Load & DesignPregunta 18 de 110
Under California energy standards, duct leakage in many new and altered systems must be verified by which method?
a.Visual inspection only
b.A duct leakage (pressurization) test by a certified rater or installer
c.A refrigerant pressure test
d.A combustion analysis
Explicación
Title 24 requires duct leakage testing for many new installations and changeouts, typically verified through a pressurization test. Sealing ducts reduces energy waste and improves delivered airflow. Results are often confirmed by a HERS rater.
Referencia Legal: California Energy Code (Title 24)Practica las 110 preguntas gratis — sin registro.
Preguntas relacionadas de este tema
- Friction rate in duct design is typically expressed in which units?
- Air velocity in a duct is calculated by dividing airflow (CFM) by what?
- A branch duct must deliver 200 CFM at a velocity of about 600 feet per minute. Approximately what free area is required?
- Which condition would a technician correct by performing an accurate load calculation instead of using a rule of thumb like square footage per ton?
- Latent load in a cooling calculation refers to the energy required to do what?
- A 3-ton system is selected for a home. At 400 CFM per ton, what is the target blower airflow?
Última revisión: · proceso editorial
Equipo Editorial de PrepPass · Verificado con California CSLB C-20 Warm-Air HVAC Trade Exam · Cómo revisamos