Drainage, Waste & VentPregunta 8 de 120

Which trap arrangement is expressly prohibited because it will siphon its own seal?

a.An S-trap
b.A P-trap vented within the permitted trap arm length
c.A drum trap serving a specialty fixture where approved
d.A deep seal trap on a floor drain

Explicación

An S-trap discharges vertically downward with no vent break, so the falling column of water pulls the seal out of the trap and is prohibited. A properly vented P-trap is the standard approved arrangement, and drum traps and deep seal traps remain permitted in specific approved applications.

Referencia Legal: IPC §1002.1