A grease interceptor is inspected and found to contain accumulated grease and settled solids filling 25 percent of the total liquid depth. What action does the common maintenance standard require?
a.No action; cleaning is required only at 50 percent
b.Add an enzyme treatment and re-inspect in six months
c.Install a larger flow control device to slow the incoming flow
d.Pump and clean the interceptor, since the 25 percent threshold has been reached
Explicación
The widely used 25 percent rule requires that an interceptor be pumped when grease and solids occupy a quarter of the liquid depth, because beyond that point retention efficiency falls off sharply. Waiting for 50 percent allows grease carryover into the building drain. Enzyme or chemical treatments emulsify grease so it passes through the unit rather than being retained, and changing the flow control does not remove the accumulated material.
Referencia Legal: IPC §1003.3Practica las 120 preguntas gratis — sin registro.
Preguntas relacionadas de este tema
- A showerhead is rated at the maximum allowable flow. A user showers for 8 minutes. Assuming the head flows at its rated maximum, how much water is used?
- A public restroom is fitted with metering faucets. What is the maximum volume of water each faucet may deliver per metering cycle?
- A closet flange is set on a wood subfloor before the finished tile is installed, and the installer plans to seal the closet to the flange. Which practice is correct?
- A restaurant installs a grease interceptor sized for 30 minutes of retention. If the connected fixtures produce a peak flow of 25 gallons per minute through the flow control device, what liquid capacity does the retention rule call for?
- A residence has a pressure reducing valve with a check on the incoming water service, and the 40 gallon water heater's relief valve has begun weeping each evening. What is the most likely cause and the correct correction?
- A three compartment pot sink and a food prep sink are being connected in a commercial kitchen. How must the waste from food handling equipment such as a food prep sink be connected to the drainage system?
Última revisión: · proceso editorial
Equipo Editorial de PrepPass · Verificado con Journeyman Plumber Licensing Exam (UPC/IPC-based) · Cómo revisamos