Drainage, Waste & VentPregunta 10 de 120

A vent terminal passes through a roof that is used only for weather protection in an area with no snow-depth requirement. What is the minimum height the vent must extend above the roof surface?

a.3 in
b.6 in
c.12 in
d.24 in

Explicación

A vent through a roof used only for weather protection must extend at least 6 in above the roof. The 12 in dimension applies where the roof is used for any purpose other than weather protection, such as a deck or assembly area, and 3 in is below the minimum while 24 in exceeds what the code requires here.

Referencia Legal: UPC §906.1