulatory accessible compartments use 17 to 19 inches.2012 TAS §604.2
Under TAS §604.4, the seat of an accessible water closet for adults must be how high above the finish floor, measured to the top of the seat?
- a.12 to 14 inches
- b.21 to 24 inches
- c.17 to 19 inches✓
- d.26 to 30 inches
The seat height is 17 inches minimum and 19 inches maximum, which matches a wheelchair seat for transfer. Seats may not be sprung to return to a lifted position.2012 TAS §604.4
Under TAS §604.3, the clearance around an accessible water closet must be at least 60 inches measured perpendicular from the side wall, and at least how deep measured from the rear wall?
- a.56 inches✓
- b.96 inches
- c.30 inches
- d.42 inches
Clearance around the water closet is 60 inches minimum from the side wall and 56 inches minimum from the rear wall.2012 TAS §604.3.1
Under TAS §609.4, grab bars at a water closet are mounted with the top of the gripping surface how high above the finish floor?
- a.18 to 24 inches
- b.33 to 36 inches✓
- c.54 to 60 inches
- d.42 to 48 inches
Grab bars are installed horizontally, 33 inches minimum and 36 inches maximum above the finish floor to the top of the gripping surface.2012 TAS §609.4
Under TAS §604.5.1, the side wall grab bar at a water closet must be at least how long?
- a.24 inches
- b.12 inches
- c.42 inches✓
- d.72 inches
The side wall grab bar is 42 inches long minimum, located 12 inches maximum from the rear wall and extending 54 inches minimum from the rear wall.2012 TAS §604.5.1
Under TAS §604.5.2, the rear wall grab bar at a water closet must generally be at least how long?
- a.18 inches
- b.36 inches✓
- c.12 inches
- d.60 inches
The rear wall grab bar is 36 inches long minimum, extending from the centreline of the water closet 12 inches minimum on one side and 24 inches minimum on the other.2012 TAS §604.5.2
Under TAS §609.3, the space between a grab bar and the wall must be:
- a.1/4 inch
- b.1-1/2 inches✓
- c.6 inches
- d.3-1/2 inches
The space between the wall and the grab bar is 1-1/2 inches, wide enough for a grip but too narrow for an arm to slip through and be trapped.2012 TAS §609.3
Under TAS §609.8, a grab bar and its mounting must withstand a vertical or horizontal force of at least:
- a.1,000 pounds
- b.50 pounds
- c.250 pounds✓
- d.100 pounds
Allowable stresses may not be exceeded when a force of 250 pounds is applied at any point on the grab bar, fastener, mounting device or supporting structure. Blocking in the wall has to be planned at rough-in.2012 TAS §609.8
Under TAS §604.6, the flush control of an accessible water closet must be located:
- a.On the side nearest the wall
- b.On the rear wall behind the seat cover
- c.On the floor beside the bowl
- d.On the open side of the water closet✓
Flush controls are hand operated or automatic; hand-operated controls are on the open side of the water closet (except in ambulatory compartments) and within reach range.2012 TAS §604.6
Under TAS §604.8.1.1, a wheelchair accessible toilet compartment with a wall-hung water closet must be at least:
- a.72 inches wide and 96 inches deep
- b.36 inches wide and 48 inches deep
- c.60 inches wide and 56 inches deep✓
- d.48 inches wide and 48 inches deep
Wheelchair accessible compartments are 60 inches wide minimum and 56 inches deep minimum for wall-hung water closets, or 59 inches deep for floor-mounted water closets.2012 TAS §604.8.1.1
Under TAS §213.3.1, where toilet compartments are provided and a toilet room has six or more water closets and urinals combined, the room needs a wheelchair accessible compartment and also:
- a.At least one ambulatory accessible compartment✓
- b.At least two family or assisted-use toilet rooms
- c.At least one bidet for each sex
- d.At least four additional lavatories
Where six or more toilet compartments are provided, or the combination of urinals and water closets totals six or more, at least one ambulatory accessible compartment is required in addition to the wheelchair accessible one.2012 TAS §213.3.1
Under TAS §605.2, the rim of an accessible urinal may be no higher above the finish floor than:
- a.30 inches
- b.10 inches
- c.17 inches✓
- d.24 inches
Accessible urinals are the stall type or the wall-hung type with the rim 17 inches maximum above the finish floor, and at least 13-1/2 inches deep from the wall to the outer face of the rim.2012 TAS §605.2
Under TAS §213.3.3, where urinals are provided in a toilet room, an accessible urinal is required:
- a.Only where ten or more urinals are provided
- b.Where more than one urinal is provided in the room✓
- c.Only in rooms that serve assembly occupancies
- d.In every room, even where only one urinal is provided
Where more than one urinal is provided, at least one complies with the accessible urinal requirements. A room with a single urinal is not required to make it accessible.2012 TAS §213.3.3
Under TAS §606.3, the rim or counter surface of an accessible lavatory may be no higher above the finish floor than:
- a.34 inches✓
- b.28 inches
- c.44 inches
- d.40 inches
Lavatories and sinks are installed with the higher of the front rim or counter surface 34 inches maximum above the finish floor, with knee and toe clearance below.2012 TAS §606.3
Under TAS §606.5, water supply and drain pipes under an accessible lavatory must be:
- a.Made of plastic so that they cannot become hot
- b.Insulated or otherwise configured to protect against contact✓
- c.Concealed in the wall with no access provided for later repair
- d.Chrome plated and polished to a bright finish
Supply and drain pipes under lavatories and sinks are insulated or configured to protect against contact, and there are no sharp or abrasive surfaces under the fixture, because a wheelchair user's legs may have no sensation.2012 TAS §606.5
Under TAS §306.3, knee clearance beneath an accessible lavatory must be at least how high at the front edge?
- a.17 inches
- b.36 inches
- c.9 inches
- d.27 inches✓
Knee clearance is 27 inches high minimum above the finish floor at the front, reducing toward the back; toe clearance is 9 inches high.2012 TAS §306.3
Under TAS §606.4 and §309.4, the faucet on an accessible lavatory must be operable:
- a.Only by an electronic sensor, since manual faucets are not permitted
- b.With one hand, without tight grasping, pinching or twisting of the wrist, using no more than 5 pounds of force✓
- c.With two hands, by turning separate round knobs for the hot and the cold water, using no more than 15 pounds of force
- d.With a foot pedal mounted on the floor in front of the lavatory, since hand controls are not permitted
Operable parts work with one hand and do not require tight grasping, pinching or twisting of the wrist, and the force to activate is 5 pounds maximum. Lever, push and sensor faucets all qualify.2012 TAS §§309.4, 606.4
Under TAS §606.4, a hand-operated metering faucet on an accessible lavatory must remain open for at least:
- a.2 seconds
- b.90 seconds
- c.10 seconds✓
- d.45 seconds
Hand-operated metering faucets remain open for 10 seconds minimum, giving a user time to wash without re-activating the faucet repeatedly.2012 TAS §606.4
Under TAS §603.3, a mirror located above an accessible lavatory must have the bottom edge of its reflecting surface no higher above the finish floor than:
- a.54 inches
- b.60 inches
- c.40 inches✓
- d.30 inches
Mirrors above lavatories or countertops have the bottom edge of the reflecting surface 40 inches maximum above the finish floor; other mirrors are 35 inches maximum.2012 TAS §603.3
Under TAS §603.2.1 and §304.3, an accessible toilet room must contain a turning space, which may be a circle with a diameter of at least:
- a.60 inches✓
- b.30 inches
- c.48 inches
- d.96 inches
Turning space is a 60-inch diameter circle or a T-shaped space within a 60-inch square, and it may include knee and toe clearance under fixtures.2012 TAS §§304.3, 603.2.1
Under TAS §305.3, the clear floor space for a single wheelchair at a fixture is at least:
- a.24 inches by 36 inches
- b.60 inches by 96 inches
- c.18 inches by 24 inches
- d.30 inches by 48 inches✓
The clear floor or ground space is 30 inches minimum by 48 inches minimum, positioned for a forward or parallel approach to the element.2012 TAS §305.3
Under TAS §308.2.1, the unobstructed forward reach range for controls such as flush valves and faucets is between:
- a.30 and 60 inches above the finish floor
- b.6 and 30 inches above the finish floor
- c.36 and 72 inches above the finish floor
- d.15 and 48 inches above the finish floor✓
Where a forward reach is unobstructed, the high reach is 48 inches maximum and the low reach 15 inches minimum above the finish floor.2012 TAS §308.2.1
Under TAS §602.4, the spout outlet of a wheelchair accessible drinking fountain may be no higher above the finish floor than:
- a.36 inches✓
- b.43 inches
- c.24 inches
- d.48 inches
Spout outlets for wheelchair accessible drinking fountains are 36 inches maximum above the finish floor; fountains for standing persons are 38 to 43 inches.2012 TAS §§602.4, 602.7
Under TAS §602.6, the spout of a wheelchair accessible drinking fountain must provide a flow of water at least:
- a.4 inches high✓
- b.18 inches high
- c.12 inches high
- d.1/2 inch high
The spout provides a flow of water 4 inches high minimum, so that a cup can be placed under the stream.2012 TAS §602.6
Under TAS §608.2.1, a transfer-type shower compartment has clear inside dimensions of:
- a.36 inches by 36 inches✓
- b.48 inches by 72 inches
- c.30 inches by 30 inches
- d.24 inches by 24 inches
Transfer-type shower compartments are 36 inches by 36 inches measured at the centre points of opposing sides, with a 36-inch wide entry.2012 TAS §608.2.1
Under TAS §608.2.2, a standard roll-in shower compartment has clear inside dimensions of at least:
- a.48 inches wide by 96 inches deep
- b.30 inches wide by 60 inches deep✓
- c.36 inches wide by 36 inches deep
- d.24 inches wide by 36 inches deep
Standard roll-in type showers are 30 inches wide minimum by 60 inches deep minimum, with a 60-inch wide entry on the face of the compartment.2012 TAS §608.2.2
Under TAS §608.6, the shower spray unit in an accessible shower must have a hose at least how long?
- a.120 inches
- b.59 inches✓
- c.24 inches
- d.12 inches
A shower spray unit has a hose 59 inches long minimum that can be used as a fixed head and as a hand-held shower, with an on-off control with a non-positive shutoff.2012 TAS §608.6
Under TAS §608.6 and §607.6, shower and bathtub spray units in accessible bathing fixtures must deliver water that is no hotter than:
- a.90°F
- b.140°F
- c.160°F
- d.120°F✓
Bathtub and shower spray units deliver water that is 120°F maximum, protecting users who cannot move quickly away from hot water or cannot feel it.2012 TAS §§607.6, 608.6
Under TAS §608.7, the threshold of a roll-in shower compartment may be no higher than:
- a.1/2 inch✓
- b.2 inches
- c.6 inches
- d.4 inches
Thresholds in roll-in type shower compartments are 1/2 inch high maximum, bevelled as required for changes in level. A standard 2-inch or taller curb blocks a wheelchair.2012 TAS §608.7