Texas Master Plumber Exam — All Questions
25 questions
A potable water heating appliance is generally treated as a water heater, exempt from boiler construction rules, up to limits of:
- a.2,000,000 Btu/h, 1,200 gallons of storage and 250°F
- b.75,000 Btu/h, 50 gallons of storage and 180°F
- c.200,000 Btu/h, 120 gallons of storage and 210°F✓
- d.20,000 Btu/h, 12 gallons of storage and 140°F
Above 200,000 Btu/h input, a water temperature of 210°F or a nominal capacity of 120 gallons, the vessel falls under boiler and pressure vessel rules, including ASME construction.ASME Boiler and Pressure Vessel Code, Section IV (exemption limits); IPC §504
Under IPC §504.3, a relief valve on a water heater must be:
- a.Of the manual type, opened weekly by the occupant
- b.Of the automatic self-closing type, tested to ANSI Z21.22✓
- c.Of the rupture-disc type, replaced after each discharge it makes
- d.Of the fusible-plug type only, with no pressure element
Relief valves are listed, self-closing and comply with ANSI Z21.22; a combination temperature and pressure relief valve protects against both conditions.IPC §504.3
Under IPC §504.5, the pressure relief setting of a water heater relief valve may not exceed the tank's rated working pressure or:
- a.150 psi, whichever is less✓
- b.80 psi, whichever is less
- c.300 psi, whichever is less
- d.500 psi, whichever is less
The relief valve is set to open at not more than the tank working pressure or 150 psi, whichever is less. Eighty psi is the static pressure limit that triggers a pressure-reducing valve.IPC §504.5
The temperature-sensing element of a temperature relief valve must be located, under IPC §504.5:
- a.In the cold water inlet pipe, upstream of the shutoff valve
- b.In the bottom 6 inches of the tank, next to the drain valve
- c.In the top 6 inches of the tank, in contact with the hottest water✓
- d.In the relief discharge pipe, near its termination point
The valve or its sensing element is installed in the shell within the top 6 inches of the tank so that it senses the hottest water. A valve on the cold inlet would never see the dangerous temperature.IPC §504.5
Under IPC §504.6, the relief valve discharge pipe may NOT:
- a.Discharge to an indirect waste receptor
- b.Have a valve or tee installed in it✓
- c.Be made of copper or CPVC pipe
- d.Be the same size as the valve outlet
The discharge pipe is full size, serves one relief device, has no valves or tee fittings, is not trapped, flows by gravity and ends through an air gap. Listed copper and CPVC are accepted materials.IPC §504.6
A relief valve discharge pipe terminates over a floor drain. Under IPC §504.6, the end of the pipe must be no more than how far above the floor or waste receptor flood level rim?
- a.48 inches
- b.6 inches✓
- c.1/2 inch
- d.24 inches
The pipe ends not more than 6 inches above the floor or receptor flood level rim and not less than two pipe diameters above it, and the end is not threaded.IPC §504.6
A bottom-fed storage water heater is supplied from a cold line that could be drained. Under IPC §504.2, the heater needs:
- a.A vacuum relief valve✓
- b.A flow control valve set
- c.A backwater valve
- d.A second drain valve
Bottom-fed water heaters and bottom-fed tanks connected to water heaters have a vacuum relief valve complying with ANSI Z21.22, so the tank cannot be siphoned dry and collapse or overheat.IPC §504.2
Under IPC §504.7.1, the drain pipe from a water heater pan must be at least:
- a.2 inches
- b.1/4 inch
- c.3/4 inch✓
- d.3 inches
The pan is drained by an indirect waste pipe of not less than 3/4 inch. A smaller drain cannot keep up with a leaking tank.IPC §504.7.1
A water heater is replaced in an existing building where no pan drain was installed. Under IPC §504.7.2, the pan:
- a.Must be omitted, because a pan without a drain is prohibited
- b.Must be piped into the relief valve discharge pipe
- c.May be left without a drain line to an approved location✓
- d.Must be piped into the heater's flue vent connector
Where a pan drain was not previously installed, a pan drain is not required for a replacement water heater installation. Connecting the pan to the relief line or the vent is never permitted.IPC §504.7.2
Under IPC §501.3, every storage water heater must have a drain valve that is:
- a.Installed on the relief valve outlet, with a locking handle
- b.Installed at the bottom of the heater, conforming to ASSE 1005✓
- c.Installed at the top of the heater tank, conforming to ASSE 1016
- d.Installed on the gas supply, upstream of the sediment trap
Drain valves for emptying the tank are at the bottom of each tank-type heater and hot water storage tank and conform to ASSE 1005.IPC §501.3
Under IPC §503.1, a cold water shutoff valve for a water heater must be:
- a.Installed on the cold supply near the heater, of the full-open type✓
- b.Omitted where the heater is smaller than 50 gallons
- c.Installed in the relief valve discharge line, of the quarter-turn ball type
- d.Installed on the hot outlet only, of the globe type
A full-open valve on the cold water branch near the equipment lets the heater be isolated for service without shutting off the building.IPC §503.1
A water heater is installed in an attic. Under IPC §502.3, the passageway to it must be large enough to remove the heater, at least 30 inches high and 22 inches wide, and not longer than:
- a.75 feet from the opening to the heater
- b.20 feet from the opening to the heater✓
- c.5 feet from the opening to the heater
- d.150 feet from the opening to the heater
The attic passageway is not more than 20 feet long measured along its centreline, has solid flooring at least 24 inches wide, and ends at a level service space of 30 by 30 inches.IPC §502.3
Under IFGC §305.3, a gas water heater with an ignition source that is installed in a garage must have that source elevated above the floor by at least:
- a.48 inches, unless the garage has a floor drain within 5 feet
- b.6 inches, unless the appliance is listed as flammable vapour ignition resistant
- c.18 inches, with no exception for any type of listed appliance
- d.18 inches, unless the appliance is listed as flammable vapour ignition resistant✓
Ignition sources are elevated 18 inches above the floor in hazardous locations and private and public garages, except for appliances listed as flammable vapour ignition resistant.IFGC §305.3
A gas water heater sits in the path of vehicles in a garage. Under IFGC §303.4, it must be:
- a.Painted with yellow stripes
- b.Protected from vehicle impact✓
- c.Converted to electric power first
- d.Vented with single-wall pipe
Appliances located where they may be subject to mechanical damage are protected by barriers, elevation or location out of the vehicle path.IFGC §303.4; §305.5
Under IFGC §303.3, a gas-fired water heater may NOT be installed in a bedroom or bathroom unless it is:
- a.Mounted at least 18 inches above the floor on a listed appliance stand, with a drain pan and a seismic strap fitted
- b.A direct-vent appliance, or in a dedicated enclosure with a self-closing weather-stripped door and outdoor combustion air✓
- c.A draft-hood appliance connected to a masonry chimney with a clay tile liner and a listed cap
- d.Rated at less than 100,000 Btu/h and fitted with an automatic vent damper
Appliances are kept out of sleeping rooms, bathrooms, toilet rooms and storage closets, with exceptions for direct-vent appliances and for appliances in a sealed enclosure that takes all combustion air from outdoors.IFGC §303.3
A draft-hood water heater takes all combustion air from inside the building. Under IFGC §304.5.1, the standard method requires a room volume of at least:
- a.5 cubic feet per 1,000 Btu/h of input
- b.50 cubic feet per 1,000 Btu/h of input✓
- c.500 cubic feet per 1,000 Btu/h of input
- d.1,000 cubic feet per 1,000 Btu/h of input
The standard method requires 50 cubic feet of indoor volume per 1,000 Btu/h of total appliance input; rooms with less volume are confined and need openings or outdoor air.IFGC §304.5.1
A 100,000 Btu/h gas water heater draws combustion air from outdoors through two vertical ducts. Under IFGC §304.6.1, each opening must have a free area of at least:
- a.25 square inches✓
- b.50 square inches
- c.100 square inches
- d.10 square inches
With direct or vertical-duct communication to outdoors, each of the two openings has 1 square inch per 4,000 Btu/h: 100,000 ÷ 4,000 = 25 square inches. Horizontal ducts need 1 square inch per 2,000 Btu/h, which would be 50.IFGC §304.6.1
A Category I gas water heater is connected to a vent with a single-wall metal connector. Under IFGC §503.10.5, a single-wall connector from a listed draft-hood appliance needs a clearance to combustibles of:
- a.36 inches
- b.6 inches✓
- c.18 inches
- d.1 inch
Single-wall connectors on listed appliances with draft hoods need 6 inches of clearance to combustible material; listed Type B vent material needs the clearance stated in its listing, typically 1 inch.IFGC §503.10.5
Under IFGC §503.10.9, the horizontal run of an uninsulated single-wall vent connector for a draft-hood appliance should not exceed:
- a.200 percent of the height of the chimney or vent
- b.10 percent of the height of the chimney or vent
- c.75 percent of the height of the chimney or vent✓
- d.400 percent of the height of the chimney or vent
The maximum horizontal length of a single-wall connector is 75 percent of the vent height (100 percent for a listed Type B double-wall connector), unless the system is engineered.IFGC §503.10.9
Under IFGC §503.6.5, a Type B gas vent serving a single draft-hood water heater must terminate at least how far in vertical height above the highest connected draft hood?
- a.5 feet✓
- b.15 feet
- c.1 foot
- d.30 feet
A Type B or L vent terminates at least 5 feet in vertical height above the highest connected appliance draft hood or flue collar, which gives enough draft.IFGC §503.6.5
The terminal of a direct-vent water heater with an input of 60,000 Btu/h must, under IFGC §503.8, be located at least how far from any air opening into the building?
- a.12 inches✓
- b.36 inches
- c.6 feet
- d.10 feet
Direct-vent terminal clearance from air openings is 6 inches for appliances up to 10,000 Btu/h, 9 inches up to 50,000 Btu/h and 12 inches above 50,000 Btu/h.IFGC §503.8
A mechanical-draft (power vent) water heater terminates through a side wall. Under IFGC §503.8, the terminal must be at least how far above any forced-air inlet located within 10 feet?
- a.30 feet
- b.15 feet
- c.3 inches
- d.3 feet✓
A mechanical draft venting system terminates at least 3 feet above any forced-air inlet within 10 feet, and at least 4 feet below, 4 feet horizontally from or 1 foot above doors, operable windows and gravity inlets.IFGC §503.8
A condensing (Category IV) gas water heater is vented with plastic pipe. Under IFGC §503.4.1, the plastic pipe and fittings must be:
- a.Any Schedule 40 drainage pipe that is available at the job site
- b.Solvent-cemented without primer, so that the joints stay flexible
- c.Those specified by the appliance manufacturer's installation instructions✓
- d.Cellular-core pipe, because its wall insulates the flue gases
Plastic vent piping for appliances follows the appliance manufacturer's instructions, including approved materials and primer where required. Cellular-core pipe is commonly excluded by manufacturers.IFGC §503.4.1
An electric water heater is installed. Besides the plumbing code, IPC §502.1 requires the electrical work to follow:
- a.NFPA 13D, with a sprinkler head over the heater
- b.NFPA 70, with a disconnecting means for the heater✓
- c.NFPA 54, with a sediment trap at the heater
- d.NFPA 99, with a zone valve box at the heater
Electric water heaters are installed per the manufacturer and the electrical code, NFPA 70, which requires a disconnect within sight or capable of being locked open.IPC §502.1
A closed water system is created when a backflow preventer is installed on the water service. Under IPC §607.3, the water heater system must then have:
- a.A device to control thermal expansion, such as an expansion tank✓
- b.A vacuum breaker on the cold inlet, upstream of the shutoff
- c.A larger gas supply, to offset the added pressure in the tank
- d.A second temperature and pressure relief valve on the hot outlet
Where a check valve, backflow preventer or pressure-reducing valve prevents expansion back into the main, a thermal expansion tank or other approved device controls the pressure rise. The relief valve is a safety device, not an expansion control.IPC §607.3