Texas Tradesman Plumber-Limited Exam Practice Test
Sample practice questions
A few real questions from this free bank, with full explanations. Use the practice tool above for the whole set.
- 1. Plumbing License Law and Board Rules
Under Occupations Code §1301.002, a Tradesman Plumber-Limited license holder may construct and install plumbing in:
- a.Apartment buildings and small offices
- b.Any building up to three stories high
- c.One-family and two-family dwellings only
- d.Any building outside a city's limits
Answer: c
Explanation: The statute limits the tradesman license to one-family and two-family dwellings. Apartments, offices and other commercial buildings need a journeyman or master plumber.
Source: Tex. Occ. Code §1301.002(10)
- 2. Plumbing License Law and Board Rules
A tradesman plumber-limited moves to a new home address. Under 22 TAC §365.8, the Board must be notified within:
- a.1 year
- b.24 hours
- c.30 days
- d.6 months
Answer: c
Explanation: License holders and registrants tell the Board of a change of name or address within 30 days, so that renewal and enforcement notices reach them.
Source: 22 TAC §365.8
- 3. General Requirements and Fixtures
A trench for a building sewer runs parallel to a house footing. Under IRC §P2604.4, the trench may not extend below:
- a.A 10-degree bearing plane from the top edge of the footing
- b.The finished grade line at the outside face of the footing
- c.The top of the foundation wall above the footing
- d.A 45-degree bearing plane from the bottom edge of the footing
Answer: d
Explanation: Trenching parallel to footings and walls does not extend into the bearing plane of the footing, taken as a 45-degree line from its bottom edge, so that the footing is not undermined.
Source: IRC §P2604.4
- 4. General Requirements and Fixtures
Under IRC §P2720.1, a whirlpool bathtub with a circulation pump needs:
- a.A dedicated water heater of at least 80 gallons
- b.A second overflow outlet at the opposite end
- c.An access opening to the pump, sized for removal and repair
- d.A floor drain under the bathtub, trapped and vented to the open air
Answer: c
Explanation: Access is provided to circulation pumps in accordance with the manufacturer's instructions; where none are given, an opening at least 12 by 12 inches is provided, larger where the pump is far from the opening.
Source: IRC §P2720.1
- 5. Water Heaters
Under IRC §P2801.2, every storage water heater must have a drain valve located:
- a.On the gas supply pipe
- b.At the top of the tank
- c.At the bottom of the tank
- d.On the hot water outlet pipe
Answer: c
Explanation: Water heaters have a drain valve at the bottom of the tank for flushing sediment and emptying the tank for service or replacement.
Source: IRC §P2801.2
- 6. Water Supply and Distribution
Under IRC §P2903.10, a hose bibb exposed to freezing that is not a frost-proof type must have:
- a.A trap primer in the supply line
- b.A cleanout plug at the outlet
- c.A pressure-reducing valve at the wall outlet
- d.A stop-and-waste valve inside the building
Answer: d
Explanation: Hose bibbs subject to freezing have a stop-and-waste type valve inside the building so they can be shut off and drained in cold weather; frost-proof hose bibbs whose stem reaches into the heated space are excepted.
Source: IRC §P2903.10
- 7. Sanitary Drainage
Under IRC §P3005.3, a horizontal drain pipe 2 inches in diameter must slope at not less than:
- a.3 inches per foot
- b.1/32 inch per foot
- c.1 inch per foot
- d.1/4 inch per foot
Answer: d
Explanation: Horizontal drainage piping 2-1/2 inches or less in diameter is installed at a uniform slope of not less than 1/4 inch per foot.
Source: IRC §P3005.3
- 8. Sanitary Drainage
Under IRC §P3008.1, a backwater valve is required for fixtures whose flood level rims are:
- a.More than 42 inches above the finished floor of the room
- b.Within 5 feet of the building's water service entrance
- c.Below the elevation of the manhole cover of the next upstream manhole
- d.Above the elevation of the manhole cover of the next upstream manhole
Answer: c
Explanation: Where fixture flood level rims are below the next upstream manhole cover in the public sewer, the fixtures are protected by a backwater valve. Fixtures above that level do not discharge through it.
Source: IRC §P3008.1
- 9. Vents and Traps
Under IRC §P3105.2, the total fall in a fixture drain from the trap weir to the vent fitting may not exceed:
- a.Four pipe diameters
- b.Six pipe diameters
- c.Ten pipe diameters
- d.One pipe diameter
Answer: d
Explanation: If the trap arm falls more than one pipe diameter, the top of the pipe at the vent drops below the trap weir and the arm can run full and siphon the trap.
Source: IRC §P3105.2
- 10. Fuel Gas Piping
New gas piping in a house is pressure tested. Under IRC §G2417.4.1, the test pressure must be at least 1-1/2 times the working pressure and not less than:
- a.1/4 psig
- b.3 psig
- c.60 psig
- d.150 psig
Answer: b
Explanation: The test pressure is not less than 1-1/2 times the proposed maximum working pressure and never less than 3 psig.
Source: IRC §G2417.4.1 (IFGC §406.4.1)